*20 Master Code | I_4_I_1_I_1_I_1_I | |||||||||||||||||
*21 Quick Arm Enable | I_1_I |
0 = No 1 = Yes |
||||||||||||||||
*22 RF System Type | I_2_I | 0=None | ||||||||||||||||
Panel treats 5700 wireless as hardwire 1=5700 wireless receiver (Old stuff) 4281L receiver adds 4 zones 2=5800 wireless receiver 4281M and 4281H add 8 zones |
||||||||||||||||||
*23 Force Bypass Enable | I_0_I |
0 = No 1 = Yes |
||||||||||||||||
*24 RF House Code | I_0_I_0_I | 00 = Disabled, 01 to 31 | ||||||||||||||||
Used only with 5700 series wireless, 5804BD keyfob and 5827BD Keypad | ||||||||||||||||||
*25 Wired Expansion/Relay | I_0_I |
0 = None 1 = 4219 8-Zone Expander 2 = 4229 8-Zone Exp Relay 3 = 4204 Relay Module |
||||||||||||||||
*26 4284/4285 Voice Module Code | I_0_I_0_I |
00 = Disabled 1st digit = 1 to 9 2nd digit = # + 11 = * or # + 12 = # |
||||||||||||||||
*27 Output to Long Range Radio | I_0_I |
0 = No 1 = Yes |
||||||||||||||||
*28 Single Alarm Sound/Zone | I_0_I |
0 = No 1 = Yes |
||||||||||||||||
*29 Fire Sounder Timeout | I_1_I |
0 = Yes 1 = No Fire Timeout |
||||||||||||||||
*30 Alarm Bell Timeout | I_2_I |
0 = None 1 = 4 minutesa 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
||||||||||||||||
*38 Entry Delay Exit Delay = Entry + 15 seconds |
I_2_I |
1 = 20 seconds 2 = 30 seconds 3 = 45 seconds 4 = 60 seconds 5 = 90 seconds |
||||||||||||||||
*39 Audible Exit Warning | I_1_I |
0 = No 1 = Yes |
||||||||||||||||
*40 PABX Access Code | I_ _I_ _I_ _I_ _I | (If 9 is needed to dial add here) | ||||||||||||||||
*41 Primary Phone (12 digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause |
|||||||||||||||||
*42 Secondary Phone |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (This panel cannot do pagers) |
|||||||||||||||||
*43 Subscriber Account |
I_ _I_ _I_ _I_ _I Note: Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 |
|||||||||||||||||
*45 Phone System Select | I_1_I |
0 = Pulse Dial 1 = DTMF Dial 2 = Pulse Dial, CS on Watts Line 3 = DTMF Dial, CS on Watts Line |
||||||||||||||||
*46 Report Format | I_7_I |
0 = 3/1, 4/1 Ademco L/S Standard 1 = 3/1, 4/1 Radionics Standard 2 = 4/2 Ademco L/S Standard 3 = 4/2 Radionics Standard 6 = 4/2 Ademco Express 7 = Contact ID 8 = 3/1, 4/1 Ademco L/S Expanded 9 = 3/1, 4/1 Radionics Expanded |
||||||||||||||||
*47 Split/Dual Reporting (No Pagers!) | I_0_I | |||||||||||||||||
|
||||||||||||||||||
*48 15 Sec Burg Dial Delay | I_0_I |
0 = No 1 = Yes |
||||||||||||||||
*49 Periodic Test Message | I_3_I |
0 = None 1 = 24 Hours 2 = Weekly 3 = Monthly |
||||||||||||||||
*50 Sescoa/Radionics | I_0_I |
0 = No 1 = Yes |
||||||||||||||||
*51 Confirmation of Arming Ding | I_0_I |
0 = No 1 = Yes 2 = Yes for RF Arming) |
||||||||||||||||
(6139 Alpha keypad is required for programming Zones) | ||||||||||||||||||
*56 Zone Assignments | (Max 30 wireless zones in addition to the 2 onboard zones) | |||||||||||||||||
|
||||||||||||||||||
1. “Enter Zn No.” enter zone to program then press * or 00 to quit | ||||||||||||||||||
2. Keypad will show summary of zones programming, press * | ||||||||||||||||||
3. “Zone Type?” enter type then * |
