Zones | 2 Hardwired, up to 30 Wireless | ||||||||||||
Batteries | 12 volt rechargeable inside main panel, AC Transformer is 16 volts | ||||||||||||
|
|||||||||||||
Downloadable | Yes | ||||||||||||
Panic Buttons |
Police Panic – * and # Fire Panic – 1 and * Medical Panic – 3 and # |
||||||||||||
Status | Press * if keypad shows NOT READY to view open zones | ||||||||||||
Arm AWAY | 4-digit code + 2 (AWAY | ||||||||||||
Arm Stay | 4-digit code + 3 (STAY) | ||||||||||||
Disarm | 4 digit code + 1 (OFF) | ||||||||||||
Quick-Arm | Press # + 2 for AWAY, # + 3 for STAY | ||||||||||||
Instant Arm | 4 digit code + 7 (INSTANT) | ||||||||||||
Max Arming | 4-digit code + 4 (MAX) to arm everything Instant | ||||||||||||
Silence Alarm | 4-digit code + 1 (OFF) twice to turn off siren and reset display | ||||||||||||
(If code is entered wrong, wait 2 or 3 seconds then try again) | |||||||||||||
Door Chimes | 4-digit code + 9 (CHIME) | ||||||||||||
Bypass | 4-digit code + 6 (BYPASS) + zone (01, 02 03 etc) | ||||||||||||
Alarm Memory | There is no alarm memory | ||||||||||||
Reset Smoke | 4-digit code + 1 (OFF) twice to turn off siren and reset smoke | ||||||||||||
(If this does NOT reset smoke detector set for service, smoke is bad) | |||||||||||||
Test Sensors |
4-Digit Code + 5 (TEST) Keypad will beep every 3 minutes Open sensors and keypad will sound End test with 4-digit Code + 1 (OFF) key (Wireless motions require no movement for 4 minutes prior to testing) |
||||||||||||
Activate Relay | 4-digit Code + # + 7 | ||||||||||||
Deactivate Relay | 4-digit Code + # + 8 | ||||||||||||
Pager Signals |
Only available on Vista-10SE (not older Vista-10) Alarms Account + 1911 + 3 digit Zone # Openings Account + 1001 + 3 digit User # Closings Account + 1002 + 3 digit User # Trouble Account + 1811 + 3 digit Zone # |