Ademco 5120XM Program
|
||||||||||||
|
||||||||||||
*20 Master Code | I_0_I_0_I_0_I_0_I Default is 5110 | |||||||||||
*21 Quick Arm Enable | I_1_I |
0 = No 1 = Yes |
||||||||||
*27 Output To Long Range Radio | I_0_I |
0 = No 1 = Yes |
||||||||||
*30 Alarm Bell Timeout | I_2_I |
1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
||||||||||
*31 Auxiliary Relay Timeout | I_4_I |
0 = None 1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
||||||||||
*32 Supervisory on Open/Short | I_0_I |
0 = Trouble on Open/Supervisory on Short 1 = Supervisory on Open and Short |
||||||||||
*33 Back-Up Dialer Pulse/Tone | I_0_I |
0 = Pulse Dial 1 = Tone Dial |
||||||||||
*34 Auxiliary Relay Function | I_1_I |
0 = Trouble/Supervisory 1 = Alarm 2 = Smoke Detector Reset 3 = Battery Save 4 = Alarm (silenced by Code + #67) |
||||||||||
*40 PABX Access Code | I__I__I__I__I (If 9 is needed to dial add here) | |||||||||||
*41 Primary Phone (12 digits) |
I__I__I__I__I__I__I__I__I__I__I__I__I End Phone Number with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause |
|||||||||||
*42 Secondary Phone (12 digits) |
I__I__I__I__I__I__I__I__I__I__I__I__I (Pager only available on VERY new 4110-DL’s, pager will not work if Account starts with 0) |
|||||||||||
*43 Subscriber Account |
I__I__I__I__I (Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15) |
|||||||||||
*45 Main Dialer Pulse/Tone | I_1_I |
0 = Pulse Dial 1 = Tone Dial |
||||||||||
*46 Report Format | I_7_I |
0 = 3/1, 4/1 Ademco L/S Standard 1 = 3/1, 4/1 Radionics Standard 2 = 4/2 Ademco L/S Standard 3 = 4/2 Radionics Standard 6 = 4/2 Ademco Express 7 = Contact ID 8 = 3/1, 4/1 Ademco L/S Expanded 9 = 3/1, 4/1 Radionics Expanded |
||||||||||
*47 Split/Dual Reporting | I_0_I | 0 = Backup Report Only | ||||||||||
|
||||||||||||
*48 15 Sec Dialer Delay (Burg only) | I_0_I |
0 = Yes 1 = No |
||||||||||
*49 Periodic Test Message | I_0_I |
0 = None 1 = 24 Hours 2 = Weekly |
||||||||||
*50 Sescoa/Radionics Select | I_0_I |
0 = Radionics 1 = Sescoa |
||||||||||
*51 Confirmation of Arming Ding | I_0_I |
0 = Yes 1 = No |
||||||||||
Must use 6139 Alpha Keypad here | ||||||||||||
*56 Zone Programming |
Zone 1 to 5 = Hardwire Zones Zone 6 = Bell Supervisory Zone 7 = * & # Zone 10 = Earth Ground Zone 11 = Main Dialer Zone 12 = Backup Dialer Zone 13 = Aux Relay Zone 95 = 1 & * Zone 96 = 3 & # |
|||||||||||
1. “Enter Zn No.” enter zone to program then press * or 00 to quit | ||||||||||||
2. Keypad will show summary of zones programming, press * | ||||||||||||
3. “Zone Type?” enter zone type, press * | ||||||||||||
Common Zones Types |
00 = Zone Disabled/Deleted 08 = 24 hour Aux/Medical 01 = Delay Zone 1 09 = Fire without Verification 02 = Not used (never use this one) 10 = Interior with Delay 03 = Perimeter/Instant 16 = Fire with Verification 04 = Interior Follower/Motions 17 = Fire Waterflow 05 = Trouble by Day/Alarm by Night 18 = Fire Sprinkler Supervision 06 = 24 hour Silent/Holdup 19 = 24 Hr Trouble 07 = 24 hour Police Panic |
