Enter Program |
4111 + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) |
Move to Location | * + Location |
View Location | # + Location (Display will read off one digit at a time) |
Exit Program | 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00 |
Test Timer | *49 Periodic Test I_3_I 1=24 hrs 2= Weekly 3= Monthly *64 Test Report Code I_1_I_0_I |
|
||||||||||||||||||||||
*20 Installer Code | I_4_I_1_I_1_I_1_I | |||||||||||||||||||||
*21 Quick Arm Enable | I_1_I |
0 = No 1 = Yes |
||||||||||||||||||||
*22 RF (Wireless) System Type | I_0_I |
0=None 1=5700 wireless with 4281 Receiver 2=5800 wireless with 5881 receiver 4=5800 wireless RF Jamming |
||||||||||||||||||||
Panel treats 5700 wireless as hardwire zones 4281L receiver adds 4 zones (Zones 10 to 13) 4281M and 4281H add 8 zones (Zones 10 to 17) (1 available on Via-30/SE v14 and below) (4 available on Via-30/SE v13 and above) |
||||||||||||||||||||||
*23 Force Bypass Enable | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||
*24 RF House Code | I_0_I_0_I | 00 = Disabled, 01-31 | ||||||||||||||||||||
Used only with 5700 series wireless, 5804BD keyfob and 5827BD Keypad | ||||||||||||||||||||||
*25 Wired Expansion/Relay | I_0_I |
0 = None 1 = 4219 8-Zone Expander 2 = 4229 8-Zone Expander/Relay 3 = 4204 Relay Module |
||||||||||||||||||||
*26 4284/4285 Voice Module Code | I_0_I_0_I |
00 = Disabled 1st digit = 1 to 9 2nd digit = # + 11 = * or # + 12 = # |
||||||||||||||||||||
*27 Output to Long Range Radio | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||
*28 Single Alarm Sound/Zone | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||
*29 Fire Sounder Timeout | I_1_I |
0 = Yes 1 = No Fire Timeout |
||||||||||||||||||||
*30 Alarm Bell Timeout | I_2_I |
0 = No Timeout 1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
||||||||||||||||||||
*38 Entry Delay Exit Delay = Entry + 15 seconds |
I_2_I |
1 = 20 seconds 2 = 30 seconds 3 = 45 seconds 4 = 60 seconds 5 = 90 seconds |
||||||||||||||||||||
*39 Audible Exit Warning | I_1_I |
0 = No 1 = Yes |
||||||||||||||||||||
*40 PABX Access Code | I_ _I_ _I_ _I_ _I | (If 9 is needed to dial add here) | ||||||||||||||||||||
*41 Primary Phone (12 digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause |
|||||||||||||||||||||
*42 Secondary Phone |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Pager will not work if Account Number starts with 0) |
|||||||||||||||||||||
*43 Subscriber Account |
I_ _I_ _I_ _I_ _I (Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15) |
|||||||||||||||||||||
*45 Phone Sys Select | I_1_I |
0 = Pulse Dial 1 = DTMF Dial 2 = Pulse Dial, CS on Watts Line 3 = DTMF Dial, CS on Watts Line |
||||||||||||||||||||
*46 Report Format | I_7_I |
0 = 3/1, 4/1 Ademco L/S Standard 1 = 3/1, 4/1 Radionics Standard 2 = 4/2 Ademco L/S Standard 3 = 4/2 Radionics Standard 6 = 4/2 Ademco Express 7 = Contact ID 8 = 3/1, 4/1 Ademco L/S Expanded 9 = 3/1, 4/1 Radionics Expanded |
||||||||||||||||||||
*47 Split/Dual Reporting | I_0_I | |||||||||||||||||||||
|
||||||||||||||||||||||
*48 15 Sec Burg Dial Delay | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||
*49 Periodic Test Message | I_0_I |
0 = None 1 = 24 Hours 2 = Weekly 3 = Monthly |
||||||||||||||||||||
*50 Sescoa/Radionics | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||
*51 Confirmation of Arming Ding | I_0_I |
0 = No 1 = Yes 2 = Yes for RF Arming |
||||||||||||||||||||
Must use 6139 Alpha Keypad here | ||||||||||||||||||||||
*56 Zone Assignments | (Max 30 wireless zones in addition to the 2 onboard zones) | |||||||||||||||||||||
|
||||||||||||||||||||||
1. At “Program Tool?” press 0, if “Set to Confirm?” press 1 | ||||||||||||||||||||||
2. “Enter Zn No.” enter zone to program (01-87, 88-91, 95, 96, 97, 99), press * | ||||||||||||||||||||||