00 = Zone Disabled/Deleted 01 = Delay Zone 02 = Do not Use 03 = Perimeter/Instant 04 = Interior Follower/Motions 05 = Trouble by Day/Alarm by Night 06 = 24 hour Silent/Holdup 07 = 24 hour Police Panic 08 = 24 hour Aux/Medical 09 = Fire 10 = Interior Delay 20 = Arm-Stay (RF only) 21 = Arm-Away (RF only) 22 = Disarm (RF only) 23 = No Alarm Response |
|||||||||||||||||
4. “Report Code?” enter 10 then * | ||||||||||||||||||
5. “Input Device?” enter device then * |
1 for Hardwired 2 for Auxiliary Wired (with 4219/4229 Expander) 3 for Supervised RF (most sensors are RF) 4 for Un-Supervised RF 5 RF Button Type (Keyfobs/Panics etc) |
|||||||||||||||||
6. Cursor should flash above “LP#”, Enter Loop number 1 to 4 depending on sensor | ||||||||||||||||||
Door Switch |
– Loop 1 = External Sensor Connector – Loop 2 = Internal Reed Switch |
|||||||||||||||||
Glassbreak | – Loop 1 | |||||||||||||||||
Smoke Detectors | – Loop 1 | |||||||||||||||||
Motions | – Loop 1 | |||||||||||||||||
Keyfobs |
– Loop 1 = Bottom Right Button (Each button counts as 1 zone) – Loop 2 = Top Right Button – Loop 3 = Top Left Button – Loop 4 = Bottom Left Button |
|||||||||||||||||
7. “Learn Sensor Y/N?” press 1 and trip sensor twice, you cannot manually enter serial number | ||||||||||||||||||
8. “Alpha Program?” press 0 if not programming Alpha descriptions | ||||||||||||||||||
9. ” Keypad shows new summary of programming or be back to “Enter zone number” | ||||||||||||||||||
10. If finished programming zones enter 00 at “Enter zone no” to return to normal programming | ||||||||||||||||||
*60 Trouble Report Code | I_1_I_0_I | |||||||||||||||||
*61 Bypass Report Code | I_0_I_0_I | |||||||||||||||||
*62 AC Loss Report Code | I_1_I_0_I | |||||||||||||||||
*63 Low Bat Report Code | I_1_I_0_I | |||||||||||||||||
*64 Test Report Code | I_0_I_0_I | |||||||||||||||||
*65 Open (Disarm)/Exit Alarm |
I_0_I_0_I Opening Report I_0_I_0_I Exit Alarm |
|||||||||||||||||
*66 Away/Stay Close | I_0_I_0_I | |||||||||||||||||
*67 RF Xmtr Low Bat | I_0_I_0_I | |||||||||||||||||
*68 Cancel Report Code | I_1_I_0_I | |||||||||||||||||
*69 Group Restores for Trouble |
I_0_I RF Low Bat, Bypass |
|||||||||||||||||
*70 Alarm Restore Code | I_0_I | |||||||||||||||||
*71 Trouble Restore Code | I_0_I_0_I | |||||||||||||||||
*72 Bypass Restore Code | I_0_I_0_I | |||||||||||||||||
*73 AC Restore Code | I_0_I_0_I | |||||||||||||||||
*74 Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||
*75 RF Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||
*80 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||||||||||||||||
*81 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||||||||||||||||
*82 Custom Alpha Editing (Leave Alone) | ||||||||||||||||||
*83 Add/Delete 5800 RF Input IDs (Alternate way of programming sensors, not normally used) | ||||||||||||||||||
*92 Reports per Armed Period | I_0_I |
0 = 10 per armed period 1 = Unlimited per Armed period |
||||||||||||||||
*94 Download Phone Number | I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I_ _I | |||||||||||||||||
*95 Ring Count | I_# 15_I | 0 to #15 #15 Enables Downloading | ||||||||||||||||
*96 Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s) | ||||||||||||||||||
*97 Default Panel (No Value needed, keypad will beep and default panel) | ||||||||||||||||||
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) | ||||||||||||||||||
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) |