|||||||||||
4. “Report Code?” enter Report Code (use 10) then press * | ||||||||||||
5. “Alpha Program?” press 0 if not programming Alpha descriptions | ||||||||||||
6. ” Keypad shows new summary of programming or be back to “Enter zone number” | ||||||||||||
7. If finished programming zones enter 00 at “Enter zone no” to return to normal programming | ||||||||||||
*57 Zone Type 18 Delay Enable | I_1_I |
0 = No Delay (Delay set in field *78) 1 = Yes |
||||||||||
*58 Supervisory Report Code | I_1_I_0_I | |||||||||||
*59 Supervisory Restore Report Code | I_0_I_0_I | |||||||||||
*60 Trouble Report Code | I_1_I_0_I | |||||||||||
*61 Bypass Report Code | I_0_I_0_I | |||||||||||
*62 AC Loss Report Code | I_1_I_0_I | |||||||||||
*63 Low Bat Report Code | I_1_I_0_I | |||||||||||
*64 Normal dialer Test Report Code | I_1_I_0_I | |||||||||||
*65 Open/Exit Alarm Report Code | I_0_I_0_I | |||||||||||
*66 Away/Stay Close Report Codev | I_0_I_0_Iv | |||||||||||
*68 Cancel Report Code | I_1_I_0_I | |||||||||||
*69 Group Restores Trouble/Bypass | I_0_I | |||||||||||
*70 Alarm Restore Code | I_0_I | |||||||||||
*71 Trouble Restore Code | I_0_I_0_I | |||||||||||
*72 Bypass Restore Code | I_0_I_0_I | |||||||||||
*73 AC Restore Code | I_0_I_0_I | |||||||||||
*74 Low Bat Rest Code | I_0_I_0_I | |||||||||||
*76 Waterflow Alarm Silencing | I_0_I_0_I |
0 = Manual Silence Only 1 = Automatic Silence when Waterflow ceases |
||||||||||
*77 Alarm Bell Sound | I_1_I |
0 = Pulsing 1 = Steady |
||||||||||
*78 Zone Types 17 & 18 Delay | I_0_I_0_I | 00 to 99 seconds | ||||||||||
*79 Main/Backup Dialer Enable | I_1_I Main |
0 = Disabled I_1_I Backup 1 = Enabled |
||||||||||
*82 Custom Alpha Editing | ||||||||||||
*84 Miscellaneous Report Codes |
Fire Walk Test Start I_0_I_0_I Fire Walk Test End I_0_I_0_I Off-Norm Dialer Test I_0_I_0_I |
|||||||||||
*85 Zones 1-7 Bell/Aux Relay Activation |
I_1_I Zone 1 I_1_I Zone 2 I_1_I Zone 3 I_1_I Zone 4 I_1_I Zone 5 I_0_I Zone 6 I_0_I Zone 7 |
0 = None 1 = Bell 2 = Aux Relay 3 = Bell & Aux Realy |
||||||||||
*86 Zones 10-12, 95 & 96 Bell/Aux Relay Activation |
I_0_I (Not used) I_0_I Zone 10 I_0_I Zone 11 I_0_I Zone 12 I_1_I Zone 95 I_0_I Zone 96 |
0 = None 1 = Bell 2 = Aux Relay 3 = Bell & Aux Realy |
||||||||||
*87 Burglary Feature Enable (Enables Stay, Away, Max, Test, Instant & Chime) |
I_1_I |
0 = Disabled 1 = Enabled |
||||||||||
*92 Reports Per Armed Period | I_1_I |
0 = 1 Zone Alarm & 1 Restore per Armed Period 1 = Unlimited Reports |
||||||||||
*94 Download Phone Number | I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I__I | |||||||||||
*95 Ring Count | I_# 15_I | 0 to #15 #15 = Answer Machine Defeat | ||||||||||
*96 Reinitialize Download (No Value needed, keypad will beep) | ||||||||||||
*97 Default Panel (No Value needed, keypad will beep and panel will default to factory) | ||||||||||||
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) | ||||||||||||
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) |