*20 Installer Code | I_6_I_3_I_2_I_1_I | |||||||||||||||||||||||
*21 Quick Arm Enable | I_1_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*22 RF System Type | I_0_I |
0 = None 2 = 5800 Wireless 4 = 5800 Wireless |
||||||||||||||||||||||
*23 Forced Bypass Enable | I_0_I |
0 = No 1 = Yes bypass open Zones |
||||||||||||||||||||||
*24 RF House Code | I_0_I_0_I | 00 = Disabled, 01 to 31 | ||||||||||||||||||||||
*25 Wired Expansion Module | I_0_I |
0 = None 1 = 4204 Relay Module |
||||||||||||||||||||||
*26 Voice Module Access Code | I_0_I_0_I |
00 = Disabled 1st digit = 1 to 9 2nd digit = # + 11 = * or # + 12 = # |
||||||||||||||||||||||
*27 Output to Long Range Radio | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*28 Single Alarm Sounding/Zone | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*29 Fire Sounder Timeout | I_0_I |
0 = Timeout 1 = No Timeout |
||||||||||||||||||||||
*30 Alarm Bell Timeout | I_0_I |
0 = None 1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
||||||||||||||||||||||
*36 Exit Delay | I_6_I_0_I | 00 to 99 Seconds | ||||||||||||||||||||||
*37 Entry Delay 1 | I_4_I_5_I | 00 to 99 Seconds | ||||||||||||||||||||||
*38 Entry Delay 2 | I_1_I_0_I | 00 to 99 Seconds | ||||||||||||||||||||||
*39 Audible Exit Warning | I_1_I Partition 1 |
0 = No 1 = Yes |
||||||||||||||||||||||
*40 PABX Access Code (6 digits) | I_ _I_ _I_ _I_ _I_ _I_ _I | (If 9 is needed to dial add here) | ||||||||||||||||||||||
*41 Primary Phone (20 digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause |
|||||||||||||||||||||||
*42 Secondary Phone (20 digits) | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I | |||||||||||||||||||||||
*43 Primary Account |
I_ _I_ _I_ _I_ _I (Last 4 of Account) A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 |
|||||||||||||||||||||||
*45 Phone System Select | I_3_I |
0 = Pulse Dial 1 = DTMF Dial 2 = Pulse Dial, CS on Watts Line 3 = DTMF Dial, CS on Watts Line |
||||||||||||||||||||||
*Report Format is hard coded to Contact ID* | ||||||||||||||||||||||||
*47 Split/Dual Reporting | I_0_I | |||||||||||||||||||||||
|
||||||||||||||||||||||||
*48 15 Second Dial Delay | I_1_I |
0 = No 1 = Yes |
||||||||||||||||||||||
*49 Periodic Test Message | I_3_I |
0 = None 1 = 24 Hours 2 = Weekly 3 = Monthly |
||||||||||||||||||||||
*51 Confirmation of Arming Ding | I_0_I |
0 = No 1 = Yes 2 = Yes with RF Only |
||||||||||||||||||||||
*52 Zone 3 Response to Open | I_0_I |
0 = 400ms 1 = 10ms |
||||||||||||||||||||||
*53 Zone Type 25 Response Time | I_0_I |
0 = Disabled 1 to F = 1 to 15 Minutes |
||||||||||||||||||||||
(Must use 6139 Alpha Keypad here) | ||||||||||||||||||||||||
*56 Zone Assignments (Max 24 hardwired and/or wireless zones in addition to the 8 onboard zones) | ||||||||||||||||||||||||
Hardwired Zone Expander Trouble/Tamper Wireless Duress Fire Panic Medical Panic Police Panic |
01 to 06 4-Wire Smokes Zone 5 only Zone 09 Zone 10 to 25 (Depends on capacity of 5881 receiver) Zone 08 Zone 95 Zone 96 | |||||||||||||||||||||||
1. At “Program Tool?” press 0, if it shows “Set to Confirm?” press 1 | ||||||||||||||||||||||||
2. “Enter Zn No.” enter which zone to program (01-87, 88-91, 95, 96, 97, 99) press * | ||||||||||||||||||||||||
3. Keypad will show summary zones programming, press * | ||||||||||||||||||||||||
4. “Zone Type?” enter type then * |
00 = Zone Disabled/Deleted 01 = Delay Zone 02 = Secondary Delay Zone 03 = Perimeter/Instant 04 = Interior Follower/Motions 05 = Trouble by Day/Alarm by Night 06 = 24 hour Silent/Holdup 07 = 24 hour Police Panic 08 = 24 hour Aux/Medical 09 = Fire 10 = Interior Delay 20 = Arm-Stay (RF only) 21 = Arm-Away (RF only) 22 = Disarm (RF only) 23 = No Alarm Response |
|||||||||||||||||||||||
5. “Report Code?” enter report code for zone | ||||||||||||||||||||||||
6. “Input Device?” enter device then * |
