This is a Vista-20 without partitioning
Enter Program 4112 + 8 + 0 + 0 (Display should show 20)
or Power down then back up and press * and # within 1 minute
(If exiting programming you can re-enter within 1 minute by pressing * and #)
Move to Location * + Location
View Location # + Location (Display will read off one digit at a time)
Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00

*20 Installer Code I_4_I_1_I_1_I_2_I
*22 RF System Type I_0_I 0 = None
1 = 5800 Receiver

*23 Forced Bypass Enable I_0_I 0 = No
1 = Yes

*24 RF House Code I_0_I_0_I 00 = Disabled, 01 to 31
(for 5804BD and 5827BD Keypad/Keyfobs)

*25 Wired Expansion Module I_0_I 0 = None
1 = 4219 8-Zone Expander
2 = 4229 Zone Expander Module
3 = 4204 Relay Module

*26 Chime by Zone I_0_I 0 = No
1 = Yes

*27 X-10 House Code I_0_I
0 = A 1 = B 2 = C 3 = D 4 = E 5 = F
6 = G 7 = H 8 = I 9 = J #10 = K #11 = L
#12 = M #13 = N #14 = O #15 = P
*28 4285 Voice Module Access Code I_0_I_0_I 00 = Disabled
(Allows access to Voice module) 1st digit = 1 to 9
2nd digit = # + 11 for * or # + 12 for #

*29 Output to Long Range Radio I_0_I 0 = No
1 = Yes

*30 Keyswitch Enable Zone 7 I_0_I 0 = No
1 = Yes

*31 Single Alarm Sounding/Zone I_0_I 0 = No
1 = Yes

*32 Fire Sounder Timeout I_0_I 0 = Timeout
1 = No Timeout

*33 Alarm Bell Timeout I_1_I 0 = None
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
4 = 16 minutes

*34 Exit Delay I_6_I_0_I 00 to 99 seconds

*35 Entry Delay 1 I_3_I_0_I 00 to 99 seconds

*36 Entry Delay 2 I_3_I_0_I 00 to 99 seconds

*37 Audible Exit Warning I_1_I 0 = No
1 = Yes

*38 Confirm Arming Ding I_0_I_0_I 0 = No
1 = Yes

*39 Power Up in Previous State I_0_I 0 = No
1 = Yes

*40 PABX Access Code I_ _I_ _I_ _I_ _I (If 9 is needed to dial add here)
*41 Primary Phone (12 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause
*42 Secondary Phone I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*43 Primary Account Number I_ _I_ _I_ _I_ _I (Last 4 of Account)
(Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15)
*44 Secondary Account Number I_ _I_ _I_ _I_ _I (Do not Program)

*47 Phone System Select I_3_I 0 = Pulse
1 = DTMF (No Watts Line)
2 = Pulse
3 = DTMF (Watts Line)

*48 Report Format I_7_I Primary
I_7_I Secondary
0 = 3/1, 4/1 Ademco L/S Standard
1 = 3/1, 4/1 Radionics Standard
2 = 4/2 Ademco L/S Standard
3 = 4/2 Radionics Standard
6 = 4/2 Ademco Express
7 = Contact ID
8 = 3/1, 4/1 Ademco L/S Expanded
9 = 3/1, 4/1 Radionics Expanded

*49 Split/Dual Reporting I_0_I
To Primary Phone To Secondary Phone
0 = All Reports Backup Only
1 = Alarms, Restore, Cancel All Other Reports
2 = All Reports except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All Reports
4 = All Reports except Open/Close, Test All Reports
5 = All Reports (Dual Reporting) All Reports
6 = All reports except Open/Close Alarms, Open/Close, Troubles
7 = All reports Alarms, Troubles
8 = All reports Alarms, Open/Close, Troubles
9 = All reports except Open/Close Alarms, Open/Close for Users 5-25, Troubles
*50 15 Second Dial Delay I_0_I 0 = No
1 = Yes

*51 Periodic Test Message I_3_I 0 = None
1 = 24 Hours
2 = Weekly
3 = Monthly

*52 Test Report Offset I_1_I 0 = Disabled
1 = 6 Hours
2 = 12 Hours
3 = 18 Hours

*53 Sescoa/Radionics Select I_0_I 0 = Radionics
1 = Sescoa
0 = All Others

*56 Zone Assignments
Hardwired
4219/4229 Hardwire Expander
Expander Trouble/Tamper
Wireless
Duress
Fire Panic
Medical Panic
Police Panic
Zone 01 to 08 2-Wire Smokes Zone 1 only
Zone 10 to 17 4-Wire Smokes can be 2 to 8
Zone 09
Zone 10 to 39
Zone 92
Zone 95
Zone 96
Zone 99

