Ademco 5120XM Program

Enter Program 1. Master Code + 8 + 0 + 0 (Display should show 20)
or
2. Power down then back up and press * and # within 1 minute
Move to Location * + LocationAdemco 5120XM Program Sheet
View Location # + Location (Display will read off one digit at a time)
Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00
Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

*20 Master Code I_0_I_0_I_0_I_0_I Default is 5110
*21 Quick Arm Enable I_1_I 0 = No
1 = Yes
*27 Output To Long Range Radio I_0_I 0 = No
1 = Yes
*30 Alarm Bell Timeout I_2_I 1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
4 = 16 minutes
*31 Auxiliary Relay Timeout I_4_I 0 = None
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
4 = 16 minutes
*32 Supervisory on Open/Short I_0_I 0 = Trouble on Open/Supervisory on Short
1 = Supervisory on Open and Short
*33 Back-Up Dialer Pulse/Tone I_0_I 0 = Pulse Dial
1 = Tone Dial
*34 Auxiliary Relay Function I_1_I 0 = Trouble/Supervisory
1 = Alarm
2 = Smoke Detector Reset
3 = Battery Save
4 = Alarm (silenced by Code + #67)
*40 PABX Access Code I__I__I__I__I (If 9 is needed to dial add here)
*41 Primary Phone (12 digits) I__I__I__I__I__I__I__I__I__I__I__I__I
End Phone Number with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause
*42 Secondary Phone (12 digits) I__I__I__I__I__I__I__I__I__I__I__I__I
(Pager only available on VERY new 4110-DL’s, pager will not work if Account starts with 0)
*43 Subscriber Account I__I__I__I__I
(Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15)
*45 Main Dialer Pulse/Tone I_1_I 0 = Pulse Dial
1 = Tone Dial
*46 Report Format I_7_I 0 = 3/1, 4/1 Ademco L/S Standard
1 = 3/1, 4/1 Radionics Standard
2 = 4/2 Ademco L/S Standard
3 = 4/2 Radionics Standard
6 = 4/2 Ademco Express
7 = Contact ID
8 = 3/1, 4/1 Ademco L/S Expanded
9 = 3/1, 4/1 Radionics Expanded
*47 Split/Dual Reporting I_0_I 0 = Backup Report Only
To Primary Phone
1 = Alarms, Restore
2 = All Reports except Test
3 = Alarms, Restore
4 = All Reports except Test
5 = All Reports (Dual Reporting)
To Secondary Phone
All Other Reports
Test
All Reports
All Reports
All Reports
*48 15 Sec Dialer Delay (Burg only) I_0_I 0 = Yes
1 = No
*49 Periodic Test Message I_0_I 0 = None
1 = 24 Hours
2 = Weekly
*50 Sescoa/Radionics Select I_0_I 0 = Radionics
1 = Sescoa
*51 Confirmation of Arming Ding I_0_I 0 = Yes
1 = No
Must use 6139 Alpha Keypad here
*56 Zone Programming Zone 1 to 5 = Hardwire Zones
Zone 6 = Bell Supervisory
Zone 7 = * & #
Zone 10 = Earth Ground
Zone 11 = Main Dialer
Zone 12 = Backup Dialer
Zone 13 = Aux Relay
Zone 95 = 1 & *
Zone 96 = 3 & #
1. “Enter Zn No.” enter zone to program then press * or 00 to quit
2. Keypad will show summary of zones programming, press *
3. “Zone Type?” enter zone type, press *
Common Zones Types 00 = Zone Disabled/Deleted 08 = 24 hour Aux/Medical
01 = Delay Zone 1 09 = Fire without Verification
02 = Not used (never use this one) 10 = Interior with Delay
03 = Perimeter/Instant 16 = Fire with Verification
04 = Interior Follower/Motions 17 = Fire Waterflow
05 = Trouble by Day/Alarm by Night 18 = Fire Sprinkler Supervision
06 = 24 hour Silent/Holdup 19 = 24 Hr Trouble
07 = 24 hour Police Panic
4. “Report Code?” enter Report Code (use 10) then press *
5. “Alpha Program?” press 0 if not programming Alpha descriptions
6. ” Keypad shows new summary of programming or be back to “Enter zone number”
7. If finished programming zones enter 00 at “Enter zone no” to return to normal programming
*57 Zone Type 18 Delay Enable I_1_I 0 = No Delay
(Delay set in field *78) 1 = Yes
*58 Supervisory Report Code I_1_I_0_I
*59 Supervisory Restore Report Code I_0_I_0_I
*60 Trouble Report Code I_1_I_0_I
*61 Bypass Report Code I_0_I_0_I
*62 AC Loss Report Code I_1_I_0_I
*63 Low Bat Report Code I_1_I_0_I
*64 Normal dialer Test Report Code I_1_I_0_I
*65 Open/Exit Alarm Report Code I_0_I_0_I
*66 Away/Stay Close Report Codev I_0_I_0_Iv
*68 Cancel Report Code I_1_I_0_I
*69 Group Restores Trouble/Bypass I_0_I
*70 Alarm Restore Code I_0_I
*71 Trouble Restore Code I_0_I_0_I
*72 Bypass Restore Code I_0_I_0_I
*73 AC Restore Code I_0_I_0_I
*74 Low Bat Rest Code I_0_I_0_I
*76 Waterflow Alarm Silencing I_0_I_0_I 0 = Manual Silence Only
1 = Automatic Silence when Waterflow ceases
*77 Alarm Bell Sound I_1_I 0 = Pulsing
1 = Steady
*78 Zone Types 17 & 18 Delay I_0_I_0_I 00 to 99 seconds
*79 Main/Backup Dialer Enable I_1_I Main 0 = Disabled
I_1_I Backup 1 = Enabled
*82 Custom Alpha Editing
*84 Miscellaneous Report Codes Fire Walk Test Start I_0_I_0_I
Fire Walk Test End I_0_I_0_I
Off-Norm Dialer Test I_0_I_0_I
*85 Zones 1-7 Bell/Aux Relay Activation I_1_I Zone 1
I_1_I Zone 2
I_1_I Zone 3
I_1_I Zone 4
I_1_I Zone 5
I_0_I Zone 6
I_0_I Zone 7
0 = None
1 = Bell
2 = Aux Relay
3 = Bell & Aux Realy
*86 Zones 10-12, 95 & 96
Bell/Aux Relay Activation
I_0_I (Not used)
I_0_I Zone 10
I_0_I Zone 11
I_0_I Zone 12
I_1_I Zone 95
I_0_I Zone 96
0 = None
1 = Bell
2 = Aux Relay
3 = Bell & Aux Realy
*87 Burglary Feature Enable
(Enables Stay, Away, Max, Test, Instant & Chime)
I_1_I 0 = Disabled
1 = Enabled
*92 Reports Per Armed Period I_1_I 0 = 1 Zone Alarm & 1 Restore per Armed Period
1 = Unlimited Reports
*94 Download Phone Number I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I__I
*95 Ring Count I_# 15_I 0 to #15 #15 = Answer Machine Defeat
*96 Reinitialize Download (No Value needed, keypad will beep)
*97 Default Panel (No Value needed, keypad will beep and panel will default to factory)
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0)
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0)