Ademco Vista 128 Program
Enter Program |
5140 + 8 + 0 + 0 + 0 (Display should show 00) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) |
|||
Exit Program | *98 OR *99 if needing to re-enter programming later by Code + 8 + 00 | |||
Move to Location | * + Location | |||
View Location | # + Location (Display will read off one digit at a time) | |||
Timer Test |
*26 I_0_I *27 I_7_I_4_I_4_I Monthly *83 I_0_I_0_I_1_I_2_I_0_I_0_I #93 Scroll to”REPORT CODE PRG” select SYSTEM GROUP #1 scroll until you see TEST and enter I_1_I_1_I |
|||
Cell Primary |
*32 Enter Account No# *33 blank *56 I_0_I_0_I *57 I_1_I *58 I_1_I_1_I_1_I_1_I_1_I_1_I #93 Menu, Hit 0 until Device address programming; 1 for yes. Choose radio’s address, and in device type enter 6 for LRR. |
|||
Secure Cell |
*32 Enter Account No# *33 Enter Reciever No# *56 I_0_I_I_2_I *57 I_0_I *58 I_1_I_1_I_1_I_1_I_1_I_1_I #93 Menu, Hit 0 until Device address programming; 1 for yes. Choose radio’s address, and in device type enter 6 for LRR. |
|||
|
||||
E-SECURE | All Zone programming is done by # 93 menu, Click to go to section | |||
ZONE PROG? | 0 (No) for next menu, 1 (Yes) to enter this menu (Completed) | |||
EXPERT MODE? | 0 (No) for next menu, 1 (Yes) to enter this menu (Completed) | |||
REPORT CODE PRG? | 0 (No) for next menu, 1 (Yes) to enter this menu (Completed) | |||
ALPHA PROG? | 0 (No) for next menu, 1 (Yes) to enter this menu (Under Construction) | |||
DEVICE PROGR? | 0 (No) for next menu, 1 (Yes) to enter this menu (Under Construction) | |||
OUTPUT PROG? | 0 (No) for next menu, 1 (Yes) to enter this menu (Under Construction) | |||
RLY VOICE DESCR? | 0 (No) for next menu, 1 (Yes) to enter this menu (Under Construction) | |||
CUSTOM INDEX? | 0 (No) moves back to start, 1 (Yes) to enter this menu (Under Construction) | |||
|
||||
*00 Installer Code | I_5_I_1_I_4_I_0_I | |||
*08 Temporal Siren Pulse | I_0_I |
0 = No 1 = Yes |
||
*09 Entry Delay | I_0_I_2_I | 00 to 15 x15 seconds (Partition-Specific) | ||
*10 Exit Delay 1 | I_0_I_4_I | 00 to 15 x15 seconds (Partition-Specific) | ||
*11 Entry Delay 2 | I_0_I_3_I | 00 to 15 x15 seconds (Partition-Specific) | ||
*12 Exit Delay 2 | I_0_I_4_I | 00 to 15 x15 seconds (Partition-Specific) | ||
*13 Bell 1 Timeout | I_0_I_8_I | 00 to 15 x2 minutes (Partition-Specific) | ||
*15 Keyswitch Assignment | I_0_I |
0 = Keyswitch Disabled 1 = Partition 1 to 8 = Partition 8 9 = Silence Bell if Fire Present |
||
*16 Bell 1 Confirm Arming Ding | I_0_I |
0 = Disable (Partition-Specific) 1 = Enable |
||
*17 AC Loss Keypad Sounding | I_1_I |
0 = No 1 = Yes |
||
*19 AC Randomize | I_2_I |
0 = No 1 = Randomize 10 – 40 minutes 2 = Randomize 6 – 12 Hours |
||
*20 VIP Module Phone Code | I_0_I_0_I I_1_I_1_I |
1st Digit = 01 to 09 2nd Digit = 11 for * 12 for # |
||
*22 Keypad Panic Enable | I_1_I I_1_I I_1_I |
