Ademco Safewatch 3000 Basics

Batteries 12 volt rechargeable inside main panel, AC Transformer is 16 volts
Door/Windows 3-volt Lithium (Panasonic CR123A)
Motion Sensor 2 3-volt Lithium (Panasonic CR123A)
Smoke Detector 2 9-volt Alkaline
Remote Keypads 9 Volt Alkaline
Keyfobs 3-volt Lithium (CR2430 Hearing Aid type)
Remote Panics 3-volt Lithium (Panasonic CR123A)
Downloadable No, We do not have the available software
Panic Buttons Police Panic – * and #
Fire Panic – 1 and *
Medical Panic – 3 and #
Status Press * if keypad shows NOT READY to view open zones
Quick Bypass (if enabled) 4-digit code + 6, after 10 seconds, all open zones should show and bypass
Go to Partition 4-digit code + * + the partition # (1, 2, 3)
Multiple Partition Arming 4-digit code + 0 + Arming/Disarming command (1, 2, 3, 33, 7)
Arm AWAY 4-digit code + 2 (AWAY
Arm Stay 4-digit code + 3 (STAY)
Night-Stay 4-digit code + 3 + 3
Disarm 4 digit code + 1 (OFF)
Quick-Arm Press # + 2 for AWAY, # + 3 for STAY
Instant Arm 4 digit code + 7 (INSTANT)
Walk Test 4-digit code + 5 + 0
Dialer Test Installer code + 5 + 1
Silence Alarm 4-digit code + 1 (OFF) twice to turn off siren and reset display
(If code is entered wrong, stop, press the [*] key and try again)
Door Chimes 4-digit code + 9 (CHIME)
Bypass 4-digit code + 6 (BYPASS) + 2 digit zone # (01, 02 03 etc)
Alarm Memory There is no alarm memory
Reset Smoke 4-digit code + 1 (OFF) twice to turn off siren and reset smoke
(If this does NOT reset smoke detector set for service, smoke is bad)
Test Sensors 4-Digit Code + 5 (TEST)
Keypad will beep every 3 minutes
Open sensors and keypad will sound
End test with 4-digit Code + 1 (OFF) key
(Wireless motions require no movement for 4 minutes prior to testing)
Activate Relay 4-digit Code + # + 7
Deactivate Relay 4-digit Code + # + 8
Pager Signals Alarms Account + 911 + 4 digit Zone #
Openings Account + 101 + 4 digit User #
Closings Account + 102 + 4 digit User #
Trouble Account + 811 + 4 digit Zone #
View Time/Date: 4-digit code + # + 63
Change Time/Date: 4-digit code + # + 63 + *
Enter 2-digit Hour then *
Enter 2-digit Minutes then *
Enter 0 for AM; 1 for PM then *
Enter 2-digit Year then *
Enter 2-digit Month then *
Enter 2-digit Day then *
View Event Log 4-digit code + # + 60
Backwards: *
Forwards: #
Exit: Any key other than * or #