Ademco 5140XM Program

Enter Program 1. 5140 + 8 + 0 + 0 (Display should show 00)
or
2.Power down then back up and press * and # within 1 minute
(If exiting programming you can re-enter within 1 minute by pressing * and #)
Move to Location * + Location
View Location # + Location (Display will read off one digit at a time)
Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00

*00 Installer Code I_5_I_1_I_4_I_0_I
*02 Zone Types for Zones 1 to 8
I_?_I_?_I Zone 1
I_?_I_?_I Zone 2
I_?_I_?_I Zone 3
I_?_I_?_I Zone 4
I_?_I_?_I Zone 5
I_?_I_?_I Zone 6
I_?_I_?_I Zone 7
I_?_I_?_I Zone 8
*03 Zone Types for Zones 9 to 16
I_?_I_?_I Zone 9
I_?_I_?_I Zone 10
I_?_I_?_I Zone 11
I_?_I_?_I Zone 12
I_?_I_?_I Zone 13
I_?_I_?_I Zone 14
I_?_I_?_I Zone 15
I_?_I_?_I Zone 16
00 = Disabled
01 = Entry/Exit 1
02 = Entry/Exit 2
03 = Instant
04 = Interior
05 = Day Zone
06 = Silent Holdup
07 = Audible Police
08 = 24 Hour Auxiliary
09 = Fire w/o Verification
10 = InteriorDelay
16 = Fire w/Verification
17 = Fire Water Flow
18 = Fire Supervisory
19 = 24 Hour Trouble
*04 Zone Type for Zone 17 to 24
I_?_I_?_I Zone 17
I_0_I_0_I Zone 18
I_0_I_0_I Zone 19
I_0_I_0_I Zone 20
I_0_I_0_I Zone 21
I_0_I_0_I Zone 22
I_0_I_0_I Zone 23
I_0_I_0_I Zone 24
*05 Zone Types for 25 to Panics
I_0_I_0_I Zone 25
I_0_I_0_I Zone 26
I_0_I_0_I Zone 27
I_0_I_0_I Not Used
I_0_I_0_I Zone 97 Polling LP
I_0_I_8_I Zone 95 1 & *
I_0_I_9_I Zone 96 3 & #
I_0_I_7_I Zone 99 * & #
*09 Entry Delay I_0_I_2_I 00 to 15 x15 seconds
*10 Exit Delay 1 I_0_I_4_I 00 to 15 x15 seconds
*11 Entry Delay 2 I_0_I_3_I 00 to 15 x15 seconds
*12 Exit Delay 2 I_0_I_4_I 00 to 15 x15 seconds
*13 Bell 1 Timeout I_0_I_8_I 00 to 15 x2 minutes
*15 Keyswitch Enable I_0_I 0 = No
1 = Arms/Disarms/Silences Alarms
2 = Silences only if Fire Alarm
*16 Bell 1 Confirmation of Arming Ding I_0_I 0 = Disable
1 = Enable
*17 AC Loss Keypad Sounding I_1_I 0 = No
1 = Yes
*18 Bell 1 AC Loss Alarm I_0_I 0 = No
1 = Yes
*19 AC Randomize I_2_I 0 = No
1 = Randomize 10 – 40 minutes
2 = Randomize 6 – 12 Hours
*23 Multiple Alarms I_1_I 0 = No
1 = Yes
*24 4190WH Tamper disable I_0_I 0 = No
1 = Yes
*25 Burglary Trigger for Zone Type 8 I_0_I 0 = No
1 = Yes
*26 Intelligent Test Reporting I_0_I 0 = No
1 = No Report if other Reports Sent
*27 Test Report Interval I_0_I_2_I_4_I 000 = Disabled
001 to 199 Hours