0 = Disabled (Partition-Specific) 1st Digit = Zone 995 1 = Enabled 2nd Digit = Zone 996 3rd Digit = Zone 999 |
||
*23 Multiple Alarms | I_1_I |
0 = No (Partition-Specific) 1 = Yes |
||
*24 Ignore Exp Zone Tamper | I_0_I |
0 = Enable Tamper for RF & RPM 1 = Ignore Zone Tampers |
||
*25 LRR Burg Trigr for ZType 8 | I_0_I |
0 = No 1 = Yes |
||
*26 Intelligent Test Reprting | I_0_I |
0 = No 1 = No Report if other Reports Sent |
||
*27 Test Report Interval | I_0_I_2_I_4_I |
000 = Disabled 001 to 999 Hours |
||
*28 Power up in Prev State | I_1_I |
0 = No 1 = Yes |
||
*29 Quick Arm | I_1_I |
0 = No (Partition-Specific) 1 = Yes |
||
*30 Main Dialer Tone Dialing | I_1_I |
0 = No 1 = Yes |
||
*31 PABX Access Code | I_ _I_ _I I_ _I_ _I I_ _I_ _I I_ _I_ _I | |||
*32 Primary Account Number |
I_0_I_?_I I_0_I_?_I I_0_I_?_I I_0_I_?_I (2 digit entries) (Partition-Specific) Hex B = 11, C = 12, D = 13, E = 14, F = 15 |
|||
*33 Primary Phone Number |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = *, # + 12 = #, # + 13 = 2.5 second pause |
|||
*34 Secondary Phone Number | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I | |||
*35 Download Phone Number | I_1_I_8_I_6_I_6_I_6_I_7_I_8_I_3_I_8_I_0_I_2_I_ _I_ _I_ _I_ _I | |||
*36 CSID Number |
I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I (15’s Default CSID to Factory) |
|||
*37 Download Commands Enable |
I_1_I Dialer Shutdown I_1_I System Shutdown I_0_I Not Used I_1_I Remote Bypass I_1_I Remote Disarm I_1_I Remote Arm I_1_I Upload Prgramming I_1_I Dwnload Prgramming |
0 = No 1 = Yes |
||
*38 Prevent Zone Bypass | I_0_I_0_I_0_I |
000 = All zones bypassable (Partition-Specific) 001 to 128 = Zone 1 to 128 |
||
*39 O/C Report for Installer | I_0_I |
0 = No (Partition-Specific) 1 = Yes |
||
*40 O/C Report for Keyswitch | I_0_I |
0 = No 1 = Yes |
||
*41 Normally Clsd Zns 3 to 8 | I_0_I |
0 = EOL Resistors 1 = Normally Closed |
||
*42 Dial Tone Pause | I_0_I |
0 = 5 seconds 1 = 11 seconds 2 = 30 seconds |
||
*43 Dial Tone Detection | I_0_I |
0 = Pause then Dial 1 = Wait for True Dial Tone |
||
*44 Ring Detection Count | I_1_I_5_I | 15 = Answering Machine | ||
*45 Primary Format | I_1_I |
0 = Ademco Lo 1 = Contact ID 2 = Ademco High Speed 3 = Ademco Express |
||
*46 Low Speed Format (Prime) | I_0_I |
0 = Ademco Low Speed 1 = Sescoa/Radionics |
||
*47 Secondary Format | I_1_I |
0 = Ademco Lo 1 = Contact ID 2 = Ademco High Speed 3 = Ademco Express |
||
*48 Low Speed Format (Second) | I_0_I |
0 = Ademco Low Speed 1 = Sescoa/Radionics |
||
*49 Checksum Verify | I_0_I_0_I |
0 = No Pri Sec 1 = Yes |
||
*50 Sescoa Radionics Select | I_0_I |
0 = Radionics 1 = Sescoa |
||
*51 Dual Reporting | I_0_I |
0 = No 1 = Yes |
||
*52 Stndrd/Exp Report for Primary |
I_0_I Alarm/Fire Supv I_0_I Restore I_0_I Bypass I_0_I Trouble I_0_I Open/Close I_0_I Low Bat/Walk |
0 = Standard 1 = Expanded |
||
*53 Stndrd/Exp Report for Secondary |
