Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 20)
or Power down then back up and press * and # within 1 minute
(If exiting programming you can re-enter within 1 minute by pressing * and #)
Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00
Move to Location * + Location
View Location # + Location (Display will read off one digit at a time)
Default panel CLICK HERE

*20 Installer Code I_6_I_3_I_2_I_1_I
*21 Quick Arm Enable I_1_I 0 = No
1 = Yes

*22 RF System Type I_0_I 0 = None
1 = 5700 Receiver
2 = 5800 Receiver

*23 Forced Bypass Enable I_0_I 0 = No
1 = Yes

*24 RF House Code I_0_I_0_I 00 = Disabled, 01 to 31
Used only with 5700 wireless, 5804BD and 5827BD

*25 Output Relay Module I_0_I 0 = None
3 = 4204 Relay Module

*26 4285 Voice Module Access Code I_0_I_0_I 00 = Disabled
1st digit = 1 to 9
2nd digit = # + 11 = * or # + 12 = #

*27 Output to Long Range Radio I_0_I 0 = No
1 = Yes

*28 Single Alarm Sounding/Zone I_0_I 0 = No
1 = Yes

*29 Fire Sounder Timeout I_0_I 0 = Timeout
1 = No Timeout

*30 Alarm Bell Timeout I_0_I 0 = None
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
4 = 16 minutes

*38 Entry Delay
Exit Delay = Entry Delay + 15 seconds
I_6_I_0_I 0 = 0 seconds
3 = 45 seconds
1 = 20 seconds 4 = 60 seconds
2 = 30 seconds 5 = 90 seconds
*39 Audible Exit Warning I_1_I 0 = No
1 = Yes

*39 Power Up in Previous State I_0_I 0 = No
1 = Yes

*40 PABX Access Code (4 digits) I_ _I_ _I_ _I_ _I (If 9 is needed to dial add here)

*41 Primary Phone (12 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

*42 Secondary Phone (12 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

*43 Primary Account (4 digits) I_ _I_ _I_ _I_ _I
(Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15)

*45 Phone System Select I_1_I 0 = Pulse Dial
1 = DTMF Dial
2 = Pulse Dial, CS on Watts Line
3 = DTMF Dial, CS on Watts Line

*46 Report Format I_7_I 0 = 3/1, 4/1 Ademco L/S Standard
1 = 3/1, 4/1 Radionics Standard
2 = 4/2 Ademco L/S Standard
3 = 4/2 Radionics Standard
6 = 4/2 Ademco Express
7 = Contact ID
8 = 3/1, 4/1 Ademco L/S Expanded
9 = 3/1, 4/1 Radionics Expanded

*47 Split/Dual Reporting I_0_I
To Primary Phone To Secondary Phone
0 = All reports Backup Only
1 = Alarms, Restore, Cancel All Other Reports
2 = All Reports except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All Reports
4 = All Reports except Open/Close, Test All Reports
5 = All Reports (Dual Reporting) All Reports
6 = All reports except Open/Close Alarms, Open/Close, Troubles
7 = All reports Alarms, Troubles
8 = All reports Alarms, Open/Close, Troubles
9 = All reports except Open/Close Alarms, Open/Close for Users 5-8
*48 15 Second Dialer Delay (Burg) I_0_I 0 = No
1 = Yes

