Ademco Vista 100 Basics
Zones | 8 Hardwired, up to 87 Hardwired or Wireless | ||
Wireless | Yes | ||
Battery |
|
||
Partitions | 8 | ||
Downloadable | Yes | ||
Panic Buttons |
|
||
Status | Press * if keypad shows NOT READY to view open zones | ||
Arm Away | 4-digit code + 2 (AWAY) to arm everything | ||
Arm Stay | 4-digit code + 3 (STAY) | ||
Instant Arm | 4 digit code + 7 (INSTANT), also bypasses motions | ||
Quick-Arm | # + 2 for AWAY, # + 3 for STAY (If Enabled) | ||
Max Arming | 4-digit code + 4 (MAX), arms everything including motions instant | ||
Disarm | 4 digit code + 1 key (OFF) | ||
Silence | Alarm 4-digit code + 1 (OFF) twice to turn off siren and reset display | ||
Bypass | 4-digit code + 6 (BYPASS) + Zone (01, 02 03 etc) (Three digit zone on Vista-100 or higher ie, zone 001) | ||
Quick Bypass | (if enabled) 6 (BYPASS) + Zone to bypass (01, 02 03 etc) (Three digit zone on Vista-100 or higher ie, zone 001) | ||
Door Chimes | 4-digit code + 9 (CHIME) | ||
Reset Smoke |
4-digit code + 1 (OFF) twice (If this does NOT reset smoke detector set for service, smoke is bad) |
||
Alarm Memory |
1. 4-digit code + # + 6 + 0, select 0 for Recent or 1 for Complete log 2. Select Partition (press 0 for all partitions) 3. Use 1 for previous log entries or 3 for next log entries 4. Press 8 to select a catagory and 8 again for next entry 5. Press * to exit |
||
Test Sensors |
4-digit Code + 5 (TEST) Keypad will beep every 3 minutes Open sensors and keypad will sound End test with 4-digit Code + 1 (OFF) key (Wireless motions require no movement for 4 minutes prior to testing) |
||
Setting Clock |
(some systems may not allow changing Clock) 1. Enter Master Code + # + 63, display will show current Time/Date 2. Enter correct (00 to 12) Hour then press * 3. Enter correct Minutes (00 to 59) then press * 4. Press any key from 0 to 9 to toggle AM and PM then press * 5. Enter correct Month (01 to 12) then press * 6. Enter correct Date (01 to 31) then press * 7. Enter correct Year (99 or 00 etc) then press * 8. Press * after cursor is in the Year setting to exit |
||
Access Partition | User Code + * and Partition (0, 1, 2 etc) | ||
View Message | Hold 0 for 5 seconds to view Monitoring Station Messages | ||
View User Info | 4 digit code + ** to display Authority and Partition levels | ||
Display Zones | Hold * for 5 seconds to view all zone descriptions | ||
Go/NoGo Test |
Installer code 5, Receiver gain is reduced by 50% (Keypad will beep 3 times to indicate signal reception) |