Enter Program Master Code + 8 + 0 (Display should show 20)
or Power down then back up and press * and # within 1 minute
(If exiting programming you can re-enter within 1 minute by pressing * and #)
Move to Location * + Location
View Location # + Location (Display will read off one digit at a time)
Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 0
Default panel CLICK HERE
Note: The format on this panel cannot be changed from CID. There is no location *46

*20 Installer Code I_6_I_3_I_2_I_1_I
*21 Quick Arm Enable I_1_I 0 = No
1 = Yes
*22 RF (Wireless) System Type I_?_I 0 = None
1 = 5800 wireless with 5881 receiver
4 = 5800 wireless with 5881 RF Jamming
*23 Force Bypass Enable I_0_I 0 = No
1 = Yes
*24 RF House Code I_0_I_0_I 00 = Disabled / 01-31
Used only with 5700 series wireless
5804BD keyfob and 5827BD Keypad
(House Code must match sensors)

*25 Output Relay Module I_0_I 0 = None
3 = 4204 Relay Module
*26 4284/4285 Voice Module Code
(Allows access to Voice module)
I_0_I_0_I 00 = Disabled
1st digit = 1 to 9
2nd digit = # + 11 = * or # + 12 = #
*27 Output to Long Range Radio I_0_I 0 = No
1 = Yes
*28 Single Alarm Sound/Zone I_0_I 0 = No
1 = Yes
*29 Fire Sounder Timeout I_1_I 0 = Yes
1 = No Fire Timeout
*30 Alarm Bell Timeout I_2_I 0 = None
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
4 = 16 minutes
*36 Exit Delay I_6_I_0_I 0 – 99 seconds
*37 Entry Delay 1 I_3_I_0_I 0 – 99 seconds
*38 Entry Delay 2 I_3_I_0_I 0 – 99 seconds
*39 Audible Exit Warning I_1_I 0 = No
1 = Yes
*40 PABX Access Code I__I__I__I__I__I__I (If 9 is needed to dial add here)
*41 Primary Phone (12 digits) I__I__I__I__I__I__I__I__I__I__I__I__I
End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause
*42 Secondary Phone I__I__I__I__I__I__I__I__I__I__I__I__I
Pager on this panel is location *90
*43 Subscriber Account I__I__I__I__I
Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15
*45 Phone Sys Select I_1_I 0 = Pulse Dial
1 = DTMF Dial
2 = Pulse Dial, CS on Watts Line
3 = DTMF Dial, CS on Watts Line
*47 Split/Dual Reporting I_0_I (use 6 for pagers)
To Primary Phone -To Secondary Phone
0 = All Reports -Backup only
1 = Alarms, Restore, Cancel -All Other Reports
2 = All Reports except Open/Close, Test -Open/Close, Test
3 = Alarms, Restore, Cancel -All Reports
4 = All Reports except Open/Close, Test -All Reports
5 = All Reports (Dual Reporting) -All Reports
6 = All reports except Open/Close -Alarms, Open/Close, Troubles
7 = All reports -Alarms, Troubles
8 = All reports -Alarms, Open/Close, Troubles
9 = All reports except Open/Close -Alarms, Open/Close for Users 5-25, Troubles
*48 15 Sec Burg Dial Delay I_0_I 0 = No
1 = Yes
*49 Periodic Test Message I_3_I 0 = None
1 = 24 Hours
2 = Weekly
3 = Monthly
*51 Confirmation of Arming Ding I_0_I 0 = No
1 = Yes
2 = Yes for RF Arming (keyfobs etc)
*52 Zone 3 Response I_0_I 0 = 400 ms
1 = 10 ms
*53 Zone 25 Response I_0_I 0 = 15 seconds
1 = 1 Minute
2 = 2 Minutes
3 = 3 Minutes (etc)
Must use 6139 Alpha Keypad here
*56 Zone Assignments (Max 16 hardwired and/or wireless zones in addition to the 8 onboard zones)
Hardwire Zones 01 to 06
4219/4229 Zone Expander Zones 10 to 17 (depends on receiver capacity)
Police Panic Zone 07
Duress Zone 08
Receiver Tamper/Trouble Zone 09
Wireless Zones 10 to 30
Fire Panic Zone 95
Medical Panic Zone 96
