Ademco 4140XMPT Program

Enter Program 4140 + 8 + 0 + 0 (Display should show 00)
or Power down then back up and press * and # within 1 minute
(If exiting programming you can re-enter within 1 minute by pressing * and #)
Move to Location * + Location
View Location # + Location (Display will read off one digit at a time)
Exit Program *99
Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

*00 Installer Code I_4_I_1_I_4_I_0_I
*01 Master Code I_1_I_2_I_3_I_4_I
*02 Zone Types Zone 1 to 8
I_ _I_ _I Zone 1
I_ _I_ _I Zone 2
I_ _I_ _I Zone 3
I_ _I_ _I Zone 4
I_ _I_ _I Zone 5
I_ _I_ _I Zone 6
I_ _I_ _I Zone 7
I_ _I_ _I Zone 8
*03 Zone Types Zone 9 to 16
I_ _I_ _I Zone 9
I_ _I_ _I Zone 10
I_ _I_ _I Zone 11
I_ _I_ _I Zone 12
I_ _I_ _I Zone 13
I_ _I_ _I Zone 14
I_ _I_ _I Zone 15
I_ _I_ _I Zone 16
00 = Disabled
01 = Entry/Exit 1
02 = Entry/Exit 2
03 = Instant
04 = Interior
05 = Day Zone
06 = Holdup
07 = Police
08 = Medical
09 = Fire
10 = Interior/Delay
*04 Zone Types Zone 17 to 24
I_ _I_ _I Zone 17
I_ _I_ _I Zone 18
I_ _I_ _I Zone 19
I_ _I_ _I Zone 20
I_ _I_ _I Zone 21
I_ _I_ _I Zone 22
I_ _I_ _I Zone 23
I_ _I_ _I Zone 24
*05 Zone Types Zone 25- 27 & Panics
I_ _I_ _I Zone 25
I_ _I_ _I Zone 26
I_ _I_ _I Zone 27
I_0_I_0_I Not Used
I_0_I_0_I Polling Loop Short
I_0_I_9_I 1 & * A Panic (Fire) Key
I_0_I_8_I 3 & # C Panic (Medical) Key
I_0_I_7_I * & # B Panic (Police) Key
*06 Right Loop Zones 10 to 16 I_1_I_1_I_1_I_1_I_1_I_1_I 0 = No 1 = Yes
*07 Right Loop Zones 17 to 24 I_1_I_1_I_1_I_1_I_1_I_1_I
*08 Right Loop Zones 25 to 32 I_1_I_1_I_1_I_1_I_1_I_1_I
*09 Entry Delay I_0_I_2_I 00 to 15 x15 seconds
*10 Exit Delay 1 I_0_I_4_I 00 to 15 x15 seconds
*11 Entry Delay I_0_I_2_I 00 to 15 x15 seconds
*12 Exit Delay 2 I_0_I_4_I 00 to 15 x15 seconds
*13 Alarm Sounder Duration I_0_I_4_I 00 to 15 x2 minutes
*14 Zone 9 Response I_0_I 0 = Slow 1 = Fast
*15 Keyswitch Enable I_0_I 0 = Disable 1 = Enable
*16 Confirmation of Arming Ding I_0_I 0 = Disable 1 = Enable
*17 AC Loss Keypad Sounding I_1_I 0 = No 1 = Yes
*18 AC Loss Siren I_0_I 0 = No 1 = Yes
*19 Random AC Loss Report I_0_I 0 = No 1 = Yes
*21 Disable Fire Timeout I_0_I 0 = No 1 = Yes
*23 Multiple Alarms I_1_I 0 = No 1 = Yes
*24 4190WH Tamper Disable I_0_I 0 = Enable 1 = Disable
*25 Burg Trigger for Zone Resp 8 I_1_I 0 = No 1 = Yes
*26 Intelligent Test Reporting I_1_I 0 = No 1 = Yes
*27 Test Report Interval I_0_I_0_I_0_I 000 (Disabled) to 199 Hours
*28 Power Up in Previous State I_1_I 0 = No 1 = Yes
*29 Quick Arm I_1_I 0 = No 1 = Yes
*30 Touch Tone Dialing I_1_I 0 = Rotary 1 = Touch Tone
*31 PABX Access Code I_ _I_ _I_ _I_ _I (To dial 9 add here)
*32 Primary Account Number I_ 0_I_ _I_0_I_ _I_0_I_ _I_0_I_ _I (2 digit entries)
Hex B = 11, C = 12, D = 13, E = 14, F = 15
*33 Primary Phone Number (12 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause
*34 Secondary Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*35 Download Phone Number I_1_I_8_I_0 I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I_ _I
*36 CSID Number I 1_I 5_I 1_I 5_I 1_I 5_I 1_I 5_I 1_I 5_I 1_I 5_I 1_I 5_I 1_I 5_I
(15’s Default CSID to Factory)
*37 Download Commands Enable I_1_I Dialer Shutdown
I_1_I System Shutdown
I_0_I Not Used
I_1_I Remote Bypass
