bF | Long Range Radio failure (Cell backup) |
Check 91 | Generic trouble display |
Check 100 | Wireless Receiver failure or keypad tamper |
Check 103 | Long Range Radio failure (Cell backup) |
Check 104 | 4285 or 4286 Voice Module failure |
Check 112 | 4204 Relay Module failure (Module 1) |
NO AC | AC Power Failure |
BAT | Panel Battery Low |
BAT xxx | Wireless zone low battery (where xxx is the zone number) |
Check 01 to 34 | Zone is not communicating with panel |
Check 49 to 56 | Keyfobs are programmed incorrectly |
D1 | System is in wait mode, system may have an internal problem |
System Busy | System is in wait mode, system may have an internal problem |
CA | Alarm was canceled, this is not a trouble |
Canceled Alarm | Alarm was canceled, this is not a trouble |
CC | Panel is being downloaded by Tech Support |
Modem Comm | Panel is being downloaded by Tech Support |
94 | Telephone Line Failure |
Telco Fault | Telephone Line Failure |
70 | Siren supervision failure |
90 | RF Jam detected |
00 Bat | Wireless keypad low battery |
Cd | Phone test okay |
dO | Dialer off |
dd | Walk test is active (Code + 5 + 0) to exit |
dC | Download complete |
dF | Download failed |
Alarm xx | Zone is or was in alarm where xx is the zone number |
Fault xx | Zone is faulted where xx is the zone number |
Check xx | Zone is not communicating with the panel where xx is the zone number |
EA |
Exit Alarm, this is not a trouble, customer armed system then left and didn’t close door before delay expired |
FC | Fail to Communicate |
OC | Open Circuit, bad keypad wire |
Beep every 40 sec |
System is in Test Mode (Press Code + 1 to exit) |