This is a version of the Vista-20p 4-Wire Smoke Device Address Table Scheduling Info (Test Timer) |
||||||||||||||||||||||
|
||||||||||||||||||||||
|
||||||||||||||||||||||
*20 Installer Code | I_6_I_3_I_2_I_1_I | |||||||||||||||||||||
*21 Quick Arm Enable | I_1_I |
0 = No 1 = Yes |
||||||||||||||||||||
*22 RF Jam Option | I_0_I |
0 = None 1 = send RF Jam report |
||||||||||||||||||||
*23 Forced Bypass Enable | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||
*24 RF House Code |
I_0_I_0_I Part 1 I_0_I_0_I Part 2 I_0_I_0_I Common |
00 = Disabled | ||||||||||||||||||||
*26 Chime by Zone (Zone list 3) | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||
*27 X-10 House Code | I_0_I |
|
||||||||||||||||||||
*28 4285/4286 Voice Module Access Code (Allows access to Voice module) |
I_0_I_0_I |
00 = Disabled 1st digit = 1 to 9 2nd digit = # + 11 for * or # + 12 for # |
||||||||||||||||||||
*29 Output to Long Range Radio | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||
*31 Single Alarm Sounding/Zone | I_0_I | 0 = No (If 0, this will follow the swinger suppression field, *93) | ||||||||||||||||||||
1 = Yes | ||||||||||||||||||||||
*32 Fire Sounder Timeout | I_1_I |
0 = Timeout 1 = No Timeout |
||||||||||||||||||||
*33 Alarm Bell Timeout | I_2_I |
0 = None 1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
||||||||||||||||||||
*34 Exit Delay |
I_6_I_0_I part 1 I_6_I_0_I part 2 |
45 – 96 = 45 – 96 Seconds 97 = 120 Seconds |
||||||||||||||||||||
*35 Entry Delay #1 (Zone type 01) |
I_3_I_0_I part 1 I_3_I_0_I part 2 |
00 – 96 = 0 – 96 Seconds 97 = 120 Seconds 98 = 180 Seconds 99 = 240 Seconds |
||||||||||||||||||||
*36 Entry Delay #2 (Zone type 02) |
I_6_I_0_I part 1 I_6_I_0_I part 2 |
|||||||||||||||||||||
*37 Audible Exit Warning | I_1_I |
0=No 1=Yes |
||||||||||||||||||||
*38 Confirmation of Arming Ding | I_1_I |
0 = No 1 = Yes 2 = RF Only |
||||||||||||||||||||
*39 Power Up in Previous State | I_0_I |
0 = No 1 = Yes |
||||||||||||||||||||
*40 PABX Access Code (Up to 6 digits) | I__I__I__I__I__I__I (If 9 is needed to dial add here) | |||||||||||||||||||||
*41 Primary Phone (Up to 20 digits) |
I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I End Phone with * # + 11 = *# + 12 = # # + 13 = 2 second pause |
|||||||||||||||||||||
*42 Secondary Phone (Up to 20 digits) |
I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I End Phone with * # + 11 = *# + 12 = # # + 13 = 2 second pause |
|||||||||||||||||||||
*43 Partition 1 Primary Account Number |
I__I__I__I__I (Last 4 of Account) A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 |
|||||||||||||||||||||
*45 Partition 2 Primary Account Number |
I__I__I__I__I (Last 4 of Account) A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 |
|||||||||||||||||||||
*47 Phone System Select | I_3_I |
0 = Pulse Dial 1 = DTMF Dial 2 = Pulse Dial, CS on Watts Line 3 = DTMF Dial, CS on Watts Line |
||||||||||||||||||||
*48 Report Format |
I_7_I Primary I_7_I Secondary |
5 = 10 Digit Contact ID 7 = 4 Digit Contact ID E = 4 Digit Contact ID w/shutdown F = 10 Digit Contact ID w/shutdown |
||||||||||||||||||||
*49 Split/Dual Reporting | I_0_I | |||||||||||||||||||||
|
||||||||||||||||||||||
*50 Burg Dialer Delay | I_0_I |
0 = No delay 1 = 15 second delay |
||||||||||||||||||||
*53 Misc Fault Delay Time | I_0_I |
|
||||||||||||||||||||
*54 Dynamic Signaling Delay | I_0_I |