3. Keypad will show summary of zones programming, press * | ||||||||||||||||||||||
4. “Zone Type?” enter type then * |
00 = Zone Disabled/Deleted 01 = Delay Zone 02 = Do not Use 03 = Perimeter/Instant 04 = Interior Follower/Motions 05 = Trouble by Day/Alarm by Night 06 = 24 hour Silent/Holdup 07 = 24 hour Police Panic 08 = 24 hour Aux/Medical 09 = Fire 10 = Interior Delay 20 = Arm-Stay (RF only) 21 = Arm-Away (RF only) 22 = Disarm (RF only) 23 = No Alarm Response |
|||||||||||||||||||||
5. “Report Code?” enter 10 then * | ||||||||||||||||||||||
6. “Input Device?” enter device then * |
1 for Hardwired 2 for Auxiliary Wired (with 4219/4229 Expander) 3 for Supervised RF (most sensors are RF) 4 for Un-Supervised RF 5 RF Button Type (Keyfobs/Panics etc) |
|||||||||||||||||||||
(New versions may skip step 7 and move to step 8, learn Loop number after learning sensor) | ||||||||||||||||||||||
7. Cursor should flash above “LP#”, Enter Loop number 1 to 4 depending on sensor | ||||||||||||||||||||||
|
||||||||||||||||||||||
8. “Serial Prog?” press 1 and either enter serial number or trip sensor twice | ||||||||||||||||||||||
Note: Serial numbers found on sticker on of sensor, if not, learn by tripping sensor | ||||||||||||||||||||||
9. “Alpha Program?” press 0 if not programming Alpha descriptions | ||||||||||||||||||||||
10. ” Keypad shows new summary of programming or be back to “Enter zone number” | ||||||||||||||||||||||
11. If finished programming zones enter 00 at “Enter zone no” to return to normal programming | ||||||||||||||||||||||
*60 Trouble Report Code | I_1_I_0_I | |||||||||||||||||||||
*61 Bypass Report Code | I_0_I_0_I | |||||||||||||||||||||
*62 AC Loss Report Code | I_1_I_0_I | |||||||||||||||||||||
*63 Low Bat Report Code | I_1_I_0_I | |||||||||||||||||||||
*64 Test Report Code | I_0_I_0_I | |||||||||||||||||||||
*65 Open (Disarm) Report/Exit Alarm |
I_0_I Opening Report I_0_I Exit Alarm |
|||||||||||||||||||||
*66 Away/Stay Report |
I_0_I Away I_0_I Stay |
|||||||||||||||||||||
*67 RF Xmtr Low Bat | I_0_I_0_I | |||||||||||||||||||||
*68 Cancel Report Code | I_1_I_0_I | |||||||||||||||||||||
*69 Group Restores for Trouble |
I_0_I RF Low Bat, Bypass |
|||||||||||||||||||||
*70 Alarm Restore Code | I_0_I | |||||||||||||||||||||
*71 Trouble Restore Code | I_0_I_0_I | |||||||||||||||||||||
*72 Bypass Restore Code | I_0_I_0_I | |||||||||||||||||||||
*73 AC Restore Code | I_0_I_0_I | |||||||||||||||||||||
*74 Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||||||
*75 RF Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||||||
*80 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||||||||||||||||||||
*81 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||||||||||||||||||||
*82 Custom Alpha Editing (Do not Program) | ||||||||||||||||||||||
*83 Sequential Mode (Alternate way of programming sensors, not used) | ||||||||||||||||||||||
*91 Option Selection | I_0_I |
0 = None 4 = AAV 2-way module enable (4 turns off siren during 2-way) |
||||||||||||||||||||
*92 Reports per Armed Period | I_0_I |
0 = 10 per armed period 1 = Unlimited per Armed period |
||||||||||||||||||||
*93 Dynamic Signaling Delay (Revision 15 and higher) |
I_0_I 1st Digit |
|
||||||||||||||||||||
I_0_I 2nd Digit |
0 = Primary Dialer First (Alarmnet is secondary) 1 = Long Range Radio First (Alarmnet is primary) |
|||||||||||||||||||||
*94 Download Phone Number | I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I_ _I | |||||||||||||||||||||
*95 Ring Count | I_# 15_I | 0 to #15 #15 = Answer Machine | ||||||||||||||||||||
*96 Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s) | ||||||||||||||||||||||
*97 Default Panel (No Value needed, keypad will beep and default panel) | ||||||||||||||||||||||
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) | ||||||||||||||||||||||
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) |