Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 20)
or Power down then back up and press * and # within 1 minute
(If exiting programming you can re-enter within 1 minute by pressing * and #)
Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00
Move to Location * + Location
View Location # + Location (Display will read off one digit at a time)

*20 Installer Code I_4_I_1_I_1_I_2_I
*21 Quick Arm Enable I_1_I 0 = No
1 = Yes

*22 RF System Type I_0_I 0 = None
1 = 5800 Receiver

*23 Forced Bypass Enable I_0_I 0 = No
1 = Yes

*24 RF House Code I_0_I_0_I 00 = Disabled, 01 to 31
(Partition 2 House Code = Partition 1 House ID + 1)

*25 Wired Expansion Module I_0_I 0 = None
1 = 4219 8-Zone Expander
2 = 4229 Zone Expander Module
3 = 4204 Relay Module

*26 Chime by Zone I_0_I 0 = No
1 = Yes

*27 X-10 House Code I_0_I
0 = A 1 = B 2 = C 3 = D 4 = E 5 = F
6 = G 7 = H 8 = I 9 = J #10 = K #11 = L
#12 = M #13 = N #14 = O #15 = P
*28 4285 Voice Module Access Code I_0_I_0_I 00 = Disabled
1st digit = 1 to 9
2nd digit = # + 11 = * or # + 12 = #

*29 Output to Long Range Radio I_0_I 0 = No
1 = Yes

*30 Hardwire Short Detection I_0_I 0 = Disable
1 = Enable

*31 Single Alarm Sounding/Zone I_0_I 0 = No
1 = Yes

*32 Fire Sounder Timeout I_0_I 0 = Timeout
1 = No Timeout

*33 Alarm Bell Timeout I_1_I 0 = None
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
4 = 16 minutes

*34 Exit Delay I_6_I_0_I 0 = 30 seconds
1 = 45 seconds
2 = 60 seconds
3 = 90 seconds
4 = 120 seconds
5 = 180 seconds
6 = 240 seconds

*35 Entry Delay 1 I_3_I_0_I
*36 Entry Delay 2 I_4_I_5_I
*37 Audible Exit Warning I_1_I 0 = No
1 = Yes

*38 Confirm Arming Ding I_0_I 0 = No
1 = Yes
2 = Yes RF Only

*39 Power Up in Previous State I_0_I 0 = No
1 = Yes

*40 PABX Access Code (6 digits) I_ _I_ _I_ _I_ _I_ _I_ _I (If 9 is needed to dial add here)
*41 Primary Phone (20 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause
*42 Secondary Phone (20 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*43 Primary Account I_ _I_ _I_ _I_ _I (Last 4 of Account)
(Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15
*44 Secondary Account I_ _I_ _I_ _I_ _I (Do not Program)

*45 Phone System Select I_1_I 0 = Pulse Dial
1 = DTMF Dial
2 = Pulse Dial, CS on Watts Line
3 = DTMF Dial, CS on Watts Line

*46 Report Format I_7_I Primary
I_7_I Secondary
0 = 3/1, 4/1 Ademco L/S Standard
1 = 3/1, 4/1 Radionics Standard
2 = 4/2 Ademco L/S Standard
3 = 4/2 Radionics Standard
6 = 4/2 Ademco Express
7 = Contact ID
8 = 3/1, 4/1 Ademco L/S Expanded
9 = 3/1, 4/1 Radionics Expanded

*47 Split/Dual Reporting I_0_I
To Primary Phone To Secondary Phone
0 = All Reports Backup Only
1 = Alarms, Restore, Cancel All Other Reports
2 = All Reports except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All Reports
4 = All Reports except Open/Close, Test All Reports
5 = All Reports (Dual Reporting) All Reports
6 = All reports except Open/Close Alarms, Open/Close, Troubles
7 = All reports Alarms, Troubles
8 = All reports Alarms, Open/Close, Troubles
9 = All reports except Open/Close Alarms, Open/Close for Users 5-25, Troubles
*48 Dial Delay I_0_I 0 = No Delay
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
4 = 60 seconds
5 = 120 seconds

