*20 Installer Code | I_4_I_1_I_1_I_2_I | |||||||||||||||||||
*21 Quick Arm Enable | I_1_I Partition 1 I_1_I Partition 2 |
0 = No 1 = Yes |
||||||||||||||||||
*22 RF System Type | I_0_I |
0 = None 1 = 5800 Receiver |
||||||||||||||||||
*23 Forced Bypass Enable | I_0_I Partition 1 I_0_I Partition 2 |
0 = No 1 = Yes |
||||||||||||||||||
*24 RF House Code | I_0_I_0_I |
00 = Disabled 01 to 31 |
||||||||||||||||||
(Partition 2 RF House ID = Partition 1 House ID + 1) | ||||||||||||||||||||
*25 Wired Expansion Module | I_0_I |
0 = None 1 = 4219 8-Zone Expander 2 = 4229 Zone Expander Module 3 = 4204 Relay Module |
||||||||||||||||||
*26 Chime by Zone | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||
*27 X-10 House Code | I_0_I |
|
||||||||||||||||||
*28 4285 Voice Module Access Code | I_0_I_0_I |
00 = Disabled 1st digit = 1 to 9 2nd digit = # + 11 for * or # + 12 for # |
||||||||||||||||||
(Allows access to Voice module)
|
||||||||||||||||||||
*29 Output to Long Range Radio | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||
*30 Keyswitch Enable Zone 7 | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||
*32 Single Alarm Sounding/Zone | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||
*33 Fire Sounder Timeout | I_1_I |
0 = Timeout 1 = No Timeout |
||||||||||||||||||
*34 Alarm Bell Timeout | I_2_I |
0 = None 1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
||||||||||||||||||
*35 Entry Delay | I_2_I Partition 1 I_2_I Partition 2 |
0 = No Delay 1 = 20 seconds 2 = 30 seconds 3 = 45 seconds 4 = 60 seconds 5 = 90 seconds |
||||||||||||||||||
(Exit Delay = Entry Delay + 40 Seconds) | ||||||||||||||||||||
*36 Audible Exit Warning | I_1_I Partition 2 I_1_I Partition 2 |
0 = No 1 = Yes |
||||||||||||||||||
*37 Confirmation of Arming Ding | I_1_I Partition 2 I_1_I Partition 2 |
0 = No 1 = Yes |
||||||||||||||||||
*38 Power Up in Previous State | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||
*40 PABX Access Code | I_ _I_ _I_ _I_ _I (If 9 is needed to dial add here) | |||||||||||||||||||
*41 Primary Phone (12 digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = *# + 12 = # # + 13 = 2.5 second pause |
|||||||||||||||||||
*42 Secondary Phone |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (The original Vista-20 cannot do Pagers, only Vista-20SE’s can) |
|||||||||||||||||||
*43 Primary Account Partition 1 |
I_ _I_ _I_ _I_ _I (Last 4 of Account) A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 |
|||||||||||||||||||
*44 Secondary Account Partition 1 | I_ _I_ _I_ _I_ _I | |||||||||||||||||||
*45 Primary Account Partition 2 | I_ _I_ _I_ _I_ _I | |||||||||||||||||||
*46 Secondary Account Partition 2 | I_ _I_ _I_ _I_ _I | |||||||||||||||||||
*47 Phone System Select | I_3_I |
0 = Pulse Dial 1 = DTMF Dial 2 = Pulse Dial, CS on Watts Line 3 = DTMF Dial, CS on Watts Line |
||||||||||||||||||
*48 Report Format | I_7_I Partition 1 I_7_I Partition 2 |
0 = 3/1, 4/1 Ademco L/S Standard 1 = 3/1, 4/1 Radionics Standard 2 = 4/2 Ademco L/S Standard 3 = 4/2 Radionics Standard 6 = 4/2 Ademco Express 7 = Contact ID 8 = 3/1, 4/1 Ademco L/S Expanded 9 = 3/1, 4/1 Radionics Expanded |
||||||||||||||||||
*49 Split/Dual Reporting | I_0_I | |||||||||||||||||||
|
||||||||||||||||||||
*50 15 sec Dial Delay | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||
*51 Periodic Test Message | I_0_I |
0 = None 1 = 24 Hours 2 = Weekly 3 = Monthly |
||||||||||||||||||
*52 Test Report Offset | I_0_I |
0 = Disabled 1 = 6 Hours 2 = 12 Hours 3 = 18 Hours |
||||||||||||||||||
*53 Sescoa/Radionics | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||
*56 Zone Assignments | ||||||||||||||||||||
Hardwired 4219/4229 Hardwire Expander Expander Trouble/Tamper Wireless Duress Fire Panic Medical Panic Police Panic |
Zone 01 to 08 (2-Wire Smokes Zone 1 only, 4-Wire can be 2 to 8) Zone 10 to 17 Zone 09 Zone 10 to 63 (Depending on capacity of 5881 receiver) Zone 92 Zone 95 Zone 96 Zone 99 |
|||||||||||||||||||
1. Keypad displays “Zone Prog?” press 1 | ||||||||||||||||||||
2. “Enter Zn No.” enter which zone to program (01-87, 88-91, 95, 96, 97, 99) press * | ||||||||||||||||||||
3. Keypad will show summary zones programming, press * | ||||||||||||||||||||
