Ademco Vista 21IP Programming
This is a version of the Vista-20p
[ 4-Wire Smoke ] |
|||
AVS 2-Way Module |
Note: Do this outside of Programming (V7 or highder) Installer code + [#] + 03: Enable AVS operation without panel sounds on the AVST Installer code + [#] + 04: Enable AVS operation and enable panel sounds on AVST Installer code + [#] + 05: Disable AVS operation without panel sounds on the AVST Installer code + [#] + 06: Disable AVS operation and enable panel sounds on AVST |
||
Enter Program |
4112 + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) |
||
Move to Location | * + Location | ||
View Location | # + Location (Display will read off one digit at a time) | ||
Exit Program | *98 OR *99 if needing to re-enter programming later by Code + 8 + 00 | ||
Timer Test |
Installer code + # + 00= Daily Installer code + # + 01= weekly Installer code + # + 02= Monthly * 64 Test Report code I_1_I_0_I |
|
||||||||||||||||||||||||||||||
*20 | Installer Code | I_4_I_1_I_1_I_2_I | ||||||||||||||||||||||||||||
*21 | Quick Arm Enable | I_1_I | 0 = No 1 = Yes | |||||||||||||||||||||||||||
*22 | RF Jam Option | I_0_I | 0 = None 1 = send RF Jam report | |||||||||||||||||||||||||||
*23 | Forced Bypass Enable | I_0_I | 0 = No 1 = Yes | |||||||||||||||||||||||||||
*24 | RF House Code | I_0_I_0_I Part 1 I_0_I_0_I Part 2 I_0_I_0_I Common |
00 = Disabled | |||||||||||||||||||||||||||
*26 | Chime by Zone | I_0_I_0_I |
(Entry 1) 0 = Disabled 1 = Enabled 2 = Comm Device Trouble Sounding 4 = System Low Bat Sounding 7 Select all Entry 1 Options (Entry 2) |
|||||||||||||||||||||||||||
*27 | X-10 House Code | I_0_I | 0 = A 1 = B 2 = C 3 = D 4 = E 5 = F 6 = G 7 = H 8 = I 9 = J #10 = K #11 = L #12 = M #13 = N #14 = O #15 = P |
|||||||||||||||||||||||||||
*28 | 4285/4286 Voice Module Access Code |
I_0_I_0_I | (Allows access to Voice module) 00 = Disabled 1st digit = 1 to 9 2nd digit = # + 11 for * or # + 12 for # |
|||||||||||||||||||||||||||
*29 | [ Menu Mode for IP/GSM Enable ] | |||||||||||||||||||||||||||||
*31 | Single Alarm Sounding/Zone | I_0_I | 0 = No (If 0, follows swinger suppression in *93) 1 = Yes |
|||||||||||||||||||||||||||
*32 | Fire Sounder Timeout | I_1_I | 0 = Timeout 1 = No Timeout |
|||||||||||||||||||||||||||
*33 | Alarm Bell Timeout | I_2_I | 0 = None 1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
|||||||||||||||||||||||||||
*34 | Exit Delay | I_6_I_0_I part 1 I_6_I_0_I part 2 |
45 – 96 = 45 – 96 Seconds 97 = 120 Seconds NOTE: Entries less than 45 seconds will result in a 45 second delay |
|||||||||||||||||||||||||||
*35 | Entry Delay #1 (Zone type 01) | I_3_I_0_I part 1 I_3_I_0_I part 2 |
30 – 96 = 30 – 96 Seconds 97 = 120 Seconds 98 = 180 Seconds 99 = 240 Seconds |
|||||||||||||||||||||||||||
*36 | Entry Delay #2 (Zone type 02) | I_6_I_0_I part 1 I_6_I_0_I part 2 | ||||||||||||||||||||||||||||
*37 | Audible Exit Warning | I_N/A_I | Feature always enabled. Cannot be disabled | |||||||||||||||||||||||||||
*38 | Confirmation of Arming Ding | I_0_I part 1 I_0_I part 2 |
0 = No 1 = Yes 2 = RF Only |
|||||||||||||||||||||||||||
*39 | Power Up in Previous State | I_0_I | 0 = No 1 = Yes | |||||||||||||||||||||||||||
*40 | PABX Access Code (Up to 6 digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I (If 9 is needed to dial add here) | ||||||||||||||||||||||||||||
