Ademco 5120XM Basics
Zones | 6 Hardwired |
Battery |
12 volt rechargeable Gel-Cell inside main panel AC Transformer is 16.5 volts, screwed into outlet somewhere in house |
Wireless | No |
Panic Buttons |
Police Panic – * and # (Original 4110’s only have Police Panic) Medical Panic – 1 and * Fire Panic – 3 and # |
Status | Press * if keypad shows NOT READY to view open zones |
Arm AWAY | 4-digit code + 2 (AWAY) |
Arm STAY | 4-digit code + 3 (STAY) |
Instant Arm | 4 digit code + 7 (INSTANT) |
Max Arming | 4-digit code + 4 (MAX), arms everything including motions instant |
Quick-Arm | (If Enabled) Press # + 2 for AWAY, # + 3 for STAY |
Disarm | 4 digit code + 1 (OFF) |
Silence Alarm | 4 digit code + 1 (OFF) twice to turn off siren and reset display |
Bypass |
4-digit code + 6 (BYPASS) + zone (01, 02 etc), BYPASS and zone should display (If this does not work try User Code + zone 1 to 6 instead) |
Alarm Memory | There is no alarm memory or event buffer |
Fire Drill Test |
Master or User Code 2 + # + 69 (sounds siren) End with Master or User Code 2 + OFF |
Fire Walk Test | Master Code + # + 68 |
Sensor Test |
Master Code + 5, keypad will beep every 15 seconds, activating sensors will beep keypad Master Code + OFF ends |
Reset Smoke |
4-digit code + 1 (OFF) twice to turn off siren and reset smoke (If this does NOT reset smoke detector set for service, smoke is bad) |
Door Chimes | 4-digit code + 9 (CHIME) CHIME should appear on keypad display |
Test Sensors |
4-Digit Code + 5 (TEST) Keypad will beep every 3 minutes Open sensors and keypad will sound End test with 4-digit Code + 1 (OFF) key |