*28 Power up in Previous State I_1_I 0 = No
1 = Yes
*29 Quick Arm I_1_I 0 = No
1 = Yes
*30 Main Dialer TouchTone Dialing I_1_I 0 = No
1 = Yes
*31 PABX Access Code I__I__I I__I__I I__I__I I__I__I
*32 Primary Account Number I_0_I_?_I I_0_I_?_I I_0_I_?_I I_0_I_?_I (2 digit entries)
Hex B = 11, C = 12, D = 13, E = 14, F = 15
*33 Primary Phone Number (12 digits) I__I__I__I__I__I__I__I__I__I__I__I__I
End Phone with * # + 11 = *, # + 12 = #, # + 13 = 2.5 second pause
*34 Secondary Phone Number I__I__I__I__I__I__I__I__I__I__I__I__I
*35 Download Phone Number I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I
*36 CSID Number I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I
(15’s Default CSID to Factory)
*37 Download Commands Enable I_1_I Dialer Shutdown
I_1_I System Shutdown
I_0_I Not Used
I_1_I Remote Bypass
I_1_I Remote Disarm
I_1_I Remote Arm
I_1_I Upload Programming
I_1_I Download Programming

0 = No
1 = Yes
*38 Inhibit Bypass of One Zone I_0_I_0_I 00 = All zones bypassable
01 to 64 = Zone 01 to 64
*39 Open/Close Report for Installer I_0_I 0 = No
1 = Yes
*40 Open/Close Report for Keyswitch I_0_I 0 = No
1 = Yes
*41 Normally Closed Zones 3 to 8 I_0_I 0 = EOL Resistors
1 = Normally Closed
*42 Dial Tone Pause I_0_I 0 = 5 seconds
1 = 11 seconds
2 = 30 seconds
*43 Dial Tone Detection I_0_I 0 = Pause then Dial
1 = Wait for True Dial Tone
*44 Ring Detection Count I_1_I_5_I 15 = Answering Machine
*45 Primary Format I_1_I 0 = Ademco Lo
1 = Contact ID
2 = Ademco High Speed
3 = Ademco Express
*46 Low Speed Format (Primary) I_0_I 0 = Ademco Low Speed
1 = Sescoa/Radionics
*47 Secondary Format I_1_I 0 = Ademco Lo
1 = Contact ID
2 = Ademco High Speed
3 = Ademco Express
*48 Low Speed Format (Secondary) I_0_I 0 = Ademco Low Speed
1 = Sescoa/Radionics
*49 Checksum Verify I_0_I 0 = No
1 = Yes
*50 Sescoa Radionics Select I_0_I 0 = Radionics
1 = Sescoa
*51 Dual Reporting I_0_I 0 = No
1 = Yes
*52 Standard/Expanded Report
for Primary
I_0_I Alarm/Fire Supv
I_0_I Restore
I_0_I Bypass
I_0_I Trouble
I_0_I Open/Close
I_0_I Low Bat/Walk Test
0 = Standard
1 = Expanded
*53 Standard/Expanded Report I_0_I Alarm/Fire Supv
for Secondary I_0_I Restore
I_0_I Bypass
I_0_I Trouble
I_0_I Open/Close
I_0_I Low Bat/Walk Test
0 = Standard
1 = Expanded
*54 Report Codes for Zones 1 to 8
I_0_I_1_I Zone 1
I_0_I_2_I Zone 2