*41 | Primary Phone (Up to 20 digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = *# + 12 = # # + 13 = 2 second pause |
||||||||||||||||||||||||||||
*42 | Secondary Phone (Up to 20 digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = *# + 12 = # # + 13 = 2 second pause |
||||||||||||||||||||||||||||
*43 | Partition 1 Primary Account # | I_ _I_ _I_ _I_ _I (Last 4 of Account) A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 |
||||||||||||||||||||||||||||
*44 | Partition 1 Secondary Account # | I_ _I_ _I_ _I_ _I | ||||||||||||||||||||||||||||
*45 | Partition 2 Primary Account # | I_ _I_ _I_ _I_ _I (Last 4 of Account) A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 |
||||||||||||||||||||||||||||
*46 | Partition 2 Secondary Account # | I_ _I_ _I_ _I_ _I | ||||||||||||||||||||||||||||
*47 | Phone System Select | I_3_I | 0 = Pulse Dial 1 = DTMF Dial 2 = Pulse Dial, CS on Watts Line 3 = DTMF Dial, CS on Watts Line |
|||||||||||||||||||||||||||
*48 | Report Format | I_07_I Primary I_07_I Secondary |
00 = 3/1, 4/1 Ademco L/S Standard 01 = 3/1, 4/1 Radionics Standard 02 = 4/2 Ademco L/S Standard 03 = 4/2 Radionics Standard 05 = 10-digit Contact ID 06 = 4/2 Ademco Express 07 = Contact ID 08 = 3/1, 4/1 Ademco L/S Expanded 09 = 3/1, 4/1 Radionics Expanded |
|||||||||||||||||||||||||||
*49 | Split/Dual Reporting |
I_0_I
|
||||||||||||||||||||||||||||
*50 | Burg Dialer Delay | I_2_II_0_I | Delay Time: 1 = 15 secs; 2 = 30 secs; 3 = 45 secs Delay Disable: 0 = use delay set in 1st digit 1 = dial delay disabled for zones listed in zone list 6 (Use zone list 6 to enter zones that need dial delay to be disabled; these zones ignore the setting in entry 1) |
|||||||||||||||||||||||||||
*53 | Sescoa/Radionics | I_0_I | 0 = No 1 = Yes |
|||||||||||||||||||||||||||
*54 | Dynamic Signaling Delay | I_0_I | 0 = No delay (Both signals sent) 1 = 15 seconds 2 = 30 seconds (etc) |
|||||||||||||||||||||||||||
*55 | Dynamic Signaling Priority | I_0_I | 0 = Primary Dialer First (Alarmnet is secondary) 1 = Long Range Radio First (Alarmnet is primary) |
|||||||||||||||||||||||||||
*56 | Zone Assignments | |||||||||||||||||||||||||||||
Hardwired | Zones 01 to (2-Wire Smokes Zone 1 only, 4-Wire can be 2 to 8) | |||||||||||||||||||||||||||||
4219/4229 Hardwire Expander |
Zones 09 to 16 or Zones 17 to 24 | |||||||||||||||||||||||||||||
Wireless | Zones 09 to 48 (Depending on capacity of 5881 receiver) | |||||||||||||||||||||||||||||
Keyfob Zones | Zones 49 to 56 | |||||||||||||||||||||||||||||
Duress | Zone 92 | |||||||||||||||||||||||||||||
Fire Panic | Zone 95 | |||||||||||||||||||||||||||||
Medical Panic | Zone 96 | |||||||||||||||||||||||||||||
Police Panic | Zone 99 | |||||||||||||||||||||||||||||
1. Keypad displays “Zone Prog?” press 1 | ||||||||||||||||||||||||||||||
2. “Enter Zn No.” enter which zone to program (01-56, 89-91, 95, 96, 97, 99) press * | ||||||||||||||||||||||||||||||
3. Keypad will show summary zones programming, press * | ||||||||||||||||||||||||||||||
4. “Zone Type?” Enter type then * |
00 = Zone Disabled/Deleted 01 = Delay Zone 02 = Secondary Delay Zone 03 = Perimeter/Instant 04 = Interior Follower/Motions 05 = Trouble by Day/Alarm by Night 06 = 24 hour Silent/Holdup 07 = 24 hour Police Panic 08 = 24 hour Aux/Medical 09 = Fire 10 = Interior Delay 12 = Monitor Zone 14 = Carbon Monoxide 16 = Fire w/Verification 20 = Arm-Stay (RF only) 21 = Arm-Away (RF only) 22 = Disarm (RF only) 23 = No Alarm Response 24 = Silent Burglary 77 = Keyswitch 81 = AAV Monitor 90 = Configurable Zone Type 1 * See section * 182 91 = Configurable Zone Type 2 * See section * 184 |