1 = Hardwired 2 = Auxiliary Wired (with 4219/4229 Expander) 3 = Supervised RF (most sensors are RF) 4 = Un-Supervised RF 5 = RF Button Type (Keyfobs/Panics etc) 6 = Serial number polling loop devices 7 = Dip Switch polling loop devices 8 = Right Loop of DIP switch type device (4190 expander) |
|||||||||||||||||||||||
7. Cursor should flash above the loop number “LP#”, Enter 1 to 4 depending on sensor | ||||||||||||||||||||||||
(New version Vista-20SE will ask for Loop Number AFTER learning sensor) | ||||||||||||||||||||||||
Door Switch |
– Loop 1 = External Sensor Connector – Loop 2 = Internal Reed Switch |
|||||||||||||||||||||||
Glassbreak | – Loop 1 | |||||||||||||||||||||||
Smoke Detectors | – Loop 1 | |||||||||||||||||||||||
Motions | – Loop 1 | |||||||||||||||||||||||
Keyfobs |
– Loop 1 = Bottom Right Button (Each button counts as 1 zone) – Loop 2 = Top Right Button – Loop 3 = Top Left Button – Loop 4 = Bottom Left Button |
|||||||||||||||||||||||
8. “Serial Prog?” press 1 and either enter the serial number or trip sensor twice | ||||||||||||||||||||||||
(Serial numbers found on sticker on sensor, if not, learn by tripping sensor) | ||||||||||||||||||||||||
9. “Alpha Program?” press 0 if not programming Alpha descriptions | ||||||||||||||||||||||||
10. ” Keypad will show either new summary for zone or “Enter zone number” | ||||||||||||||||||||||||
11. If finished programming enter 00 at “Enter zone no” to return to normal programming | ||||||||||||||||||||||||
*60 Trouble Report Code | I_1_I_0_I | |||||||||||||||||||||||
*61 Bypass Report Code | I_0_I_0_I | |||||||||||||||||||||||
*62 AC Loss Report Code | I_1_I_0_I | |||||||||||||||||||||||
*63 Low Bat Report Code | I_1_I_0_I | |||||||||||||||||||||||
*64 Test Report Code | I_0_I_0_I | |||||||||||||||||||||||
*65 Open Report Code / Exit Alarm | I_0_I_0_I | |||||||||||||||||||||||
*66 Away/Stay Report | I_0_I_0_I | |||||||||||||||||||||||
*67 RF Xmtr Low Bat | I_0_I_0_I | |||||||||||||||||||||||
*68 Cancel Report Code | I_1_I_0_I | |||||||||||||||||||||||
*70 Alarm Restore Code | I_0_I | |||||||||||||||||||||||
*71 Trouble Restore Code | I_0_I_0_I | |||||||||||||||||||||||
*72 Bypass Restore Code | I_0_I_0_I | |||||||||||||||||||||||
*73 AC Restore Code | I_0_I_0_I | |||||||||||||||||||||||
*74 Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||||||||
*75 RF Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||||||||
*80 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||||||||||||||||||||||
*81 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||||||||||||||||||||||
*82 Custom Alpha Editing (Do not Program) | ||||||||||||||||||||||||
*83 Sequential Mode (Alternate way of programming sensors, not used) | ||||||||||||||||||||||||
*89 Event Log 80% Full | I_0_I_0_I | |||||||||||||||||||||||
*90 Pager Characteristics (16 digits) | I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I | |||||||||||||||||||||||
*91 Option Selection | I_0_I |
0 = None 1 = Bell Supervision 4 = AAV 2-way 5 = AAV 2-way + Bell Supervision 8 = Exit Delay Restart 9 = Exit Delay Restart + Bell Supervision 12 = AAV + Exit Delay Restart 13 = Bell Supervision + AAV + Exit Delay Restart |
||||||||||||||||||||||
*92 Reports per Armed Period | I_0_I |
0 = 10 per Armed period 1 = Unlimited per Armed period |
||||||||||||||||||||||
*94 Download Phone Number | I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I_ _I | |||||||||||||||||||||||
*95 Ring Count | I_# 15_I | 0 to #15 #15 = Answer Machine Defeat | ||||||||||||||||||||||
*96 Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s) | ||||||||||||||||||||||||
*97 Default Panel (No Value needed, keypad will beep and default panel) | ||||||||||||||||||||||||
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) | ||||||||||||||||||||||||
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) |