I_0_I_3_I Zone 3
I_0_I_4_I Zone 4
I_0_I_5_I Zone 5
I_0_I_6_I Zone 6
I_0_I_7_I Zone 7
I_0_I_8_I Zone 8
*55 Report ID for Zones 1 to 8
I_0_I_1_I Zone 1
I_0_I_2_I Zone 2
I_0_I_3_I Zone 3
I_0_I_4_I Zone 4
I_0_I_5_I Zone 5
I_0_I_6_I Zone 6
I_0_I_7_I Zone 7
I_0_I_8_I Zone 8
*56 Report Codes for Zones 9 to 16
I_0_I_1_I Zone 9
I_0_I_2_I Zone 10
I_0_I_3_I Zone 11
I_0_I_4_I Zone 12
I_0_I_5_I Zone 13
I_0_I_6_I Zone 14
I_0_I_7_I Zone 15
I_0_I_8_I Zone 16
*57 Report ID for Zones 9 to 16
I_0_I_1_I Zone 9
I_0_I_2_I Zone 10
I_0_I_3_I Zone 11
I_0_I_4_I Zone 12
I_0_I_5_I Zone 13
I_0_I_6_I Zone 14
I_0_I_7_I Zone 15
I_0_I_8_I Zone 16
*58 Misc Alarms/Restorals for Zones 1 to 16
I_0_I_1_I Alarm/Supervision Restore
I_0_I_1_I Trouble
I_0_I_1_I Trouble Restore
I_0_I_0_I Bypass
I_0_I_0_I Bypass Restore
*59 Report Codes for Zones 17 to 24
I_0_I_1_I Zone 17
I_0_I_2_I Zone 18
I_0_I_3_I Zone 19
I_0_I_4_I Zone 20
I_0_I_5_I Zone 21
I_0_I_6_I Zone 22
I_0_I_7_I Zone 23
I_0_I_8_I Zone 24
*60 Report ID for Zones 17 to 24
I_0_I_1_I Zone 17
I_0_I_2_I Zone 18
I_0_I_3_I Zone 19
I_0_I_4_I Zone 20
I_0_I_5_I Zone 21
I_0_I_6_I Zone 22
I_0_I_7_I Zone 23
I_0_I_8_I Zone 24
*61 Report Codes for Zones 25 to 32
I_0_I_1_I Zone 25
I_0_I_2_I Zone 26
I_0_I_3_I Zone 27
I_0_I_4_I Zone 28
I_0_I_5_I Zone 29
I_0_I_6_I Zone 30
I_0_I_7_I Zone 31
I_0_I_8_I Zone 32
*62 Report ID for Zones 25 to 32
I_0_I_1_I Zone 25
I_0_I_2_I Zone 26
I_0_I_3_I Zone 27
I_0_I_4_I Zone 28
I_0_I_5_I Zone 29
I_0_I_6_I Zone 30
I_0_I_7_I Zone 31
I_0_I_8_I Zone 32
*63 Misc Alarms/Restorals for Zones 17 to 32
I_0_I_1_I Alarm/Supervision Restore
I_0_I_1_I Trouble
I_0_I_1_I Trouble Restore
I_0_I_0_I Bypass
I_0_I_0_I Bypass Restore
*64 Report Codes for Zones 33 to 40
I_0_I_1_I Zone 33
I_0_I_2_I Zone 34
I_0_I_3_I Zone 35
I_0_I_4_I Zone 36
I_0_I_5_I Zone 37
I_0_I_6_I Zone 38
I_0_I_7_I Zone 39
I_0_I_8_I Zone 40
*65 Report ID for Zones 33 to 40
I_0_I_1_I Zone 33
I_0_I_2_I Zone 34
I_0_I_3_I Zone 35
I_0_I_4_I Zone 36
I_0_I_5_I Zone 37
I_0_I_6_I Zone 38
I_0_I_7_I Zone 39
I_0_I_8_I Zone 40
*66 Report Codes for Zones 41 to 48
I_0_I_1_I Zone 41
I_0_I_2_I Zone 42
I_0_I_3_I Zone 43
I_0_I_4_I Zone 44
I_0_I_5_I Zone 45
I_0_I_6_I Zone 46
I_0_I_7_I Zone 47
I_0_I_8_I Zone 48
*67 Report ID for Zones 41 to 48
I_0_I_1_I Zone 41
I_0_I_2_I Zone 42
I_0_I_3_I Zone 43
I_0_I_4_I Zone 44