*49 Periodic Test Message I_0_I 0 = None
1 = 24 Hours
2 = Weekly
3 = Monthly

*50 Sescoa/Radionics I_0_I 0 = Radionics
1 = Sescoa
0 = All Others

*51 Confirm Arming Ding I_0_I 0 = No
1 = Yes
2 = Yes RF Only

*52 Cancel Verify I_0_I 0 = No
1 = Yes

*53 Pager Phone Number (20 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

*54 Pager Report Options I_0_I
0 = No Reports Sent
1 = Opening/Closings for All Users
3 = Open/Close users 5 to 16, wireless
key zones entered in Zone list 6/7
4 = All alarms and Troubles
5 = All Alarms, Troubles, Open/Close
7 = All Alarms, Troubles, Open/Close
Users 5 to 16,, Wireless Zones in list 6/7
12 = Alarms & Troubles for Zones in list 6/7
13 = Alarms & Troubles for zones in list 6
Open/Close for all users
15 = All Alarms & Troubles for Zones in list 6/7
Open/Close users 5 to 16 and wireless
keys entered in Zone List 6/7
Must use 6139 Alpha Keypad here
*56 Zone Assignments
Hardwired Zone 01 to 06 4-Wire Smokes Zone 5 only
Police Panic Zone 07
Duress Zone 08
Expander Trouble/Tamper Zone 09
Wireless Zone 10 to 25
Fire Panic Zone 95
Medical Panic Zone 96
1. At “Set to Confirm?” press 1
2. “Enter Zn No.” enter which zone to program (01-87, 88-91, 95, 96, 97, 99) then press *
3. Keypad will show current programming for that zone, press *
4. “Zone Type?” enter type then * 00 = Zone Disabled/Deleted
01 = Delay Zone
02 = Secondary Delay Zone
03 = Perimeter/Instant
04 = Interior Follower/Motions
05 = Trouble by Day/Alarm by Night
06 = 24 hour Silent/Holdup
07 = 24 hour Police Panic
08 = 24 hour Aux/Medical
09 = Fire
10 = Interior Delay
20 = Arm-Stay (RF only)
21 = Arm-Away (RF only)
22 = Disarm (RF only)
23 = No Alarm Response

5. “Response Time?” Enter 1 then * 0 = 10msec
1 = 350ms
2 = 700ms

6. “Report Code?” enter 10 then *

7. “Input Device?” enter type then * 1 for Hardwired
2 for Auxiliary Wired (with 4219/4229 Expander)
3 for Supervised RF (most sensors are RF)
4 for Un-Supervised RF
5 RF Button Type (Keyfobs/Panics etc)
6 Serial number polling loop devices
7 Dip Switch polling loop devices
8 Right Loop of DIP switch type device (4190 expander)

8. Cursor should flash above the loop number “LP#”, Enter 1 to 4 depending on sensor then *
Door Switch – Loop 1 = External Sensor Connector
– Loop 2 = Internal Reed Switch
Glassbreak – Loop 1
Smoke Detectors – Loop 1
Motions – Loop 1
Keyfobs – Loop 1 = Bottom Right Button (Each button counts as 1 zone)
– Loop 2 = Top Right Button
– Loop 3 = Top Left Button
– Loop 4 = Bottom Left Button
9. “Serial Prog?” press 1 and either enter the serial number or trip sensor twice
Note: Serial numbers found on sticker on sensor, if not, learn by tripping sensor
10. “Alpha Program?” press 0 if No, 1 to program Alpha Zone Descriptions
11. ” Keypad will show either new summary for zone or “Enter zone number”
12. If finished programming enter 00 at “Enter zone no” to return to normal programming

*60 Trouble Report Code I_1_I_0_I
*61 Bypass Report Code I_0_I_0_I
*62 AC Loss Report Code I_0_I_0_I
*63 Low Bat Report Code I_1_I_0_I
*64 Test Report Code I_0_I_0_I
*65 Open Report / Exit Alarm I_0_I_0_I

*66 Away/Stay Report I_0_I Away
I_0_I Stay

*67 RF Xmtr Low Bat I_0_I_0_I
*68 Cancel Report Code I_1_I_0_I
*70 Alarm Restore Code I_0_I
*71 Trouble Restore Code I_0_I_0_I
*72 Bypass Restore Code I_0_I_0_I
*73 AC Restore Code I_0_I_0_I
*74 Low Bat Rest Code I_0_I_0_I
*75 RF Low Bat Rest Code I_0_I_0_I
*80 Output Relays (Usually program only if 4204 Relay is enabled in *25)
*81 Output Relays (Usually program only if 4204 Relay is enabled in *25)
*82 Custom Alpha Editing
*83 Add/Delete 5800 RF Input ID

*91 Option Selection I_0_I 0 = None
4 = AAV 2-way module enabled

*92 Reports Per Armed Period I_0_I 0 = 10 Alarms per Armed period
1 = Unlimited Alarms

*94 Download Phone (20 digits) I_1_I_8_I_0_I_0_I_6_I_8_I_2_I_1_I_6_I_9_I_0_I_ _I
*95 Ring Count I_# 15_I 0 to #15 #15 = Answer Machine

*96 Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s)
*97 Default Panel (No Value needed, keypad will beep and default panel)
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0)
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0)