0 = No delay (Both signals sent) 1 = 15 seconds 2 = 30 seconds (etc) |
||||||||||||||||||||
*55 Dynamic Signaling Priority | I_0_I |
0 = Primary Dialer First (Alarmnet is secondary) 1 = Long Range Radio First (Alarmnet is primary) |
||||||||||||||||||||
*56 Zone Assignments | ||||||||||||||||||||||
Hardwired Zones 01 to 06 (2-Wire Smokes Zone 1 only, 4-Wire can be 2 to 6) 4219/4229 Hardwire Expander Zones 09 to 16; Zones 17 to 24; Zones 25 to 32; Zones 33 to 40; Zones 41 to 48 Wireless Zones 09 to 34 (Depending on capacity of 5881 receiver) Keyfob Zones Zones 49 to 56 Duress Zone 92 Fire Panic Zone 95 Medical Panic Zone 96 Police Panic Zone 99 |
||||||||||||||||||||||
1. Keypad displays “Zone Prog?” press 1 | ||||||||||||||||||||||
2. “Enter Zn No.” enter which zone to program (01-56, 89-91, 95, 96, 97, 99) press * | ||||||||||||||||||||||
3. Keypad will show summary zones programming, press * | ||||||||||||||||||||||
4. “Zone Type?” enter type then * |
00 = Zone Disabled/Deleted 01 = Delay Zone 02 = Secondary Delay Zone 03 = Perimeter/Instant 04 = Interior Follower/Motions 05 = Trouble by Day/Alarm by Night 06 = 24 hour Silent/Holdup 07 = 24 hour Police Panic 08 = 24 hour Aux/Medical 09 = Fire 10 = Interior Delay 12 = Monitor Zone 14 = Carbon Monoxide 16 = Fire w/Verification 20 = Arm-Stay (RF only) 21 = Arm-Away (RF only) 22 = Disarm (RF only) 23 = No Alarm Response 24 = Silent Burglary 25 = 24 Hour Non-Alarm 77 = Keyswitch 90 = Configurable Zone Type 1 * See section *182 91 = Configurable Zone Type 2 * See section * 184 |
|||||||||||||||||||||
6. “Partition” 1 – 3 | ||||||||||||||||||||||
7. “Report Code?” enter 10 then * | ||||||||||||||||||||||
8. “Input Device?” enter device then * |
1 = for Hardwired 2 = Auxiliary Wired (with 4219/4229 Expander) 3 = for Supervised RF (most sensors are RF) 4 = for Un-Supervised RF 5 = RF Button Type (Keyfobs/Panics etc) |
|||||||||||||||||||||
9. Cursor should flash above the loop number “LP#”, Enter 1 to 4 depending on sensor | ||||||||||||||||||||||
|
||||||||||||||||||||||
10. “Learn Sensor Y/N?” press 1 and trip sensor twice (you cannot enter serial numbers) | ||||||||||||||||||||||
11. “Alpha Program?” press 0 if not programming Alpha descriptions | ||||||||||||||||||||||
12. ” Keypad will show either new summary for zone or “Enter zone number” | ||||||||||||||||||||||
13. If finished programming enter 00 at “Enter zone no” to return to normal programming | ||||||||||||||||||||||
*57 Click to show details >> Function Key Programming | ||||||||||||||||||||||
*58 Expert Mode (Not usually used for zone programming) | ||||||||||||||||||||||
*59 Exit Error Report Code | I_1_I |
0 = No report 1 = Will report |
||||||||||||||||||||
*60 Trouble Report Code | I_1_I_0_I | |||||||||||||||||||||
*61 Bypass Report Code | I_0_I_0_I | |||||||||||||||||||||
*62 AC Loss Report Code | I_1_I_0_I | |||||||||||||||||||||
*63 Low Bat Report Code | I_1_I_0_I | |||||||||||||||||||||
*64 Test Report Code | I_0_I_0_I | |||||||||||||||||||||
*65 Open Report Code | I_0_I I_0_I I_0_I |
Part 1 Part 2 Common |
||||||||||||||||||||
*66 Away/Stay Report | I_0_I_0_I I_0_I_0_I I_0_I_0_I |
Partition 1 Partition 2 Common |
||||||||||||||||||||
*67 RF Xmtr Low Bat | I_0_I_0_I | |||||||||||||||||||||
*68 Cancel Report Code | I_1_I_0_I | |||||||||||||||||||||