I_0_I Alarm/Fire Supv I_0_I Restore I_0_I Bypass I_0_I Trouble I_0_I Open/Close I_0_I Low Bat/Walk Test |
0 = Standard 1 = Expanded |
||
*56 Dynamic signaling delay | I_0_I_2_I | 00 to 15 x15 seconds | ||
*57 Dynamic signaling priority | I_0_I |
0 = Telephone First 1 = Long Range Radio First |
||
*58 LRR Enable CS#1 |
I_0_I Alarm I_0_I Trouble I_0_I Bypass I_0_I Open/Close I_0_I System I_0_I Test |
0 = Disable 1 = Enable |
||
*59 LRR Enable CS#2 |
I_0_I Alarm I_0_I Trouble I_0_I Bypass I_0_I Open/Close I_0_I System I_0_I Test |
0 = Disable 1 = Enable |
||
*64 Pager Installed | I_0_I |
0 = No 1 = Yes |
||
*65 Pager Phn for Alarms |
(17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = *, # + 12 = #, # + 13 = 2.5 second pause |
|||
*66 Pager ID# for Alarms | (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End with * | |||
*67 Pager Phn for Trbl |
(17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = *, # + 12 = #, # + 13 = 2.5 second pause |
|||
*68 Pager ID# for Trbl | (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End with * | |||
*69 Pager Phn for Bypass |
(17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = *, # + 12 = #, # + 13 = 2.5 second pause |
|||
*70 Pager ID# for Bypass | (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End with * | |||
*71 Pager Phn for O/C |
(17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = *, # + 12 = #, # + 13 = 2.5 second pause |
|||
*72 Pager ID# for O/C | (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End with * | |||
*73 Pager Phn for System |
(17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = *, # + 12 = #, # + 13 = 2.5 second pause |
|||
*74 Pager ID# for System | (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End with * | |||
*75 Pager Phn for Test |
(17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = *, # + 12 = #, # + 13 = 2.5 second pause |
|||
*76 Pager ID# for Test | (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End with * | |||
*79 Zone Type Restore Enable Zone Types 1 to 8 I_0_I Zone Type 1 (Entry/Exit 1) I_0_I Zone Type 2 (Entry Exit 2) I_0_I Zone Type 3 (Perimeter) I_0_I Zone Type 4 (Interior Follower) I_0_I Zone Type 5 (Day/Night) I_0_I Zone Type 6 (24 Hour Silent) I_0_I Zone Type 7 (24 Hour Audible) I_0_I Zone Type 8 (24 Hour Auxiliary) |
0 = No Restoral Report 1 = Restoral Report |
|||
*80 Zone Type Restore Enable Zone Types 9 and 10 I_0_I Zone Type 9 (Fire w/o verify) I_0_I Zone Type 10 (Interior w/Delay) |
0 = No Restoral Report 1 = Restoral Report |
|||
*83 First Test Report Time | I_0_I_0_I I_1_I_2_I I_0_I_0_I |
00 ina all boxes = instant. Day Hour Minutes Day 01 = Monday |
||
*84 Swinger Shutdown | I_0_I_4_I |
00 = Disabled (Partition-Specific) 01 to 15 = 01 to 15 Alarms |
||
*85 Enable Dialer Reports |
I_1_I Zone 995 I_1_I Zone 996 I_1_I Zone 999 I_1_I Duress |
0 = Disable (Partition-Specific) 1 = Enable |
||
*87 Entry Warning | I_1_I |
