Ademco Safewatch 2000 Trouble

Check 9 Generic trouble display/expansion module failure
NO AC AC Power Failure
BAT Panel Battery Low
BAT xxx Wireless zone low battery where xxx is the zone number
Check 01 to 34 Zone is not communicating with panel
D1 System is in wait mode, system may have an internal problem
System Busy System is in wait mode, system may have an internal problem
CA Alarm was canceled, this is not a trouble
Canceled Alarm Alarm was canceled, this is not a trouble
CC Panel is being downloaded by Tech Support
Modem Comm Panel is being downloaded by Tech Support
94 Telephone Line Failure
70 Siren supervision failure
90 RF Jam detected
00 Bat Wireless keypad low battery
Cd Phone test okay
dO Dialer off
dd Walk test is active (Code + 5 + 0) to exit
dC Download complete
dF Download failed
Alarm xxx Zone is or was in alarm where xxx is the zone number
Fault xxx Zone is faulted where xxx is the zone number
Check xxx Zone is not communicating with the panel where xxx is the zone number
EA Exit Alarm, this is not a trouble, customer armed system
then left and didn’t close door before delay expired
FC Fail to Communicate
OC Open Circuit, bad keypad wire
Beep every
40 sec
System is in Test Mode (Press Code + 1 to exit)
Smoke Detector 4-digit Code + 1 (OFF) 4-digit Code + 1 (OFF) to turn off siren and reset Smoke Detector
(If this does not work power down system, Smoke Detector is bad)