Ademco 320P1 Basics

Zone 8 Hardwired, up to 40 Wireless, 16 Keyfob zones
Batteries
12 volt rechargeable inside main panel AC Transformer is 16 volts
Door/Windows 3-volt Lithium (Panasonic CR123A)
Motion Sensor 2 x 3-volt Lithium (Panasonic CR123A)
Smoke Detector 2 x 3-volt Lithium
Remote Keypads 9 Volt Alkaline
Keyfobs Changes based on Keyfob
Remote Panics Changes based on Remote
Partitions 2 Plus common partition
Downloadable Yes – Installer + # + 1 to send.
Panic Buttons Police Panic – * and #
Fire Panic – 1 and *
Medical Panic – 3 and #
Status Press * if keypad shows NOT READY to view open zones
Arm AWAY 4-digit code + 2 (AWAY)
Arm Stay 4-digit code + 3 (STAY) (Entry and Exit Delays are still active)
Disarm 4 digit code + 1 (OFF)
Quick-Arm Press # + 2 for AWAY, # + 3 for STAY
Instant Arm 4 digit code + 7 (INSTANT) Arms like stay but no entry delay (Exit delay is still active)
Sniffer Mode Installer code + # + 3, Exit with Installer Code + 1
This will Detect all wireless enrolled and display them on the screen.

Walk Test Master Code + 5 + 0
Comm Test Master Code + 5 + 1
Max Arming 4-digit code + 4 (MAX) to arm everything Instant (Exit delay is still active)
Silence Alarm 4-digit code + 1 (OFF) twice to turn off siren and reset display
(If code is entered wrong, wait 2 or 3 seconds then try again)
Door Chimes 4-digit code + 9 (CHIME)
Bypass 4-digit code + 6 (BYPASS) + zone (01, 02 03 etc)
Force Bypass 4-digit code + 6 (BYPASS) + # (If enabled)
Clear Memory Code + 1

Reset Smoke 4-digit code + 1 (OFF) twice to turn off siren and reset smoke
(If this does NOT reset smoke detector set for service, smoke is bad)
Arm Multiple
Partitions
4-Digit Code + 0 + Arm/Disarm command
(2 for away in all partitions, 3 for stay in all partitions, 1 to disarm all partitions, etc.)
(Code must have authority in all partitions to work. ie, Master Code)
Activate Relay 4-digit Code + # + 7+ Output no#
Deactivate Relay 4-digit Code + # + 8 + Output no#
Move Partition 4-Digit Code + * + partition number
(code mut have authority in the partition you are trying to move to)
Pager Reports Alarms Account + 1911 + 3 digit Zone #
Openings Account + 1001 + 3 digit User #
Closings Account + 1002 + 3 digit User #
Trouble Account + 1811 + 3 digit Zone #
Note: The date and time can be updated without an Alpha just follow the steps. Ensure that the panel is disarmed.
Date and Time To program without an Alpha Keypad
Installer or Master code + # + 6 + 3 + *
Enter the 2 digit hour
Enter the 2 digit minute
Press 1 for PM or Press 2 for AM
Enter the 2 digit year
Enter the 2 digit month
Enter the 2 digit day
Press * to exit (# to backup if incorrect entry made)
Must have alpha keypad and panel must be in normal operating mode for the following commands:
Event History Installer or Master code + # 6 + 0
Press * to move forward
Press # to move backwards
Press 0 to exit
Date and Time To program with an Alpha Keypad
Installer or Master code + # + 6 + 3
System will display current time
* to enter the correct time
Enter the 2 digit hour
Enter the 2 digit minute
Press 1 for PM or Press 2 for AM
Enter the 2 digit year
Enter the 2 digit month
Enter the 2 digit day
Press * to exit (# to backup if incorrect entry made)
Schedules Installer or Master code + # + 6 + 4 (See schedules for more information)