Zones 22 Total, 6 Hardwired (1 to 6), 16 Wireless (9 to 24) 8 Soft (Keyfob only) zones, 49 to 56
Wireless Yes
Batteries
12 volt Rechargable inside main Panel, AC Transformer 16 volts
Door/Windows 3-Volt Lithium
Motion Sensor 2 3-Volt Lithium
Smoke Detector 2 9-volt Alkalines
Remote Keypads 3-Volt Lithium
Keyfobs 3-Volt Lithium
Remote Panics 9-Volt Lithium
Downloadable Yes (FA130CP)
Partitions 1
Panic Buttons Police Panic – * and #
Fire Panic – 1 and *
Medical Panic – 3 and #

Status Press * if keypad shows NOT READY to view open zones

Arm Away 4-digit code + 2 (AWAY) to arm everything

Arm Stay 4-digit code + 3 (STAY) to arm all but motions

Instant Arm 4-digit code + 7 (INSTANT), this also bypasses motions

Max Arming 4-digit code + 4 (MAX) and everything arms instant

Disarm 4 digit code + 1 (OFF)

Silence Alarm 4-digit code + 1 (OFF) twice to turn off siren and reset display
(If code is entered wrong, wait 2 or 3 seconds then try again)

Bypass 4-digit code + 6 (BYPASS) + zone (01, 02 03 etc)
(keypad will beep, BYPASS + Zone should show, arm system)

Reset Smoke 4-digit code +; 1 (OFF) twice to turn off siren and reset smoke
(If this does NOT reset smoke detector set for service, smoke is bad)

Door Chimes 4-digit code + 9 (CHIME)

Quick-Arm # + 2 for AWAY, # + 3 for STAY

Activate Relay 4-digit Code + # + 7
Deactivate Relay 4-digit Code + # + 8

Test Sensors 4-Digit Code + 5 (TEST)
Keypad will beep every 3 minutes
Open sensors and keypad will sound
End test with 4-digit Code + 1 (OFF) key
(Wireless motions require no movement for 4 minutes prior to testing)

Go/NoGo test (Verify signal strength)
1. Installer code # 4
2. Receiver gain is reduced by 50%
3. Keypad will beep 3 times to indicate signal reception
4. Enter 4-digit Code + 1 (OFF)

Pager Signals Alarm sends Account + 911 + 3 digit Zone
Open sends Account + 001 + 3 digit User
Close sends Account + 002 + 3 digit User
Trouble sends Account + 811 + 3 digit Zone

Must have alpha keypad and panel must be in normal operating mode for the following commands:

Event History Installer or Master code + # 6 + 0
Press *; to move forward
Press # to move backwards
Press 0 to exit

Date and Time Installer or Master code + # + 6 + 3
System will display current time
* to enter the correct time
Enter the 2 digit hour
Enter the 2 digit minute
Press 1 for PM or Press 2 for AM
Enter the 2 digit year
Enter the 2 digit month
Enter the 2 digit day
Press * to exit (# to backup if incorrect entry made)

Schedules Installer or Master code + # + 6 + 4
(See schedules for more information);;