*49 Periodic Test Message I_3_I 0 = None
1 = 24 Hours
2 = Weekly
3 = Monthly

*50 Test Report Offset I_1_I 0 = Disabled
1 = 6 Hours
2 = 12 Hours
3 = 18 Hours

*51 Sescoa/Radionics I_0_I 0 = Radionics
1 = Sescoa
0 = All Others

*52 Cancel Verify I_1_I 0 = No
1 = Yes

Must use 6139 Alpha Keypad here
*56 Zone Assignments (Max 26 hardwired and/or wireless zones in addition to the 6 onboard zones)
Hardwired
Expander Trouble/Tamper
Wireless
Duress
Fire Panic
Medical Panic
Police Panic
Zone 01 to 06 (2-Wire Smokes Zone 1 only, 4-Wire can be 2 to 6)
Zone 09
Zone 10 to 35 (Depending on capacity of 5881 receiver)
Zone 92
Zone 95
Zone 96
Zone 99
1. At “Set to Confirm?” press 1 (1 = confirm serial number by activating sensor, 0 = just learn serial)
2. “Enter Zn No.” enter which zone to program (01-87, 88-91, 95, 96, 97, 99) press *
3. Keypad will show summary zones programming, press *
4. “Zone Type?” enter type then * 00 = Zone Disabled/Deleted
01 = Delay Zone
02 = Secondary Delay Zone
03 = Perimeter/Instant
04 = Interior Follower/Motions
05 = Trouble by Day/Alarm by Night
06 = 24 hour Silent/Holdup
07 = 24 hour Police Panic
08 = 24 hour Aux/Medical
09 = Fire
10 = Interior Delay
20 = Arm-Stay (RF only)
21 = Arm-Away (RF only)
22 = Disarm (RF only)
23 = No Alarm Response
5. “Response Time?” Enter 1 then * 0 = 10msec
1 = 350msec
2 = 700msec
6. “Report Code?” enter 10 then *
7. “Input Device?” enter device then * 1 for Hardwired
2 for Auxiliary Wired (with 4219/4229 Expander)
3 for Supervised RF (most sensors are RF)
4 for Un-Supervised RF
5 RF Button Type (Keyfobs/Panics etc)
8. Cursor should flash above the loop number “LP#”, Enter 1 to 4 depending on sensor then *
Door Switch – Loop 1 = External Sensor Connector
– Loop 2 = Internal Reed Switch
Glassbreak – Loop 1
Smoke Detectors – Loop 1
Motions – Loop 1
Keyfobs – Loop 1 = Bottom Right Button (Each button counts as 1 zone)
– Loop 2 = Top Right Button
– Loop 3 = Top Left Button
– Loop 4 = Bottom Left Button
9. “Serial Prog?” press 1 and either enter the serial number or trip sensor twice
Note: Serial numbers found on sticker on sensor, if not, learn by tripping sensor
10. “Alpha Program?” press 0 if not programming Alpha descriptions
11. ” Keypad will show either new summary for zone or “Enter zone number”
12. If finished programming enter 00 at “Enter zone no” to return to normal programming

*59 Exit Alarm Report Code I_0_I

*60 Trouble Report Code I_1_I_0_I

*61 Bypass Report Code I_0_I_0_I

*62 AC Loss Report Code I_0_I_0_I

*63 Low Bat Report Code I_1_I_0_I

*64 Test Report Code I_1_I_0_I

*65 Open Report Code I_0_I

*66 Away/Stay Report I_0_I_0_I

*67 RF Xmtr Low Bat I_0_I_0_I

*68 Cancel Report Code I_1_I_0_I

*70 Alarm Restore Code I_0_I

*71 Trouble Restore Code I_0_I_0_I

*72 Bypass Restore Code I_0_I_0_I

*73 AC Restore Code I_0_I_0_I

*74 Low Bat Rest Code I_0_I_0_I

*75 RF Low Bat Rest Code I_0_I_0_I

*76 Test Restore Rpt Code I_0_I_0_I

*77 Daylight Savings
     Start/End Month
I_4_I_10_I 0 = Disabled
1 = January to 12 = December
*78 Daylight Savings
     Start/End Weekend
I_1_I Start
I_5_I End
1 = 1st Weekend
2 = 2nd Weekend
3 = 3rd Weekend
4 = 4th Weekend
5 = Last Weekend
6 = Next to Last Weekend
7 = 3rd from Last Weekend

*79 Dynamic Signaling I_0_I DS Delay
I_0_I DS Priority
0 = No Delay, 1 to 15×15 seconds
0 = Primary Phone First, 1 = LRR first

*80 Output Relays (Usually program only if 4204 Relay is enabled in *25)
*81 Output Relays (Usually program only if 4204 Relay is enabled in *25)
*82 Custom Alpha Editing (Do not Program)

*84 Auto Stay Arming I_0_I 0 = No
1 = Yes

*85 Cross Zone Timer I_0_I 0 = 30 seconds
1 = 45 seconds
2 = 60 seconds
3 = 90 seconds
4 = 120 seconds
5 = 180 seconds
6 = 240 seconds

*87 Alarm Pager Delay Time I_3_I 0 = None
1 = 1 minutes
2 = 2 minutes
3 = 3 minutes

*88 Pager Characteristics (16 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*89 Event Log 80% Full Reporting I_0_I_0_I

*90 Event Logging I_0_I 0 = None
1 = Alarm/Restore
2 = Trouble/Restore
4 = Bypass/Bypass Restore
8 = Open/Close

*91 Option Selection I_0_I 0 = None
4 = AAV 2-way module enabled
8 = Enable Exit Delay Restart
12 = Exit Delay Restart & AAV Enable

(Panel MUST be properly grounded for this to work!)
*92 Phone Monitor Enable I_0_I 0 = Not Used
1 = KP Display
2 = KP Display/Sounder
3 = KP Display/Sounder/Dev #2 starts

*93 Swinger Suppression I_3_I 0 = Unlimited
1 to 15 = 1 to 15 Alarms while Armed

*94 Download Phone (20 digits) I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I_ _I
*95 Ring Count I_# 15_I 0 to #15 #15 = Answer Machine Defeat
*96 Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s)
*97 Default Panel (No Value needed, keypad will beep and default panel)
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0)
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0)