|||||||||||||||||||||||||||||
6. “Report Code?” enter 10 then * |
||||||||||||||||||||||||||||||
7. “Input Device?” Enter device then * |
01 = for Hardwired 02 = Auxiliary Wired (with 4219/4229 Expander) 03 = for Supervised RF (most sensors are RF) 04 = for Un-Supervised RF 05 = RF Button Type (Keyfobs/Panics etc) | |||||||||||||||||||||||||||||
8. Cursor should flash above the loop number “LP#”, Enter 1 to 4 depending on sensor | ||||||||||||||||||||||||||||||
Door Switch |
Loop 1 = External Sensor Connector Loop 2 = Internal Reed Switch |
|||||||||||||||||||||||||||||
Glassbreak | Loop 1 | |||||||||||||||||||||||||||||
Smoke Detectors | Loop 1 | |||||||||||||||||||||||||||||
Motions | Loop 1 | |||||||||||||||||||||||||||||
Keyfobs |
Loop 1 = Bottom Right Button (Each button counts as 1 zone) Loop 2 = Top Right Button Loop 3 = Top Left Button Loop 4 = Bottom Left Button |
|||||||||||||||||||||||||||||
9. “Learn Sensor Y/N?” | Press 1 and trip sensor twice (you cannot enter serial numbers) | |||||||||||||||||||||||||||||
10. “Alpha Program?” | Press 0 if not programming – [ Alpha Descriptors ] | |||||||||||||||||||||||||||||
11. “Keypad will show either new summary for zone or “Enter zone number” | ||||||||||||||||||||||||||||||
12. If finished programming enter 00 at “Enter zone no” to return to normal programming | ||||||||||||||||||||||||||||||
*57 | [ Function Key Programming ] – (6139 or 6160 Alpha Keypad required here) | |||||||||||||||||||||||||||||
(If altering function keys A B or C delete programming for zones 95, 99 or 96) | ||||||||||||||||||||||||||||||
Defaults | Function Key A Zone 95 | |||||||||||||||||||||||||||||
Function Key B Zone 99 | ||||||||||||||||||||||||||||||
Function Key C Zone 96 | ||||||||||||||||||||||||||||||
Function Key D Single Button Page | ||||||||||||||||||||||||||||||
1. Press Function Key to program | (A = Top to D = Bottom Function Key) | |||||||||||||||||||||||||||||
2. Display shows Function Key chosen | (* for next, # for previous menu) | |||||||||||||||||||||||||||||
3. Enter Partition of Function Key | (* for next, # for previous menu) | |||||||||||||||||||||||||||||
1 = Partition 1 | ||||||||||||||||||||||||||||||
2 = Partition 2 | ||||||||||||||||||||||||||||||
3 = Common Partition (Lobby) | ||||||||||||||||||||||||||||||
4. Choose Function for this Key | (* for next, # for previous menu) | |||||||||||||||||||||||||||||
00 = A Zone 95 B = Zone 99 C = Zone 96 D = Single Button Page |
01 = Single Button Page (sends 999-9999 message to Pager 02 = Display Time 03 = Arm Away 04 = Arm Stay 05 = Arm Night/Stay (any Zone in Zone List 5 *81 menu) 06 = Step Arming (Stay then Night/Stay then Away) 07 = Device A Activation (Type 66 Function in *80 menu) 08 = Communication Test 09 = Macro Key 1 (Activated by User Code + # + 66) 10 = Macro Key 2 (Activated by User Code + # + 66) 11 = Macro Key 3 (Activated by User Code + # + 66) 12 = Macro Key 4 (Activated by User Code + # + 66) |
|||||||||||||||||||||||||||||
5. Enter next Function Key or 0 to exit | ||||||||||||||||||||||||||||||
6. Press * or # to exit | ||||||||||||||||||||||||||||||