0 = 3 Beeps (Partition-Specific) 1 = Continuous |
||
*88 Burg Alarm Comm Delay | I_0_I |
0 = No Delay (Partition-Specific) 1 = 16 seconds |
||
*89 Restr Report Timing | I_0_I |
0 = Instant 1 = At Bell Timeout 2 = At Disarm |
||
*90 2nd Account # |
I_ _I_ _I I_ _I_ _I I_ _I_ _I I_ _I_ _I (2 digit entries) Hex B = 11, C = 12, D = 13, E = 14, F = 15 |
|||
|
||||
To access Upper programming press *94, to return to lower programming press *99 the 1 isn’t part of location, to go to a Upper program location press * + 2-digits | ||||
|
||||
1*17 Common Lobby Part | I_0_I |
0 = Disabled 1 = Partition 1 to 8 = Partition 8 |
||
1*18 Affects Lobby | I_0_I |
0 = Does Not Affect Lobby (Partition-Specific) 1 = Affects Lobby (Disarms Lobby and keeps from arming) |
||
1*19 Arms Lobby | I_0_I |
0 = Does Not Arm Lobby (Partition-Specific) 1 = Arms Lobby |
||
1*20 Exit Error Logic | I_0_I |
0 = No 1 = Bypass E/E & Interior Zones faulted after Exit Delay |
||
1*21 Exit Delay Reset | I_0_I |
0 = No 1 = Resets Exit Delay to 60 seconds after Zone is Closed |
||
1*22 Cross-Zoning Pair 1 | I_ _I_ _I_ _I I_ _I_ _I_ _I | |||
1*23 Cross-Zoning Pair 2 | I_ _I_ _I_ _I I_ _I_ _I_ _I | |||
1*24 Cross-Zoning Pair 3 | I_ _I_ _I_ _I I_ _I_ _I_ _I | |||
1*25 Cross-Zoning Pair 4 | I_ _I_ _I_ _I I_ _I_ _I_ _I | |||
1*26 Enable Dialer Reports |
I_0_I_0_I 995 Panic Button A I_0_I_0_I 999 Panic Button B I_0_I_0_I 996 Panic Button C I_0_I_0_I Macro Button D |
00 = Used as Panic (Partition-Specific) 01 to 25 = Macro |
||
1*28 RF TX Low Batt Sound | I_0_I |
0 = When Disarmed 1 = Immediate |
||
1*29 RF TX Low Batt Report | I_0_I |
0 = Disable 1 = Enable |
||
1*30 RF RCVR Check-In Interval | I_0_I_2_I | 02 to 15 x2 Hours | ||
1*31 RF xmitter Check-In Interval | I_0_I_2_I | 02 to 15 x2 Hours | ||
1*33 Tone with Rotory Backup | I_1_I |
0 = Disable 1 = Enable |
||
1*34 Comm Split Report Selection | I_0_I |
0 = No 1 = Alarms to Primary, others Sec. 2 = O/C/Test Secondary, others Pri. 3 = Fire alarms/troubles Primary, all Sec. |
||
1*35 Access Dialer Enables |
I_0_I Trace I_0_I Trouble I_0_I Bypass I_0_I System I_0_I Alarm |
0 = Disable 1 = Enable |
||
1*42 Call Waiting Defeat | I_0_I |
0 = No 1 = Yes |
||
1*43 Perm Keypad Backlight | I_1_I |
0 = No (Partition-Specific) 1 = Yes |
||
1*44 Wireless Keypad Tamper | I_0_I |
0 = Disable 1 = Lockout RF if tamper detected |
||
1*45 – Exit Delay Sounder | I_0_I |
1 = Enable (Partition-Specific) 0 = Disable |
||
1*47 Chime on Bell 1 | I_0_I |
0 = Disable (Partition-Specific) 1 = Enable |
||
1*48 Wireless Keypad Assign | I_0_I |
0 = Disable 1 = Partition 1 to 8 = Partition 8 |
||
1*49 Suppress TX Superv Sound | I_1_I |
0 = Enable 1 = Disable |
||
1*52 Send Canx Alarm + Off | I_0_I |
0 = No Restriction (Partition-Specific) 1 = Within Bell Timeout |
||
1*53 Download Callback | I_1_I |
0 = Callback Required 1 = No Callback |
||
