Zones | 32 Total, 8 Hardwired (1 to 8), 24 Wireless (10 to 33) | ||
Resistors | 2k | ||
Wireless | Yes | ||
Batteries | 12 volt Rechargable inside main Panel, AC Transformer 16 volts | ||
|
|||
Downloadable | No, We do not have the available software | ||
Partitions | 2 | ||
Panic Buttons |
Police Panic – * and # Fire Panic – 1 and * Medical Panic – 3 and # |
||
Status | Press * if keypad shows NOT READY to view open zones | ||
Arm Away | 4-digit code + 2 (AWAY) to arm everything | ||
Arm Stay | 4-digit code + 3 (STAY) to arm all but motions | ||
Instant Arm | 4-digit code + 7 (INSTANT), this also bypasses motions | ||
Max Arming | 4-digit code + 4 (MAX) and everything arms instant | ||
Disarm | 4 digit code + 1 (OFF) | ||
Silence Alarm |
4-digit code + 1 (OFF) twice to turn off siren and reset display (If code is entered wrong, wait 2 or 3 seconds then try again) |
||
Bypass |
4-digit code + 6 (BYPASS) + zone (01, 02 03 etc) (keypad will beep, BYPASS + Zone should show, arm system) |
||
Alarm Memory | There is no alarm memory | ||
Reset Smoke |
4-digit code + 1 (OFF) twice to turn off siren and reset smoke (If this does NOT reset smoke detector set for service, smoke is bad) |
||
Door Chimes | 4-digit code + 9 (CHIME) | ||
Quick-Arm | # + 2 for AWAY, # + 3 for STAY | ||
Go/NoGo test |
(Verify signal strength) 1. Installer code # 4 2. Receiver gain is reduced by 50% 3. Keypad will beep 3 times to indicate signal reception 4. Enter 4-digit Code + 1 (OFF) |
||
Test Mode |
4-Digit Code + 5 (TEST) Keypad will beep every 3 minutes Open sensors and keypad will sound End test with 4-digit Code + OFF key |
||
Pager Signals |
Alarm sends Account + 911 + 3 digit Zone Open sends Account + 001 + 3 digit User Close sends Account + 002 + 3 digit User Trouble sends Account + 811 + 3 digit Zone |