*58 | Expert Mode | |||||||||||||||||||||||||||||
Programming keys: | ||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
1. “Set to confirm?” | 0 = No, 1 = Yes | |||||||||||||||||||||||||||||
2. Summary of zone 1’s current programming. Enter 2-digit zone number and press *, 00 to quit | ||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||
Enter zone information and then * for next (A moves right, B moves left)
ZT = Zone Type |
||||||||||||||||||||||||||||||
3. If wireless goes to enter S/N if hardwired goes to the next zone | ||||||||||||||||||||||||||||||
*59 | Exit Error Report Code | I_1_I | SIA NOTE: Always enabled. | |||||||||||||||||||||||||||
*60 | Trouble Report Code | I_1_I_0_I | ||||||||||||||||||||||||||||
*61 | Bypass Report Code | I_0_I_0_I | ||||||||||||||||||||||||||||
*62 | AC Loss Report Code | I_1_I_0_I | ||||||||||||||||||||||||||||
*63 | Low Bat Report Code | I_1_I_0_I | ||||||||||||||||||||||||||||
*64 | Test Report Code | I_0_I_0_I | (Installer code + # + 0 + 2 outside programming to enable monthly) |
|||||||||||||||||||||||||||
*65 | Open Report Code |
| ||||||||||||||||||||||||||||
*66 | Away/Stay Report |
|
||||||||||||||||||||||||||||
*67 | RF Xmtr Low Bat | I_0_I_0_I | ||||||||||||||||||||||||||||
*68 | Cancel Report Code | I_1_I_0_I | ||||||||||||||||||||||||||||
*69 | Recent Close | I_1_I | SIA NOTE: Always enabled. | |||||||||||||||||||||||||||
*70 | Alarm Restore Code | I_0_I | (Must be enabled if using smoke) | |||||||||||||||||||||||||||
*71 | Trouble Restore Code | I_0_I_0_I | ||||||||||||||||||||||||||||
*72 | Bypass Restore Code | I_0_I_0_I | ||||||||||||||||||||||||||||
*73 | AC Restore Code | I_0_I_0_I | ||||||||||||||||||||||||||||
*74 | Low Bat Rest Code | I_0_I_0_I | ||||||||||||||||||||||||||||
*75 | RF Low Bat Rest Code | I_0_I_0_I | ||||||||||||||||||||||||||||
*76 | Test Restore Rpt Code | I_0_I_0_I | ||||||||||||||||||||||||||||
*77 | Daylight Sav Time Start/End Month |
I_3_I_11_I | 0 = Disabled 1 – 9 = January – September (1 = Jan, 2 = Feb, etc) #10 = October, #11 = November, #12 = December |
|||||||||||||||||||||||||||
*78 | Daylight Sav Time Start/End Weekend |
I_2_I_1_I | 0 = Disabled 1 = First 2 = Second 3 = Third 4 = Fourth 5 = Last 6 = Next to last 7 = Third to last |
|||||||||||||||||||||||||||
*79 | Output Device Mapping – [ Relay Programming ] | |||||||||||||||||||||||||||||
*80 | Output Programming – [ Relay Programming ] | |||||||||||||||||||||||||||||
*81 | Zone List Programming | |||||||||||||||||||||||||||||
*82 | Alpha Editing (Same as in *56) – [ Alpha Descriptors ] | |||||||||||||||||||||||||||||
*84 | Auto Stay Arm | I_0_I | 0 = Disabled, 1 = Part 1 only, 2 = Part 2 only, 3 = both |
|||||||||||||||||||||||||||
*85 | Cross Zone Timer | I_0_I |
|
|||||||||||||||||||||||||||
*86 | Cancel Verify Keypad Display | I_0_I | 0 = No “alarm cancelled” display 1 = Displays “alarm cancelled” when code + off is pressed |
|||||||||||||||||||||||||||
*87 | Misc. Fault Delay Time | I_0_I |
|
|||||||||||||||||||||||||||
*88 | Program Mode Lockout Option | I_0_I |
|
|||||||||||||||||||||||||||
*89 | Event Log 80% Full | I_0_I_0_I | ||||||||||||||||||||||||||||
*90 | Event Logging | I_15_I | 0 = None 1 = Alarm/Restore 2 = Trouble/Restore 4 = Bypass/Bypass Restore 8 = Open/Close |
|||||||||||||||||||||||||||
*91 | Option Selection | I_0_I I_0_I | 0 = None Options Call Waiting Disable 4 = AAV 8 = Exit Delay Restart |
