Zones | 22 Total, 6 Hardwired (1 to 6), 16 Wireless (9 to 24) 8 Soft (Keyfob only) zones, 49 to 56 | ||||||||||||||
Wireless | Yes | ||||||||||||||
Batteries |
|
||||||||||||||
Downloadable | Yes (FA130CP) | ||||||||||||||
Partitions | 1 | ||||||||||||||
Panic Buttons |
Police Panic – * and # Fire Panic – 1 and * Medical Panic – 3 and # |
||||||||||||||
Status | Press * if keypad shows NOT READY to view open zones | ||||||||||||||
Arm Away | 4-digit code + 2 (AWAY) to arm everything | ||||||||||||||
Arm Stay | 4-digit code + 3 (STAY) to arm all but motions | ||||||||||||||
Instant Arm | 4-digit code + 7 (INSTANT), this also bypasses motions | ||||||||||||||
Max Arming | 4-digit code + 4 (MAX) and everything arms instant | ||||||||||||||
Disarm | 4 digit code + 1 (OFF) | ||||||||||||||
Silence Alarm |
4-digit code + 1 (OFF) twice to turn off siren and reset display (If code is entered wrong, wait 2 or 3 seconds then try again) |
||||||||||||||
Bypass |
4-digit code + 6 (BYPASS) + zone (01, 02 03 etc) (keypad will beep, BYPASS + Zone should show, arm system) |
||||||||||||||
Reset Smoke |
4-digit code +; 1 (OFF) twice to turn off siren and reset smoke (If this does NOT reset smoke detector set for service, smoke is bad) |
||||||||||||||
Door Chimes | 4-digit code + 9 (CHIME) | ||||||||||||||
Quick-Arm | # + 2 for AWAY, # + 3 for STAY | ||||||||||||||
Activate Relay | 4-digit Code + # + 7 | ||||||||||||||
Deactivate Relay | 4-digit Code + # + 8 | ||||||||||||||
Test Sensors |
4-Digit Code + 5 (TEST) Keypad will beep every 3 minutes Open sensors and keypad will sound End test with 4-digit Code + 1 (OFF) key (Wireless motions require no movement for 4 minutes prior to testing) |
||||||||||||||
Go/NoGo test |
(Verify signal strength) 1. Installer code # 4 2. Receiver gain is reduced by 50% 3. Keypad will beep 3 times to indicate signal reception 4. Enter 4-digit Code + 1 (OFF) |
||||||||||||||
Pager Signals |
Alarm sends Account + 911 + 3 digit Zone Open sends Account + 001 + 3 digit User Close sends Account + 002 + 3 digit User Trouble sends Account + 811 + 3 digit Zone |
||||||||||||||
Must have alpha keypad and panel must be in normal operating mode for the following commands: | |||||||||||||||
Event History |
Installer or Master code + # 6 + 0 Press *; to move forward Press # to move backwards Press 0 to exit |
||||||||||||||
Date and Time |
Installer or Master code + # + 6 + 3 System will display current time * to enter the correct time Enter the 2 digit hour Enter the 2 digit minute Press 1 for PM or Press 2 for AM Enter the 2 digit year Enter the 2 digit month Enter the 2 digit day Press * to exit (# to backup if incorrect entry made) |
||||||||||||||
Schedules |
Installer or Master code + # + 6 + 4 (See schedules for more information);; |