I_0_I_5_I Zone 45
I_0_I_6_I Zone 46
I_0_I_7_I Zone 47
I_0_I_8_I Zone 48
*68 Misc Alarms/Restorals for Zones 41 to 48
I_0_I_1_I Alarm/Supervision Restore
I_0_I_1_I Trouble
I_0_I_1_I Trouble Restore
I_0_I_0_I Bypass
I_0_I_0_I Bypass Restore
*69 Report Codes for Zones 49 to 56
I_0_I_1_I Zone 49
I_0_I_2_I Zone 50
I_0_I_3_I Zone 51
I_0_I_4_I Zone 52
I_0_I_5_I Zone 53
I_0_I_6_I Zone 54
I_0_I_7_I Zone 55
I_0_I_8_I Zone 56
*70 Report ID for Zones 49 to 56
I_0_I_1_I Zone 49
I_0_I_2_I Zone 50
I_0_I_3_I Zone 51
I_0_I_4_I Zone 52
I_0_I_5_I Zone 53
I_0_I_6_I Zone 54
I_0_I_7_I Zone 55
I_0_I_8_I Zone 56
*71 Report Codes for Zones 57 to 64
I_0_I_1_I Zone 57
I_0_I_2_I Zone 58
I_0_I_3_I Zone 59
I_0_I_4_I Zone 60
I_0_I_5_I Zone 61
I_0_I_6_I Zone 62
I_0_I_7_I Zone 63
I_0_I_8_I Zone 64
*72 Report ID for Zones 57 to 64
I_0_I_1_I Zone 57
I_0_I_2_I Zone 58
I_0_I_3_I Zone 59
I_0_I_4_I Zone 60
I_0_I_5_I Zone 61
I_0_I_6_I Zone 62
I_0_I_7_I Zone 63
I_0_I_8_I Zone 64
*73 Misc Alarms/Restorals for Zones 49 to 64
I_0_I_1_I Alarm/Supervision Restore
I_0_I_1_I Trouble
I_0_I_1_I Trouble Restore
I_0_I_0_I Bypass
I_0_I_0_I Bypass Restore
*76 Report Codes for Zones 70 to 99
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_4_I Duress
I_0_I_5_I Zone 97 (Polling Loop Short)
I_0_I_6_I Zone 95 (1 & *)
I_0_I_7_I Zone 96 (3 & #)
I_0_I_8_I Zone 99 (* & #)
*77 Report ID for Zones 70 to 99
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_4_I Duress
I_0_I_5_I Zone 97 (Polling Loop Short)
I_0_I_6_I Zone 95 (1 & *)
I_0_I_7_I Zone 96 (3 & #)
I_0_I_8_I Zone 99 (* & #)
*78 Misc Alarms/Restorals for Zones 70 to 99
I_0_I_1_I Alarm/Supervision Restore
I_0_I_1_I Trouble
I_0_I_1_I Trouble Restore
I_0_I_0_I Bypass
I_0_I_0_I Bypass Restore
*79 Zone Type Restore Enable Zone Types 1 to 8
I_0_I Zone Type 1 (Entry/Exit 1)
I_0_I Zone Type 2 (Entry Exit 2)
I_0_I Zone Type 3 (Perimeter)
I_0_I Zone Type 4 (Interior Follower)
I_0_I Zone Type 5 (Day/Night)
I_0_I Zone Type 6 (24 Hour Silent)
I_0_I Zone Type 7 (24 Hour Audible)
I_0_I Zone Type 8 (24 Hour Auxiliary)

0 = No Restoral Report
1 = Restoral Report
*80 Zone Type Restore Enable Zone Types 9 to 10
I_1_I Zone Type 9 (Fire w/o Veri)
I_0_I Zone Type 10 (Int Delay)

0 = No Restoral Report
1 = Restoral Report
*81 Misc Non Alarm Codes
I_0_I_1_I Close
I_0_I_0_I Open
I_0_I_1_I Low Battery
