*20 Installer Code | I_6_I_3_I_2_I_1_I | |||||||||||||||||||||||
*21 Quick Arm Enable | I_1_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*22 RF System Type | I_0_I |
0 = None 1 = 5700 Receiver 2 = 5800 Receiver |
||||||||||||||||||||||
*23 Forced Bypass Enable | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*24 RF House Code | I_0_I_0_I | 00 = Disabled, 01 to 31 | ||||||||||||||||||||||
Used only with 5700 wireless, 5804BD and 5827BD | ||||||||||||||||||||||||
*25 Output Relay Module | I_0_I |
0 = None 3 = 4204 Relay Module |
||||||||||||||||||||||
*26 4285 Voice Module Access Code | I_0_I_0_I |
00 = Disabled 1st digit = 1 to 9 2nd digit = # + 11 = * or # + 12 = # |
||||||||||||||||||||||
*27 Output to Long Range Radio | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*28 Single Alarm Sounding/Zone | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*29 Fire Sounder Timeout | I_0_I |
0 = Timeout 1 = No Timeout |
||||||||||||||||||||||
*30 Alarm Bell Timeout | I_0_I |
0 = None 1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
||||||||||||||||||||||
*38 Entry Delay Exit Delay = Entry Delay + 15 seconds |
I_6_I_0_I |
|
||||||||||||||||||||||
*39 Audible Exit Warning | I_1_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*39 Power Up in Previous State | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*40 PABX Access Code | (4 digits) I_ _I_ _I_ _I_ _I | (If 9 is needed to dial add here) | ||||||||||||||||||||||
*41 Primary Phone |
(12 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause |
|||||||||||||||||||||||
*42 Secondary Phone | (12 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I | |||||||||||||||||||||||
*43 Primary Account |
(4 digits) I_ _I_ _I_ _I_ _I (Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15) |
|||||||||||||||||||||||
*45 Phone System Select | I_1_I |
0 = Pulse Dial 1 = DTMF Dial 2 = Pulse Dial, CS on Watts Line 3 = DTMF Dial, CS on Watts Line |
||||||||||||||||||||||
*46 Report Format | I_7_I |
0 = 3/1, 4/1 Ademco L/S Standard 1 = 3/1, 4/1 Radionics Standard 2 = 4/2 Ademco L/S Standard 3 = 4/2 Radionics Standard 6 = 4/2 Ademco Express 7 = Contact ID 8 = 3/1, 4/1 Ademco L/S Expanded 9 = 3/1, 4/1 Radionics Expanded |
||||||||||||||||||||||
*47 Split/Dual Reporting | I_0_I | |||||||||||||||||||||||
|
||||||||||||||||||||||||
*48 15 Second Dialer Delay (Burg) | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*49 Periodic Test Message | I_0_I |
0 = None 1 = 24 Hours 2 = Weekly 3 = Monthly |
||||||||||||||||||||||
*50 Sescoa/Radionics | I_0_I |
0 = Radionics 1 = Sescoa 0 = All Others |
||||||||||||||||||||||
*51 Confirm Arming Ding | I_0_I |
0 = No 1 = Yes 2 = Yes RF Only |
||||||||||||||||||||||
*52 Cancel Verify | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*53 Pager Phone Number | (20 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I | |||||||||||||||||||||||
*54 Pager Report Options | I_0_I | |||||||||||||||||||||||
|
||||||||||||||||||||||||
Must use 6139 Alpha Keypad here | ||||||||||||||||||||||||
*56 Zone Assignments | ||||||||||||||||||||||||
|
||||||||||||||||||||||||
1. At “Set to Confirm?” press 1 | ||||||||||||||||||||||||
2. “Enter Zn No.” enter which zone to program (01-87, 88-91, 95, 96, 97, 99) then press * | ||||||||||||||||||||||||
3. Keypad will show current programming for that zone, press * | ||||||||||||||||||||||||
4. “Zone Type?” enter type then * |