1. At “Program Tool?” press 0, if “Set to Confirm?” shows press 1
2. “Enter Zn No.” enter zone to program then press *
3. Keypad will show summary of zones programming, press *
4. “Zone Type?” enter type then * 00 = Zone Disabled/Deleted
01 = Delay Zone
02 = Do not Use
03 = Perimeter/Instant
04 = Interior Follower/Motions
05 = Trouble by Day/Alarm by Night
06 = 24 hour Silent/Holdup
07 = 24 hour Police Panic
08 = 24 hour Aux/Medical
09 = Fire
10 = Interior Delay
20 = Arm-Stay (RF only)
21 = Arm-Away (RF only)
22 = Disarm (RF only)
23 = No Alarm Response
25 = Oil Tank Monitor
5. “Report Code?” enter 10 then *
6. “Input Device?” enter device then * 1 for Hardwired
2 Not Used
3 for Supervised RF (most sensors are RF)
4 for Un-Supervised RF
5 RF Button Type (Keyfobs/Panics etc)
(New versions may skip step 7 and move to step 8, learn Loop number after learning sensor)
7. Cursor should flash above “LP#”, Enter Loop number
Door Switch – Internal switch loop 2,
– external connector loop 1
Glassbreak – Loop 1
Smoke Detectors – Loop 1
Motions – Loop 1
Keyfobs – Bottom Right Button = Loop 1
– Top Right Button = Loop 2 (Each button counts as 1 zone)
– Top Left Button = Loop 3
– Bottom Left Button = Loop 4
8. at “Serial Prog?” or “Learn S/N” press 1 and either enter serial number or trip sensor twice
Note: Serial numbers found on sticker on of sensor, if not, learn by tripping sensor
9. “Alpha Program?” press 0 if not programming Alpha descriptions
10. ” Keypad shows new summary of programming or be back to “Enter zone number”
11. If finished programming zones enter 00 at “Enter zone no” to return to normal programming
*60 Trouble Report Code I_1_I_0_I
*61 Bypass Report Code I_0_I_0_I
*62 AC Loss Report Code I_0_I_0_I
*63 Low Bat Report Code I_0_I_0_I
*64 Test Report Code I_1_I_0_I
*65 Open (Disarm)/Exit Alarm I_0_I_0_I 1st digit = Opening Report
2nd digit = Exit Alarm
*66 Away/Stay Report I_0_I Away
I_0_I Stay
*67 RF Xmtr Low Bat I_0_I_0_I
*68 Cancel Report Code I_1_I_0_I
*69 Group Restore Tble/RF/Bypass I_0_I
*70 Alarm Restore Code I_0_I (Required if smoke on system)
*71 Trouble Restore Code I_0_I_0_I
*72 Bypass Restore Code I_0_I_0_I
*73 AC Restore Code I_0_I_0_I
*74 Low Bat Rest Code I_0_I_0_I
*75 RF Low Bat Rest Code I_0_I_0_I
*80 Output Relays (Usually program only if 4204 Relay is enabled in *25)
*81 Output Relays (Usually program only if 4204 Relay is enabled in *25)
*82 Custom Alpha Editing (Do not Program)
*83 Sequential Mode (Alternate way of programming sensors, not used)
*90 Pager Custom Data I__I__I__I__I__I__I__I__I__I__I__I__I
End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause
*91 Option Selection I_0_I 0 = None
4 = AAV 2-way module enable
8 = Exit Delay Restart
(4 turns off siren sounds during 2-way)
*92 Reports per Armed Period I_0_I 0 = 10 per armed period
1 = Unlimited per Armed period
*94 Download Phone Number I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I__I
*95 Ring Count I_# 15_I (0 to #15 #15 = Answer Machine)
*96 Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s)
*97 Default Panel (No Value needed, keypad will beep and default panel)
Note: (This will lock out this panel and set back to ADT defaults)
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0)
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0)