I_0_I_1_I Low Battery Restore
I_0_I_0_I AC Loss
I_0_I_0_I AC Restore
I_0_I_1_I Communicator Test
I_0_I_0_I Power Up
I_0_I_0_I Cancel
I_0_I_1_I Program Tamper
*82 Misc Non Alarm Codes
I_0_I_0_I Open
I_0_I_0_I Close
I_0_I_1_I Low Battery
I_0_I_0_I Low Battery Restore
I_0_I_0_I AC Loss
I_0_I_0_I AC Restore
I_0_I_0_I Communicator Test
I_0_I_0_I Power Up
I_0_I_0_I Cancel
I_0_I_0_I Program Tamper
*83 First Test Report Time I_0_I_0_I I_1_I_2_I I_0_I_0_I
Day Hour Minutes
*84 Swinger Shutdown I_0_I_4_I 00 = Disabled
01 to 15 = 01 to 15 Alarms
*87 Entry Warning I_1_I 0 = 3 Beeps
1 = Continuous
*88 Burglar Alarm Comm Delay I_0_I 0 = No Delay
1 = 16 seconds
*89 Restore Report Timing I_0_I 0 = Instant
1 = At Bell Timeout
2 = At Disarm
*90 Secondary Account Number I__I__I I__I__I I__I__I I__I__I (2 digit entries)
Hex B = 11, C = 12, D = 13, E = 14, F = 15

To access Upper programming press *94, to return to lower programming press *99
the 1 isn’t part of location, to go to a Upper program location press * + 2-digits

1*01 Zone Types for Zones 28 to 32
I_?_I_?_I Zone 28
I_?_I_?_I Zone 29
I_?_I_?_I Zone 30
I_?_I_?_I Zone 31
I_?_I_?_I Zone 32
I_?_I_?_I Zone 38
I_?_I_?_I Zone 39
I_?_I_?_I Zone 40
1*02 Zone Types for Zones 33 to 40
I_?_I_?_I Zone 33
I_?_I_?_I Zone 34
I_?_I_?_I Zone 35
I_?_I_?_I Zone 36
I_?_I_?_I Zone 37
00 = Disabled
01 = Entry/Exit 1
02 = Entry/Exit 2
03 = Instant
04 = Interior
05 = Day Zone
06 = Silent Holdup
07 = Audible Police
08 = 24 Hour Auxiliary
09 = Fire w/o Verification
10 = InteriorDelay
16 = Fire w/Verification
17 = Fire Water Flow
18 = Fire Supervisory
19 = 24 Hour Trouble
1*03 Zone Type for Zone 41 to 48
I_0_I_0_I Zone 41
I_0_I_0_I Zone 42
I_0_I_0_I Zone 43
I_0_I_0_I Zone 44
I_0_I_0_I Zone 45
I_0_I_0_I Zone 46
I_0_I_0_I Zone 47
I_0_I_0_I Zone 48
1*04 Zone Types for Panics
I_0_I_0_I Zone 49
I_0_I_0_I Zone 50
I_0_I_0_I Zone 51
I_0_I_0_I Zone 52
I_0_I_0_I Zone 53
I_0_I_8_I Zone 54
I_0_I_9_I Zone 55
I_0_I_7_I Zone 56
1*05 Zone Type for Zone 57 to 64
I_0_I_0_I Zone 57
I_0_I_0_I Zone 58
I_0_I_0_I Zone 59
I_0_I_0_I Zone 60
I_0_I_0_I Zone 61
I_0_I_0_I Zone 62
I_0_I_0_I Zone 63
I_0_I_0_I Zone 64
1*33 Touch Tone with Rotory Backup I_1_I 0 = Disable
1 = Enable
1*34 Comm Split Report Selection I_0_I 0 = No
1 = Alarms to Primary, others Sec.
2 = O/C/Test Secondary, others Pri.