4. “Zone Type?” enter type then * |
00 = Zone Disabled/Deleted 01 = Delay Zone 02 = Secondary Delay Zone 03 = Perimeter/Instant 04 = Interior Follower/Motions 05 = Trouble by Day/Alarm by Night 06 = 24 hour Silent/Holdup 07 = 24 hour Police Panic 08 = 24 hour Aux/Medical 09 = Fire 10 = Interior Delay 20 = Arm-Stay (RF only) 21 = Arm-Away (RF only) 22 = Disarm (RF only) 23 = No Alarm Response 24 = Silent Burglary |
|||||||||||||||||||
5. “Partition?” Enter 1 or 2 then press * | ||||||||||||||||||||
6. “Report Code?” enter 10 then * | ||||||||||||||||||||
7. “Input Device?” enter device then * |
1 = for Hardwired 2 = Auxiliary Wired (with 4219/4229 Expander) 3 = for Supervised RF (most sensors are RF) 4 = for Un-Supervised RF 5 = RF Button Type (Keyfobs/Panics etc) |
|||||||||||||||||||
8. Cursor should flash above the loop number “LP#”, Enter 1 to 4 depending on sensor | ||||||||||||||||||||
Door Switch |
– Loop 1 = External Sensor Connector – Loop 2 = Internal Reed Switch |
|||||||||||||||||||
Glassbreak | – Loop 1 | |||||||||||||||||||
Smoke Detectors | – Loop 1 | |||||||||||||||||||
Motions – Loop 1 | ||||||||||||||||||||
Keyfobs |
– Loop 1 = Bottom Right Button (Each button counts as 1 zone) – Loop 2 = Top Right Button – Loop 3 = Top Left Button – Loop 4 = Bottom Left Button |
|||||||||||||||||||
9. “Learn Sensor Y/N?” press 1 and trip sensor twice (you cannot enter serial numbers) | ||||||||||||||||||||
10. “Alpha Program?” press 0 if not programming Alpha descriptions | ||||||||||||||||||||
11. ” Keypad will show either new summary for zone or “Enter zone number” | ||||||||||||||||||||
12. If finished programming enter 00 at “Enter zone no” to return to normal programming | ||||||||||||||||||||
*59 Exit Alarm Report Code | I_0_I | |||||||||||||||||||
*60 Trouble Report Code | I_1_I_0_I | |||||||||||||||||||
*61 Bypass Report Code | I_0_I_0_I | |||||||||||||||||||
*62 AC Loss Report Code | I_1_I_0_I | |||||||||||||||||||
*63 Low Bat Report Code | I_1_I_0_I | |||||||||||||||||||
*64 Test Report Code | I_0_I_0_I | |||||||||||||||||||
*65 Open Report Code |
I_0_I Partition 1 I_0_I Partition 2 |
|||||||||||||||||||
*66 Away/Stay Report |
I_0_I_0_I Partition 1 I_0_I_0_I Partition 2 |
|||||||||||||||||||
*67 RF Xmtr Low Bat | I_0_I_0_I | |||||||||||||||||||
*68 Cancel Report Code | I_1_I_0_I | |||||||||||||||||||
*70 Alarm Restore Code | I_0_I | |||||||||||||||||||
*71 Trouble Restore Code | I_0_I_0_I | |||||||||||||||||||
*72 Bypass Restore Code | I_0_I_0_I | |||||||||||||||||||
*73 AC Restore Code | I_0_I_0_I | |||||||||||||||||||
*74 Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||||
*75 RF Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||||
*76 Test Restore Rpt Code | I_0_I_0_I | |||||||||||||||||||
*80 Output Relays | (Usually program only if 4204 Relay is enabled in *25) | |||||||||||||||||||
*81 Output Relays | (Usually program only if 4204 Relay is enabled in *25) | |||||||||||||||||||
*82 Custom Alpha Editing | (Do not Program) | |||||||||||||||||||
*83 Sequential Mode | (Alternate way of programming sensors, not used) | |||||||||||||||||||
*89 Event Log 80% Full | I_0_I_0_I | |||||||||||||||||||
*90 Event Logging | I_0_I |
0 = None 1 = Alarm/Restore 2 = Trouble/Restore 4 = Bypass/Bypass Restore 8 = Open/Close |
||||||||||||||||||
*91 Option Selection I_0_I |
0 = None 4 = AAV |
|||||||||||||||||||
(Panel MUST be properly grounded for this to work!) | ||||||||||||||||||||
*92 Phone Monitor Enable | I_0_I |
0 = Not Used 1 = KP Disp 2 = KP Disp/Sounder 3 = KP Disp/Sounder/Dev 2 starts |
||||||||||||||||||
*93 Reports per Armed Period | I_0_I |
0 = 10 per Armed period 1 = Unlimited per Armed period |
||||||||||||||||||
*94 Download Phone Number | I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I_ _I | |||||||||||||||||||
*95 Ring Count | I_# 15_I | 0 to #15 #15 = Answer Machine Defeat | ||||||||||||||||||
*96 Reinitialize Download | ||||||||||||||||||||
*97 Default Panel | (No Value needed, keypad will beep and default panel) | |||||||||||||||||||
*98 Exits Program Mode | (Will not allow re-entry with Installer Code + 8 + 0 + 0) | |||||||||||||||||||
*99 Exits Program Mode | (Will allow re-entry with Code + 8 + 0 + 0) |