|||||||||||||||||||||||||||
*92 | Phone Monitor Enable | I_0_I | (Panel MUST be properly grounded for this to work!) 0 = Not Used 1 = KP Disp 2 = KP Disp/Sounder 3 = KP Disp/Sounder/Dev 2 starts |
|||||||||||||||||||||||||||
*93 | Reports per Armed Period Per Zone |
I_0_I | 0 = Unlimited Reports per Armed period 1 = 1 report pair per armed period 2 = 2 report pairs per armed period |
|||||||||||||||||||||||||||
*94 | Download Phone Number | I_1_I_8_I_0_I_0_I_5_I_6_I_0_I_2_I_0_I_0_I_1_I_ _I | ||||||||||||||||||||||||||||
*95 | Ring Count | I_#15_I | 0 to #15 #15 = Answer Machine Defeat | |||||||||||||||||||||||||||
*96 | Reinitialize Download (No Value needed, keypad will just beep and resets CSID and Account number to F’s) | |||||||||||||||||||||||||||||
*97 | Default Panel (No Value needed, keypad will beep and default panel) | |||||||||||||||||||||||||||||
*98 | Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) | |||||||||||||||||||||||||||||
*99 | Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) | |||||||||||||||||||||||||||||
*160 | Pager 1 Phone No. | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Enter up to 20 digits. 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
||||||||||||||||||||||||||||
*161 | Pager 1 Characters | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Enter the optional additional prefix characters up to 16 digits 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
||||||||||||||||||||||||||||
*162 | Pager 1 Reporting Options |
|
||||||||||||||||||||||||||||
*163 | Pager 2 Phone No. | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Enter up to 20 digits. 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
||||||||||||||||||||||||||||
*164 | Pager 2 Characters | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Enter the optional additional prefix characters up to 16 digits 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
||||||||||||||||||||||||||||
*165 | Pager 2 Reporting Options |
|
||||||||||||||||||||||||||||
*166 | Pager 3 Phone No. | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Enter up to 20 digits. 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
||||||||||||||||||||||||||||
*167 | Pager 3 Characters | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Enter the optional additional prefix characters up to 16 digits 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
||||||||||||||||||||||||||||
*168 | Pager 3 Reporting Options |
|
||||||||||||||||||||||||||||
*169 | Pager 4 Phone No. | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Enter up to 20 digits. 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
||||||||||||||||||||||||||||
*170 | Pager 4 Characters | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Enter the optional additional prefix characters up to 16 digits 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
||||||||||||||||||||||||||||
*171 | Pager 4 Reporting Options |
|
||||||||||||||||||||||||||||
*172 | Pager Delay Option For Alarms | I_0_I | 0 = none, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes This delay is for ALL pagers in the system. NOTE: Delay does not reset for new alarms occurring while an existing pager delay is in progress. |
|||||||||||||||||||||||||||
*174 | Clean Me Reporting Option (For ESL smoke detectors) |
