Ademco 5140XM Basics
Zones | Up to 64 Hardwired zones |
Wireless | No |
Battery |
12 volt rechargeable Gel-Cell inside main panel AC Transformer is 16.5 volts |
Downloading | Yes |
Panic Buttons |
Police Panic – * and # Fire Panic – 1 and * Medical Panic – 3 and # |
**Do not pause between keypresses with below commands or they will not work** | |
Status | Press * if keypad shows NOT READY to view open zones |
Arm Away | 4-digit code + 2 (AWAY) to arm everything |
Arm Stay | 4-digit code + 3 (STAY) to arm all but motions |
Quick-Arm | (If Enabled) Press # + 2 for AWAY, # + 3 for STAY |
Instant Arm | 4 digit code + 7 (INSTANT), this also bypasses motions (still gives exit delay) |
Max Arming | 4-digit code + 4 (MAX) and everything arms instant (still gives exit delay) |
Disarm | 4-digit code + 1 (OFF) |
Silence Alarm | 4-digit code + 1 (OFF) twice to turn off siren and reset display |
Bypass | 4-digit code + 6 (BYPASS) + zone (01, 02 03 etc) |
Alarm Memory | 4-digit code + 0, 4-digit code + 1 key (OFF) to exit |
Reset Smoke |
4-digit code + 1 (OFF) twice (If this does NOT reset smoke detector set for service, smoke is bad) |
Door Chimes | 4-digit code + 9 (CHIME) |
Keypad Help | Hold down any key (AWAY, STAY etc) for 5 seconds to show that keys function |
Setting Clock |
4-digit code + #63 6 moves from Hour to Minute to Month to Date to Year 4 moves backwards Press 3 or 1 to change values Press 8 to save and exit, press * to exit without saving |
Fire Drill Test |
Press # 69 to test Fire Alarm sirens Press User code + 1 (OFF) to end |
View Zones | Press and hold * key for 2 or 3 seconds, all Zone descriptions should scroll |
Test Sensors |
4-Digit Code + 5 (TEST) Keypad will beep every 3 minutes Open sensors and keypad will sound End test with 4-digit Code + 1 (OFF) key |
Event Log |
1. Enter User Code + # + 6 + 0, press 0 for Recent Alarms or 1 for Complete 2. Press 3 or 1 keys to select an Event catagory Alarm Event Log Check Event Log (Shows zone troubles) Bypass Event Log (Shows time a zone was bypassed) Open Event Log (Shows type system was armed or disarmed) System Event Log (Shows time for system troubles) All Event Log (Shows all events, alarms or troubles) 3. Press 8 to select an Event catagory, press 8 again to display next event 4. Press * to exit at any time |
Setting Clock |
(some systems may not allow changing Clock) 1. Enter Master Code + # + 63, display will show current Time/Date 2. Enter correct (00 to 12) Hour then press * 3. Enter correct Minutes (00 to 59) then press * 4. Press any key from 0 to 9 to toggle AM and PM then press * 5. Enter correct Month (01 to 12) then press * 6. Enter correct Date (01 to 31) then press * 7. Enter correct Year (99 or 00 etc) then press * 8. Press * after cursor is in the Year setting to exit |