1*56 50/60 Hz Clock Speed | I_0_I |
0 = 60 Hz 1 = 50 Hz |
||
1*57 Enable 5800RF Global Arm | I_0_I |
0 = Disable 1 = Enable |
||
1*58 Enable 5800RF Force Arm | I_0_I |
0 = Disable 1 = Enable |
||
1*60 Zn 5 Audio Alarm Verification | I_0_I |
0 = Disable 1 = Enable |
||
1*70 Event Log Types |
I_1_I Alarm I_1_I Check I_1_I Bypass I_1_I O/C I_1_I System |
0 = Disable Logging 1 = Enable Logging |
||
1*71 12/24 Hr Time Stamp Frmt | I_1_I |
0 = 12 Hour 1 = 24 Hour (Military) |
||
1*72 Event Log Prnter On-line | I_0_I |
0 = Disable 1 = Enable |
||
1*73 Printer Baud Rate | I_0_I |
0 = 1200 Baud 1 = 300 Baud |
||
1*74 Relay Timeout XXX Min. | I_0_I_0_I_0_I |
0 to 127 x2 Minutes Enter relay timeout desired for #80 Menu Mode time-driven event relay command numbers “04/09” and #93 Menu Mode Output Programming output command “56.” |
||
1*75 Relay Timeout YYY Sec. | I_0_I_0_I_0_I |
0 to 127 Seconds Enter relay timeout desired for #80 Menu Mode time-driven event relay command numbers “05/10” and #93 Menu Mode Output Programming output command “57.” |
||
1*76 Access Control Relay | I_0_I_0_I |
00 to 96 (Partition-Specific) Relay will be pulsed for 2 seconds whenever code + [0] is pressed. |
||
1*77 Log First Maint. Signal | I_0_I |
0 = Disable 1 = Enable |
||
|
||||
To access Upper programming press *94, to return to lower programming press *99 the 2 isn’t part of location, to go to a Upper program location press * + 2-digits | ||||
|
||||
2*00 Number of Partitions | I_1_I |
1 = 1 Partition to 8 = 8 Partitions |
||
2*01 DST Start/End Month | I_0_I_3_I I_1_I_1_I |
00, 00 = Disable DST Start End 01 – 12 = Month |
||
2*02 DST Start/End Weekend |
|
1 to 7 1 = First 2 = Second 3 = Third 4 = Fourth 5 = Last 6 = Next to Last 7 = Third from Last |
||
2*05 Auto-Arm Delay | I_1_I_5_I |
00 = Instant (Partition-Specific) 01 to 14 x4 Minutes 15 = No Auto-Arm |
||
2*06 Auto-Arm Warning Period | I_1_I_5_I |
00 = Instant (Partition-Specific) 01 to 15 Minutes |
||
2*07 Auto-Disarm Delay | I_1_I_5_I |
00 = Instant (Partition-Specific) 01 to 14 x4 Minutes 15 = No Auto-Disarm | ||
2*08 Force Arm for Auto-Arm | I_0_I |
0 = Disable (Partition-Specific) 1 = Enable |
||
2*09 O/C Reports by Exception | I_0_I |
0 = Disable (Partition-Specific) 1 = Enable |
||
2*10 Allow Disarming Only During | I_0_I |
0 = Disable (Partition-Specific) Arming/Disarming Windows 1 = Enable |
||
2*11 Disarming Outside Window | I_0_I |
0 = Disable (Only used if 2*10 is a 1) if Alarm Occurs 1 = Enable |
||
2*18 Partition Go To | I_0_I |
0 = Disable (Partition-Specific) 1 = Enable |
||
2*19 Use Partition Descriptors | I_0_I |
0 = Disable 1 = Enable |
||
2*20 J2 Triggers for Partition | I_0_I |
0 = Disable (Partition-Specific) 1 = Enable |
||
2*21 Supervision Pulses For LRR Trigger Outputs |
I_0_I Fire I_0_I Burglary I_0_I Silent panic/Duress I_0_I Supervision I_0_I Trouble |
0 = Disable 1 = Enable |
||