*70 Alarm Restore Code | I_0_I | (Must be enabled if using smoke) | ||||||||||||||||||||
*71 Trouble Restore Code | I_0_I_0_I | |||||||||||||||||||||
*72 Bypass Restore Code | I_0_I_0_I | |||||||||||||||||||||
*73 AC Restore Code | I_0_I_0_I | |||||||||||||||||||||
*74 Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||||||
*75 RF Low Bat Rest Code | I_0_I_0_I | |||||||||||||||||||||
*76 Test Restore Rpt Code | I_0_I_0_I | |||||||||||||||||||||
*77 Daylight Sav Time Start/End Month | I_3_I_11_I |
0 = Disabled 1 – 9 = January – September (1 = Jan, 2 = Feb, etc) #10 = October, #11 = November, #12 = December |
||||||||||||||||||||
*78 Daylight Sav Time Start/End Wknd | I_2_I_1_I |
0 = Disabled 1 = First 2 = Second 3 = Third 4 = Fourth 5 = Last 6 = Next to last 7 = Third to last |
||||||||||||||||||||
*79 Output Device Mapping | ||||||||||||||||||||||
*80 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||||||||||||||||||||
*81 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||||||||||||||||||||
*82 Custom Alpha Editing (Do not Program) | ||||||||||||||||||||||
*84 Auto Stay Arm | I_0_I | 0 = Disabled; 1 = Part 1 only, 2 = Part 2 only, 3 = both |
||||||||||||||||||||
*85 Cross Zone Timer | I_0_I |
|
||||||||||||||||||||
*86 Cancel Verify Keypad Display | I_0_I |
0 = No “alarm cancelled” display 1 = Displays “alarm cancelled” when code + off is pressed |
||||||||||||||||||||
*89 Event Log 80% Full | I_0_I | |||||||||||||||||||||
*90 Event Logging | I_15_I |
0 = None 1 = Alarm/Restore 2 = Trouble/Restore 4 = Bypass/Bypass Restore 8 = Open/Close |
||||||||||||||||||||
*91 Option Selection | I_0_I Options I_0_ICall Waiting Disable |
0 = None 1 = Bell Supervision Processing (Must also cut jumper) 4 = AAV 8 = Exit Delay Restart |
||||||||||||||||||||
*92 Phone Monitor Enable | I_0_I Timeout |
0 = Disabled 1 – 15 = 1 to 15 minutes |
||||||||||||||||||||
I_0_I Display (Panel MUST be properly grounded for this to work!) 0 = Not Used 1 = KP Disp 2 = KP Disp/Sounder 3 = KP Disp/Sounder/Dev 2 starts |
||||||||||||||||||||||
*93 Reports per Armed Period | I_0_I |
0 = 10 per Armed period 1 = Unlimited per Armed period |
||||||||||||||||||||
*94 Download Phone Number | I_1_I_8_I_0_I_0_I_5_I_6_I_0_I_2_I_0_I_0_I_1_I__I | |||||||||||||||||||||
*95 Ring Count | I_#15_I | 0 to #15 #15 = Answer Machine Defeat | ||||||||||||||||||||
*96 Reinitialize Download (No Value needed, keypad will just beep) | ||||||||||||||||||||||
*97 Default Panel (No Value needed, keypad will beep and default panel) (Some fields will be defaulted and cannot be accessed without download. We cannot download ADT panels. So don’t default this panel) |
||||||||||||||||||||||
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) | ||||||||||||||||||||||
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) | ||||||||||||||||||||||
*160 Pager 1 Phone No. |
I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I (Enter up to 20 digits. 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
|||||||||||||||||||||
*161 Pager 1 Characters |
I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I (Enter the optional additional prefix characters up to 16 digits 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
|||||||||||||||||||||
*162 Pager 1 Reporting Options |
P1 I_0_I P2 I_0_I Com I_0_I |