1*40 System Non-Alarm Codes 1st Digit
I__I Armed Stay
I__I Time Set/Event Log Reset
I__I Event Log 50 & 90% Full
I__I Event Log Overflow
1*41 System Non-Alarm Codes 2nd Digit
I__I Armed Stay
I__I Time Set/Event Log Reset
I__I Event Log 50 & 90% Full
I__I Event Log Overflow
1*43 Perm Keypad Backlight I_1_I 0 = No
1 = Yes
1*45 – Exit Delay Sounder I_1_I 1 = Enable
0 = Disable
1*47 Chime Annunciation on Bell 1 I_1_I 0 = Disable
1 = Enable
1*52 Cancel Report Restriction I_0_I 0 = No Restriction
1 = Within Bell Timeout
1*53 Download Callback I_1_I 0 = Callback Required
1 = No Callback
1*70 Event Log Types I__I Alarm
I__I Check
I__I Bypass
I__I O/C
I__I System
0 = Disable Logging
1 = Enable Logging
1*71 12/24 Hour Time Stamp Format I_0_I 0 = 12 Hour
1 = 24 Hour (Military)
1*72 Event Log Printer On-line Mode I_0_I 0 = Disable
1 = Enable
1*73 Printer Baud Rate I_0_I 0 = 1200 Baud
>
1 = 300 Baud
3*10 Response Type Assignment
I_0_I_0_I Zone 70 Bell 1
I_1_I_9_I Zone 71 Bell 2
I_1_I_9_I Zone 72 Earth Ground
I_1_I_9_I Zone 73 J2/In 1
I_1_I_9_I Zone 74 Dialer 1
I_0_I_0_I Zone 75 Dialer 2
I_0_I_0_I Not Used
I_0_I_0_I Not Used

19 = 24 Hour Trouble
3*15 Alarm Bell Sound I_0_I Bell 1
I_0_I Bell 2
0 = Pulsed
1 = Steady
3*16 Delay for Zone Types 17 & 18 I_0_I_0_I 00 to 15 x2 seconds
(Waterflow & Fire Supervision)
3*17 Alt Function (Tamper) for Zone 6 I_0_I_0_I 0 = Disabled
1 = Enabled
3*19 Enable J2 Header Printer Port I_0_I 0 = Pins 5 & 9 function per 3*20
1 = Pins 5 & 9 as printer RXD & DTR
3*20 Trigger Outputs Selection I_0_I 0 = Lorra Full Connection
1 = Lorra Limited Connection/Keyswitch
2 = Lorra Fire Connection & 5140LED
3*21 Max # of Dialer Retries I_8_I 1 to 8 attempts
3*30 Dialer Selection I_1_I Main
I_1_I Backup
0 = Disabled
1 = Enabled
3*31 Backup Dialer Touch Tone/Rotary I_0_I 0 = Rotary
1 = Touch Tone
3*40 Report Codes for Zone 70 to 77
I_0_I_1_I Zone 70
I_0_I_2_I Zone 71
I_0_I_3_I Zone 72
I_0_I_4_I Zone 73
I_0_I_5_I Zone 74
I_0_I_6_I Zone 75
I_0_I_7_I Zone 76
I_0_I_8_I Zone 77
3*41 ID Digits for Zones 70-77
I_0_I_1_I Zone 70
I_0_I_2_I Zone 71
I_0_I_3_I Zone 72
I_0_I_4_I Zone 73
I_0_I_5_I Zone 74
I_0_I_6_I Zone 75
I_0_I_7_I Zone 76
I_0_I_8_I Zone 77
3*42 Alarms/Restorals for Zone 70 to 77
I_0_I_0_I Alarm/Restorals
I_0_I_0_I Trouble
I_0_I_0_I Trouble Restore
I_0_I_0_I Bypass
I_0_I_0_I Bypass Restore
3*50 Zone Type Restore Enable
For Zone Types 16 to 18
16 = Fire w/Verification
17 = Fire Water Flow
18 = Fire Supervisory
I_1_I Zone Type 16
I_1_I Zone Type 17
I_1_I Zone Type 18
0 = Disabled
1 = Enabled
3*51 Non Alarm Codes 1st Digit
I__I Fire/Burg Walk Test Start
I__I Fire/Burg Walk Test End
3*52 Non Alarm Codes 2nd Digit
I__I Fire/Burg Walk Test Start
I__I Fire/Burg Walk Test End
3*57 Bell 2/Aux Relay Confirm Am Ding I_0_I Bell 2
I_0_I Aux
0 = Disabled
1 = Enabled
3*58 Bell 2/Aux Relay AC Loss Alarm I_0_I Bell 2
I_0_I Aux
0 = Disabled
1 = Enabled
3*59 Bell 2/Aux Relay Chime Annunciation I_0_I Bell 2
I_0_I Aux
0 = Disabled
1 = Enabled