00 = Zone Disabled/Deleted 01 = Delay Zone 02 = Secondary Delay Zone 03 = Perimeter/Instant 04 = Interior Follower/Motions 05 = Trouble by Day/Alarm by Night 06 = 24 hour Silent/Holdup 07 = 24 hour Police Panic 08 = 24 hour Aux/Medical 09 = Fire 10 = Interior Delay 20 = Arm-Stay (RF only) 21 = Arm-Away (RF only) 22 = Disarm (RF only) 23 = No Alarm Response |
|||||||||||||||||||||||
5. “Response Time?” Enter 1 then * |
0 = 10msec 1 = 350ms 2 = 700ms |
|||||||||||||||||||||||
6. “Report Code?” enter 10 then * | ||||||||||||||||||||||||
7. “Input Device?” enter type then * |
1 for Hardwired 2 for Auxiliary Wired (with 4219/4229 Expander) 3 for Supervised RF (most sensors are RF) 4 for Un-Supervised RF 5 RF Button Type (Keyfobs/Panics etc) 6 Serial number polling loop devices 7 Dip Switch polling loop devices 8 Right Loop of DIP switch type device (4190 expander) |
|||||||||||||||||||||||
8. Cursor should flash above the loop number “LP#”, Enter 1 to 4 depending on sensor then * | ||||||||||||||||||||||||
|
||||||||||||||||||||||||
9. “Serial Prog?” press 1 and either enter the serial number or trip sensor twice | ||||||||||||||||||||||||
Note: Serial numbers found on sticker on sensor, if not, learn by tripping sensor | ||||||||||||||||||||||||
10. “Alpha Program?” press 0 if No, 1 to program Alpha Zone Descriptions | ||||||||||||||||||||||||
11. ” Keypad will show either new summary for zone or “Enter zone number” | ||||||||||||||||||||||||
12. If finished programming enter 00 at “Enter zone no” to return to normal programming | ||||||||||||||||||||||||
*60 Trouble Report Code | I_1_I_0_I | |||||||||||||||||||||||
*61 Bypass Report Code | I_0_I_0_I | |||||||||||||||||||||||
*62 AC Loss Report Code | I_0_I_0_I | |||||||||||||||||||||||
*63 Low Bat Report Code | I_1_I_0_I | |||||||||||||||||||||||
*64 Test Report Code | I_0_I_0_I | |||||||||||||||||||||||
*65 Open Report / Exit Alarm | I_0_I_0_I | |||||||||||||||||||||||
*66 Away/Stay Report |
I_0_I Away I_0_I Stay |
|||||||||||||||||||||||
*67 RF Xmtr Low Bat | I_0_I_0_I | |||||||||||||||||||||||
*68 Cancel Report Code | I_1_I_0_I | |||||||||||||||||||||||
*70 Alarm Restore Code | I_0_I | |||||||||||||||||||||||
*71 Trouble Restore Code | I_0_I_0_I | |||||||||||||||||||||||
*72 Bypass Restore Code | I_0_I_0_I | |||||||||||||||||||||||
*73 AC Restore Code | I_0_I_0_I | |||||||||||||||||||||||
*74 Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||||||||
*75 RF Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||||||||
*80 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||||||||||||||||||||||
*81 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||||||||||||||||||||||
*82 Custom Alpha Editing | ||||||||||||||||||||||||
*83 Add/Delete 5800 RF Input ID | ||||||||||||||||||||||||
*91 Option Selection | I_0_I |
0 = None 4 = AAV 2-way module enabled |
||||||||||||||||||||||
*92 Reports Per Armed Period | I_0_I |
0 = 10 Alarms per Armed period 1 = Unlimited Alarms |
||||||||||||||||||||||
*94 Download Phone | (20 digits) I_1_I_8_I_0_I_0_I_6_I_8_I_2_I_1_I_6_I_9_I_0_I_ _I | |||||||||||||||||||||||
*95 Ring Count | I_# 15_I | 0 to #15 #15 = Answer Machine | ||||||||||||||||||||||
*96 Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s) | ||||||||||||||||||||||||
*97 Default Panel (No Value needed, keypad will beep and default panel) | ||||||||||||||||||||||||
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) | ||||||||||||||||||||||||
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) |