1. At “Program Tool?” press 0, if it shows “Set to Confirm?” press 1
2. “Enter Zn No.” enter which zone to program (01-87, 88-91, 95, 96, 97, 99) press *
3. Keypad will show summary zones programming, press *
4. “Zone Type?” enter type then * 00 = Zone Disabled/Deleted
01 = Delay Zone
02 = Secondary Delay Zone
03 = Perimeter/Instant
04 = Interior Follower/Motions
05 = Trouble by Day/Alarm by Night
06 = 24 hour Silent/Holdup
07 = 24 hour Police Panic
08 = 24 hour Aux/Medical
09 = Fire
10 = Interior Delay
20 = Arm-Stay (RF only)
21 = Arm-Away (RF only)
22 = Disarm (RF only)
23 = No Alarm Response

5. “Report Code?” enter 10 then *
6. “Input Device?” enter device then * 1 = Hardwired
2 = Auxiliary Wired (with 4219/4229 Expander)
3 = Supervised RF (most sensors are RF)
4 = Un-Supervised RF
5 = RF Button Type (Keyfobs/Panics etc)

7. Cursor should flash above the loop number “LP#”, Enter 1 to 4 depending on sensor
Door Switch – Loop 1 = External Sensor Connector
– Loop 2 = Internal Reed Switch
Glassbreak – Loop 1
Smoke Detectors – Loop 1
Motions – Loop 1
Keyfobs – Loop 1 = Bottom Right Button (Each button counts as 1 zone)
– Loop 2 = Top Right Button
– Loop 3 = Top Left Button
– Loop 4 = Bottom Left Button

8. “Serial Prog?” press 1 and either enter the serial number or trip sensor twice
Note: Serial numbers found on sticker on sensor, if not, learn by tripping sensor
9. “Alpha Program?” press 0 if not programming Alpha descriptions
10. ” Keypad will show either new summary for zone or “Enter zone number”
11. If finished programming enter 00 at “Enter zone no” to return to normal programming

*59 Exit Alarm Report Code I_0_I

*60 Trouble Report Code I_1_I_0_I

*61 Bypass Report Code I_0_I_0_I

*62 AC Loss Report Code I_0_I_0_I

*63 Low Bat Report Code I_1_I_0_I

*64 Test Report Code I_1_I_0_I

*65 Open Report Code I_0_I

*66 Away/Stay Report I_0_I Stay
I_0_I Away

*67 RF Xmtr Low Bat I_0_I_0_I

*68 Cancel Report Code I_1_I_0_I

*70 Alarm Restore Code I_0_I

*71 Trouble Restore Code I_0_I_0_I

*72 Bypass Restore Code I_0_I_0_I

*73 AC Restore Code I_0_I_0_I

*74 Low Bat Rest Code I_0_I_0_I

*75 RF Low Bat Rest Code I_0_I_0_I

*76 Test Restore Rpt Code I_0_I_0_I

*80 Output Relays (Usually program only if 4204 Relay is enabled in *25)

*81 Output Relays (Usually program only if 4204 Relay is enabled in *25)

*82 Custom Alpha Editing (Do not Program)

*83 Sequential Mode (Alternate way of programming sensors, not used)

*88 Pager Characters (24 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*89 Event Log 80% Full I_0_I_0_I
*90 Event Logging I_0_I 0 = None
1 = Alarm/Restore
2 = Trouble/Restore
4 = Bypass/Bypass Restore
8 = Open/Close

*91 Option Selection I_0_I 0 = None
4 = AAV 2-way module enable
(4 turns off siren during 2-way)

Note: Panel MUST be properly grounded for this to work!
*92 Phone Monitor Enable I_0_I 0 = Not Used
1 = KP Display
2 = KP Display/Sounder
3 = KP Display/Sounder/Device 2 starts

*93 Reports per Armed Period I_0_I 0 = 10 per Armed period
1 = Unlimited per Armed period

*94 Download Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

*95 Ring Count I_# 15_I 0 to #15 #15 = Answer Machine Defeat)

*96 Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s)
*97 Default Panel (No Value needed, keypad will beep and default panel)
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0)
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0)