2*22 Display Other Partition’s Fire |
I_0_I |
0 = Disable (Partition-Specific) 1 = Enable |
||
2*23 Display Other Partition’s Burglary & Panic Alarms |
I_0_I |
0 = Disable (Partition-Specific) 1 = Enable |
||
2*24 Display Other Partition’s Troubles |
I_0_I |
0 = Disable (Partition-Specific) 1 = Enable |
||
|
||||
To access Upper programming press *94, to return to lower programming press *99 the 3 isn’t part of location, to go to a Upper program location press * + 2-digits | ||||
|
||||
3*00 Check or Trble Display | I_0_I |
0 = Check Displayed 1 = Trouble Displayed |
||
3*01 Check or Trble Display | I_0_I |
0 = Check Displayed 1 = Trouble Displayed |
||
3*12 Zone Type 18 Delay Use | I_0_I |
0 = No Delay Zone 18 1 = Use Delay in 3*16 |
||
3*13 Open & Short Super | I_0_I |
0 = Supv. on short/trouble on open 1 = Supv. on short or open |
||
3*14 Waterflow Silence Option | I_0_I |
0 = Silence on Code + 1 1 = Silence on restoral |
||
3*15 Alarm Bell Sound |
I_0_I Bell 1 I_0_I Bell 2 |
0 = Pulsed 1 = Steady |
||
3*16 Delay for Zn Types 17 & 18 (Waterflow & Fire Supervision) |
I_0_I_0_I | 00 to 15 x2 seconds | ||
3*17 Alt for zn 6 (Tamper) |
I_0_I_0_I |
0 = Disabled 1 = Enabled |
||
3*18 Ext Delay for ZT 17 & 18 | I_0_I |
0 = Use Delay in 3*16 1 = Multiply 3*16 delay by 4 |
||
3*19 AUX in Alt Function | I_0_I |
0 = Pins 5 & 9 function per 3*20 1 = Pins 5 & 9 as printer RXD & DTR |
||
3*20 Trigger Outputs Selection | I_0_I |
0 = Lorra Full Connection 1 = Lorra Limited Connection/Keyswitch 2 = Lorra Fire Connection & 5140LED |
||
3*21 Max # of Dialer Retries | I_8_I | 1 to 8 attempts | ||
3*30 Dialer Selection |
I_1_I Main I_1_I Backup |
0 = Disabled 1 = Enabled |
||
3*31 Backup Dialer | I_0_I |
0 = Rotary 1 = Touch Tone |
||
3*50 Zn Type Rstr Enable For Zone Types 16 to 18 |
I_1_I Zn Type 16 I_1_I Zn Type 17 I_1_I Zn Type 18 16 = Fire w/Verification 17 = Fire Water Flow 18 = Fire Supervisory |
0 = Disabled 1 = Enabled |
||
3*55 Reset Bell 1 After 2nd off | I_0_I |
0 = Disabled 1 = Enabled |
||
3*56 Reset Bell 2 After 2nd off | I_0_I |
0 = Disabled 1 = Enabled |
||
3*57 Bell 2/Aux Relay Confirm Ding |
I_0_I Bell 2 I_0_I Aux |
0 = Disabled (Partition-Specific) 1 = Enabled |
||
3*59 Bell 2/Aux Relay Chime Annunciation (Partition-Specific) |
I_0_I Bell 2 0 = Disabled I_0_I Aux 1 = Enabled |
|||
3*60 Bell 2/Aux Relay Timeout |
I_0_I_0_I Bell 2 I_0_I_0_I Aux |
0 = Disabled (Partition-Specific) 1 = Enabled |
||
3*61 Aux Relay Function | I_0_I |
0 = Trouble/Supervisory 1 = Alarm/Silenced by Code + OFF 2 = Smoke Detector Reset 3 = Battery Save 4 = Alarm, Silenced by Code + # + 67 |
||
3*82 Burg Features on Par 1 (Away, Stay, Max, Instant, Chime) |
I_1_I |
0 = Disable 1 = Enable |
||
3*85 Enable Fire & Systm Zn Bypass (For Zn Types 9, 16, 17, 18 & 70 to 77) |
I_1_I |
0 = Not Enabled 1 = Only Installer can Bypass 2 = Only Installer & Master can Bypass |