Select from the following options: 0 = No reports sent 1 = Open/closes all users 4 = All alarms and troubles 5 = All alarms / troubles, and open/closes for all users 12 = Alarms / troubles for zones entered in zone list 9 13 = Alarms / troubles for zones entered in zone list 9, and open/closes for all users |
||||||||||||||||||||
*163 Pager 2 Phone No. |
I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I (Enter up to 20 digits. 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
|||||||||||||||||||||
*164 Pager 2 Characters |
I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I (Enter the optional additional prefix characters up to 16 digits 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
|||||||||||||||||||||
*165 Pager 2 Reporting Options |
P1 I_0_I P2 I_0_I Com I_0_I |
Select from the following options: 0 = No reports sent 1 = Open/closes all users 4 = All alarms and troubles 5 = All alarms / troubles, and open/closes for all users 12 = Alarms / troubles for zones entered in zone list 9 13 = Alarms / troubles for zones entered in zone list 9, and open/closes for all users |
||||||||||||||||||||
*166 Pager 3 Phone No. |
I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I (Enter up to 20 digits. 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
|||||||||||||||||||||
*167 Pager 3 Characters |
I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I (Enter the optional additional prefix characters up to 16 digits 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
|||||||||||||||||||||
*168 Pager 3 Reporting Options |
P1 I_0_I P2 I_0_I Com I_0_I |
Select from the following options: 0 = No reports sent 1 = Open/closes all users 4 = All alarms and troubles 5 = All alarms / troubles, and open/closes for all users 12 = Alarms / troubles for zones entered in zone list 9 13 = Alarms / troubles for zones entered in zone list 9, and open/closes for all users |
||||||||||||||||||||
*169 Pager 4 Phone No. |
I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I (Enter up to 20 digits. 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
|||||||||||||||||||||
*170 Pager 4 Characters |
I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I__I (Enter the optional additional prefix characters up to 16 digits 0-9; # + 11 = ‘*’; # + 12 = ‘#’; # + 13 = 2 second pause) |
|||||||||||||||||||||
*171 Pager 4 Reporting Options < |
P1 I_0_I P2 I_0_I Com I_0_I |
Select from the following options: 0 = No reports sent 1 = Open/closes all users 4 = All alarms and troubles 5 = All alarms / troubles, and open/closes for all users 12 = Alarms / troubles for zones entered in zone list 9 13 = Alarms / troubles for zones entered in zone list 9, and open/closes for all users |
||||||||||||||||||||
*172 Pager Delay Option For Alarms This delay is for ALL pagers in the system. |
I_0_I | 0 = none, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes |
||||||||||||||||||||
NOTE: The delay does not reset for new alarms occurring while an existing pager delay is in progress. | ||||||||||||||||||||||
*173 RF Reporting Options | I_0_I |
1 = RF Tamper Reports while disarmed (1 = enable 0 = disable) 2 = RF button types send low battery reports (1 = enable 0 = disable) 8 = RF low battery reports delayed (1 = 28 day delay 0 = immediate) |
||||||||||||||||||||
*174 Clean Me Reporting Option | I_0_I | 0 = disable; 1 = Clean Me signal reports; 2 = Delayed for 28 days |
||||||||||||||||||||
