Ademco Safewatch 3000 Codes

Master Code User 02
Secondary Codes User 03 to 49
Duress Code User 49 (Duress can be any location, but preferred in location 49)

Add Master Installer Code + 8 +02 + New Master Code (Keypad should beep)
Change Master Master Code + 8 + 02 + New Master Code twice (Keypad should beep)
Add Code Master Code + 8 + User (03 to 49) + New Code (Keypad should beep)
Erase Code Master Code + 8 + User (03 to 49) + # + 0 (Keypad should beep)
After above commands keypad should beep indicating successful, if not try again
You cannot pause more than 2 seconds while entering below commands or it won’t work
Assigning Attributes Master code + 8 + User (03 to 49) + # + [Attribute Number] + [Value]
Attributes Values
1 = Authority Level 0-4 (see Authority Level table above)
2 = Access Group 0-8 (0= not assigned to a group)
3 = Active Partition(s) 1, 2, 3 (common) Enter partitions consecutively if more than one and press [#] to end
4 = RF Zone # 1st zone number of keyfob
5 = Open/Close paging 1 for yes, 0 for no
Authority Levels (Can only be changed for users 03 – 32)
Level Value Functions
0 – Standard User
1 – Arm Only – Code can only arm system
2 – Guest – Code can only disarm system if was used to arm system
3 – Duress – Performs security functions, but also silently sends a duress message to central station
4 – Partition Master – Can Program and delete codes only in the partition it is assigned to