Master Code | User 02 |
Secondary Codes | User 03 to 48 |
Duress Code | User 49 (Duress can be any location, but preferred in location 49) |
|
|
Add Master | Installer Code + 8 +02 + New Master Code (Keypad should beep) |
Change Master | Master Code + 8 + 02 + New Master Code twice (Keypad should beep) |
Add Code | Master Code + 8 + User (03 to 49) + New Code (Keypad should beep) |
Erase Code | Master Code + 8 + User (03 to 49) + # + 0 (Keypad should beep) |
After above commands keypad should beep indicating successful, if not try again | |
You cannot pause more than 2 seconds while entering below commands or it won’t work | |
Assigning Attributes | Master code + 8 + User (03 to 49) + # + [Attribute Number] + [Value] |
Attributes Values | |
1 = Authority Level 0-4 (see Authority Level table above) 2 = Access Group 0-8 (0= not assigned to a group) 3 = Active Partition(s) 1, 2, 3 (common) Enter partitions consecutively if more than one and press [#] to end the entries 4 = RF Zone # 1st zone number of keyfob 5 = Open/Close paging 1 for yes, 0 for no |
|
Authority Levels (Can only be changed for users 03 – 32) | |
0 = Standard User 1 = Arm Only, Code can only arm system 2 = Guest Code, can only disarm system if it was used to arm system 3 = Duress ,Acts like standard user, but also silently sends a duress message to central station 4 = Partition Master, Can Program and delete codes only in the partition it is assigned to |