(For ESL smoke detectors) Note: If Clean Me is enabled, you must enter “3” in field *56 programming for zone 1 response time. |
||||||||||||||||||||||
*175 Up And About Time | I_0_I |
0 = None 1 – 15 = 1 to 15 hours |
||||||||||||||||||||
(This feature requires programming using the Up and About schedule. If no zones are faulted- -or no key is pressed within selected time period, signal is sent to central station) | ||||||||||||||||||||||
*176 Lack Of Use Option | I_0_I | 1-15 weeks | ||||||||||||||||||||
(If panel is not armed within seleted time period, signal is sent to central station) | ||||||||||||||||||||||
*177 Device Duration 1, 2 (Used in *80 Menu mode device action 5/6) |
I_0_I I_0_I |
|
||||||||||||||||||||
*180 Single Zone Bypass | I_0_I |
0 = Disable 1 = Enable |
||||||||||||||||||||
*181 50/60 Hertz AC Operation | I_0_I | 0 = 60 Hz; 1 = 50 Hz |
||||||||||||||||||||
*182 Configurable Zone Type 90 |
|
|||||||||||||||||||||
Enter the appropriate Value for each entry, 1-10, based on the links. Each entry is the sum of the values on its selected options. (0-9; # + 10 = 10, # = 11 = 11, # + 12 = 12, # + 13 = 13, # + 14 = 14, # + 15 = 15) |
||||||||||||||||||||||
*183 Zone Type 90 Report Codes (IMPORTANT: Use Existing CID Codes, if appropriate, or define Unique codes in CID code range 750-789.) |
90 ALARM ID: XXX TROUBLE ID: XXX |
Enter the desired 3 digit CID report codes for alarms and troubles occurring on zones assigned to this zone type. Enter the codes sequentially (all 6 digits). When entering digits, [#] moves cursor back, [*] moves forward. Press [*] when done to continue. |
||||||||||||||||||||
*184 Configurable Zone Type 91 |
|
|||||||||||||||||||||
Enter the appropriate Value for each entry, 1-10, based on the links. Each entry is the sum of the values on its selected options. (0-9; # + 10 = 10, # = 11 = 11, # + 12 = 12, # + 13 = 13, # + 14 = 14, # + 15 = 15) |
||||||||||||||||||||||
*185 Zone Type 91 Report Codes (IMPORTANT: Use Existing CID Codes, if appropriate, or define Unique codes in CID code range 750-789.) |
91 ALARM ID: XXX TROUBLE ID: XXX |
Enter the desired 3 digit CID report codes for alarms and troubles occurring on zones assigned to this zone type. Enter the codes sequentially (all 6 digits). When entering digits, [#] moves cursor back, [*] moves forward. Press [*] when done to continue. |
||||||||||||||||||||
*190 Keypad 2 Device Address 17 | I_0_I I_0_I |
|
||||||||||||||||||||
*191 Keypad 3 Device Address 18 | I_0_I I_0_I | See field *190 for entries. | ||||||||||||||||||||
*192 Keypad 3 Device Address 19 | I_0_I I_0_I | See field *190 for entries. | ||||||||||||||||||||
*193 Keypad 3 Device Address 20 | I_0_I I_0_I | See field *190 for entries. | ||||||||||||||||||||
*194 Keypad 3 Device Address 21 | I_0_I I_0_I | See field *190 for entries. | ||||||||||||||||||||
*195 Keypad 3 Device Address 22 | I_0_I I_0_I | See field *190 for entries. | ||||||||||||||||||||
*196 Keypad 3 Device Address 23 | I_0_I I_0_I | See field *190 for entries. | ||||||||||||||||||||
*197 Exit Time Display Interval | I_0_I | 0 = No display; 1-5 = sec between display Refresh | ||||||||||||||||||||
*198 Display Partition Number | I_0_I |
For Alpha Displays Only 0 = No 1 = Yes (Partition # will display on Alpha Display) |
||||||||||||||||||||
*199 ECP Fail Display | I_0_I |
0 = 3-digit display (“1” + device address) 1 = 2-digit fixed display as “91” |