3*60 Bell 2/Aux Relay Timeout I_0_I_0_I Bell 2
I_0_I_0_I Aux
0 = Disabled
1 = Enabled
3*61 Aux Relay Function I_0_I_0_I Bell 2 0 = Trouble/Supervisory
1 = Alarm/Silenced by Code + OFF
2 = Smoke Detector Reset
3 = Battery Save
4 = Alarm, Silenced by
Code + # + 67
3*70 Bell 1 & 2 Aux Relay Activation Zn 1 to 8
I_6_I Zone 1
I_6_I Zone 2
I_5_I Zone 3
I_5_I Zone 4
I_5_I Zone 5
I_5_I Zone 6
I_5_I Zone 7
I_5_I Zone 8
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*71 Bell 1 & 2 Aux Relay Activation Zn 9 to 16
I_0_I Zone 9
I_0_I Zone 10
I_0_I Zone 11
I_0_I Zone 12
I_0_I Zone 13
I_0_I Zone 14
I_0_I Zone 15
I_0_I Zone 16
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*72 Bell 1 & 2 Aux Relay Activation Zn 17 to 24
I_0_I Zone 17
I_0_I Zone 18
I_0_I Zone 19
I_0_I Zone 20
I_0_I Zone 21
I_0_I Zone 22
I_0_I Zone 23
I_0_I Zone 24
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*73 Bell 1 & 2 Aux Relay Activation Zone 25 to 32
I_0_I Zone 25
I_0_I Zone 26
I_0_I Zone 27
I_0_I Zone 28
I_0_I Zone 29
I_0_I Zone 30
I_0_I Zone 31
I_0_I Zone 32
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*74 Bell 1 & 2 Aux Relay Activation Zone 33 to 40
I_0_I Zone 33
I_0_I Zone 34
I_0_I Zone 35
I_0_I Zone 36
I_0_I Zone 37
I_0_I Zone 38
I_0_I Zone 39
I_0_I Zone 40
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*75 Bell 1 & 2 Aux Relay Activation Zone 41 to 48
I_0_I Zone 41
I_0_I Zone 42
I_0_I Zone 43
I_0_I Zone 44
I_0_I Zone 45
I_0_I Zone 46
I_0_I Zone 47
I_0_I Zone 48
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*76 Bell 1 & 2 Aux Relay Activation Zone 49 to 56
I_0_I Zone 49
I_0_I Zone 50
I_0_I Zone 51
I_0_I Zone 52
I_0_I Zone 53
I_0_I Zone 54
I_0_I Zone 55
I_0_I Zone 56
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*77 Bell 1 & 2 Aux Relay Activation Zone 57 to 64
I_0_I Zone 57
I_0_I Zone 58
I_0_I Zone 59
I_0_I Zone 60
I_0_I Zone 61
I_0_I Zone 62
I_0_I Zone 63
I_0_I Zone 64
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*78 Bell 1 & 2 Aux Relay Activation Zone 70 to 72
I_0_I Not Used
I_0_I Not Used
I_0_I Not Used
I_0_I Not Used
I_0_I Not Used
I_0_I Zone 70
I_0_I Zone 71
I_0_I Zone 72
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*79 Bell 1 & 2 Aux Relay Activation Zone 73 to 75
I_0_I Zone 73
I_0_I Zone 74
I_0_I Zone 75
I_0_I Not Used
I_0_I Not Used
I_0_I Not Used
I_0_I Not Used
I_0_I Not Used
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*81 Bell 1 & 2 Aux Relay Activation Zone 95 to 99
I_0_I Not Used
I_0_I Not Used
I_0_I Not Used
I_0_I Not Used
I_0_I Not Used
I_0_I Zone 95 (1 & *)
I_0_I Zone 96 (3 & #)
I_0_I Zone 99 (* & #)
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & 2
4 = Aux Relay
5 = Bell 1 & Relay
6 = Bell 2 & Relay
7 = Bell 1 & 2 & Relay
3*82 Enable Burg Features
(Away, Stay, Max, Test, Instant, Chime Functions)
I_1_I 0 = Disable
1 = Enable
3*85 Enable Fire & System Zone Bypass
(For Zone Types 9, 16, 17 & 18 & Zones 70 to 77)
I_1_I 0 = Not Enabled
1 = Only Installer can Bypass
2 = Only Installer & Master can Bypass