I_0_I | 0 = disable; 1 = Clean Me signal reports; Note: If Clean Me is enabled, you must enter “3” in field *56 programming for zone 1 response time. |
|||||||||||||||||||||||||||
*177 | Device Duration 1, 2 |
|
(Used in *80 Menu mode device action 5/6) | |||||||||||||||||||||||||||
0 = 15 seconds | 6 = 2 min | # + 11 = 7 min | ||||||||||||||||||||||||||||
1 = 30 seconds | 7 = 3 min | # + 12 = 8 min | ||||||||||||||||||||||||||||
2 = 45 seconds | 8 = 4 min | # + 13 = 10 min | ||||||||||||||||||||||||||||
3 = 60 seconds | 9 = 5 min | # + 14 = 12 min | ||||||||||||||||||||||||||||
4 = 90 seconds | # + 10 = 6 min | # + 15 = 15 min | ||||||||||||||||||||||||||||
5 = 2 minutes | ||||||||||||||||||||||||||||||
*181 | 50/60 Hertz AC Operation | I_0_I | 0 = 60 Hz; 1 = 50 Hz | |||||||||||||||||||||||||||
*182 | Configurable Zone Type 90 |
Enter the appropriate Value for each entry, 1-10, based on the links. |
||||||||||||||||||||||||||||
*183 | Zone Type 90 Report Codes (IMPORTANT: Use Existing CID Codes, if appropriate, or define Unique codes in CID code range 750-789.) | |||||||||||||||||||||||||||||
90 ALARM ID: XXX | TROUBLE ID: XXX | |||||||||||||||||||||||||||||
Enter the desired 3 digit CID report codes for alarms and troubles occurring on zones assigned to this zone type. Enter the codes sequentially (all 6 digits). When entering digits, [#] moves cursor back, [*] moves forward. Press [*] when done to continue. | ||||||||||||||||||||||||||||||
*184 | Configurable Zone Type 91 |
Enter the appropriate Value for each entry, 1-10, based on the links. |
||||||||||||||||||||||||||||
*185 | Zone Type 91 Report Codes (IMPORTANT: Use Existing CID Codes, if appropriate, or define Unique codes in CID code range 750-789.) | |||||||||||||||||||||||||||||
91 ALARM ID: XXX | TROUBLE ID: XXX | |||||||||||||||||||||||||||||
Enter the desired 3 digit CID report codes for alarms and troubles occurring on zones assigned to this zone type. Enter the codes sequentially (all 6 digits). When entering digits, [#] moves cursor back, [*] moves forward. Press [*] when done to continue. | ||||||||||||||||||||||||||||||
*189 | AUI Device Enables |
|
||||||||||||||||||||||||||||
*190 | Keypad 2 Device Address 17 | I_0_I I_0_I |
1st digit Partition:
0 = Keypad disabled; 2nd digit Sound: 0 = no suppression |
|||||||||||||||||||||||||||
*191 | Keypad 3 Device Address 18 | I_0_I I_0_I | See field *190 for entries. | |||||||||||||||||||||||||||
*192 | Keypad 3 Device Address 19 | I_0_I I_0_I | See field *190 for entries. | |||||||||||||||||||||||||||
*193 | Keypad 3 Device Address 20 | I_0_I I_0_I | See field *190 for entries. | |||||||||||||||||||||||||||
*194 | Keypad 3 Device Address 21 | I_0_I I_0_I | See field *190 for entries. | |||||||||||||||||||||||||||
*195 | Keypad 3 Device Address 22 | I_0_I I_0_I | See field *190 for entries. | |||||||||||||||||||||||||||
*196 | Keypad 3 Device Address 23 | I_0_I I_0_I | See field *190 for entries. | |||||||||||||||||||||||||||
*197 | Exit Time Display Interval | I_0_I | 0 = no display; 1-5 = sec between display Refresh | |||||||||||||||||||||||||||
*198 | Display Partition Number | I_0_I | For Alpha Displays Only 0 = No 1 = Yes (Partition # will display on Alpha Display) |
|||||||||||||||||||||||||||
*199 | ECP Fail Display | I_0_I | 0 = 3-digit display (“1” + device address) 1 = 2-digit fixed display as “91” |