I_1_I Remote Disarm
I_1_I Remote Arm
I_1_I Upload Programming
I_1_I Download Programming
0 = No
1 = Yes
*38 Inhibit Bypass of a Zone I_0_I_0_I 00 = All Zones bypassable
*39 Open/Close Report Users 1 to 8 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I 0 = No 1 = No
*40 Open/Close Report Users 9 to 16 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
*41 Normally Closed Zones 2-8 I_0_I 0 = EOL Resistors
1 = Normally Closed Loops
*42 Dial Tone Pause I_0_I 0 = 5 seconds
1 = 11 seconds
2 = 30 seconds
*43 Dial Tone Detection I_0_I 0 = Disable 1 = Enable
*44 Ring Detection Count I_1_I_5_I 15 = Answering Machine Defeat
*45 Primary Format I_1_I 0 = Ademco Lo
1 = Contact ID
2 = Ademco High Speed
3 = Ademco Express
*46 Low Speed Format Primary I_0_I 0 = Ademco Lo
1 = Sescoa/Radionics
*47 Secondary Format I_1_I
*48 Low Speed Format Secondary I_0_I
*49 Checksum Verification I_0_I Primary
I_0_I Secondary
0 = No
1 = Yes
*50 Sescoa Radionics Select I_0_I 0 = Radionics
1 = Sescoa
*51 Dual Reporting I_0_I 0 = No 1 = Yes
*52 Standard/Exp Primary Report I_1_I_1_I_1_I_1_I_1_I_1_I 0 = Standard
1 = Expanded
*53 Standard/Exp Secondary Report I_1_I_1_I_1_I_1_I_1_I_1_I
*54 Alarm Report Codes Zone 1 to 8
I_1_I_1_I Zone 1
I_1_I_1_I Zone 2
I_1_I_1_I Zone 3
I_1_I_1_I Zone 4
I_1_I_1_I Zone 5
I_1_I_1_I Zone 6
I_1_I_1_I Zone 7
I_1_I_1_I Zone 8
*55 Extended Report Codes Zone 1 to 8
I_0_I_0_I Zone 1
I_0_I_0_I Zone 2
I_0_I_0_I Zone 3
I_0_I_0_I Zone 4
I_0_I_0_I Zone 5
I_0_I_0_I Zone 6
I_0_I_0_I Zone 7
I_0_I_0_I Zone 8
*56 Alarm Report Codes Zone 9 to 16
I_1_I_1_I Zone 9
I_1_I_1_I Zone 10
I_1_I_1_I Zone 11
I_1_I_1_I Zone 12
I_1_I_1_I Zone 13
I_1_I_1_I Zone 14
I_1_I_1_I Zone 15
I_1_I_1_I Zone 16
*57 Extended Report Codes Zone 9 to 16
I_0_I_0_I Zone 9
I_0_I_0_I Zone 10
I_0_I_0_I Zone 11
I_0_I_0_I Zone 12
I_0_I_0_I Zone 13
I_0_I_0_I Zone 14
I_0_I_0_I Zone 15
I_0_I_0_I Zone 16
*58 Restore Trouble Codes Zone 1 to 16
I_0_I_0_I Zone Restore
I_0_I_0_I Zone Trouble
I_0_I_0_I Zone Trouble Restore
I_0_I_0_I Zone Bypass
I_0_I_0_I Zone Bypass Restore
*59 Alarm Report Codes Zone 17 to 24
I_1_I_1_I Zone 17
I_1_I_1_I Zone 18
I_1_I_1_I Zone 19
I_1_I_1_I Zone 20
I_1_I_1_I Zone 21
I_1_I_1_I Zone 22
I_1_I_1_I Zone 23
I_1_I_1_I Zone 24
*60 Extended Report Codes Zone 17 to 24
I_0_I_0_I Zone 17
I_0_I_0_I Zone 18
I_0_I_0_I Zone 19
I_0_I_0_I Zone 20
I_0_I_0_I Zone 21
I_0_I_0_I Zone 22
I_0_I_0_I Zone 23
I_0_I_0_I Zone 24
*61 Alarm Report Codes Zone 25 to 32
I_1_I_1_I Zone 25
I_1_I_1_I Zone 26
I_1_I_1_I Zone 27
I_1_I_1_I Zone 28
I_1_I_1_I Zone 29
I_1_I_1_I Zone 30
I_1_I_1_I Zone 31
I_1_I_1_I Zone 32
*62 Extended Report Codes Zone 25 to 32
I_0_I_0_I Zone 25
I_0_I_0_I Zone 26
I_0_I_0_I Zone 27
I_0_I_0_I Zone 28
I_0_I_0_I Zone 29
I_0_I_0_I Zone 30
I_0_I_0_I Zone 31
I_0_I_0_I Zone 32
*63 Restore Trouble Codes Zone 17 to 32
I_0_I_0_I Zone Restore
I_0_I_0_I Zone Trouble
I_0_I_0_I Zone Trouble Restore
I_0_I_0_I Zone Bypass
I_0_I_0_I Zone Bypass Restore
*64 Alarm Report Codes Zone 33 to 40
I_1_I_1_I Zone 33
I_1_I_1_I Zone 34
I_1_I_1_I Zone 35
I_1_I_1_I Zone 36
I_1_I_1_I Zone 37
I_1_I_1_I Zone 38
I_1_I_1_I Zone 39
I_1_I_1_I Zone 40
*65 Extended Report Codes Zone 33 to 40
I_0_I_0_I Zone 33
I_0_I_0_I Zone 34
I_0_I_0_I Zone 35
I_0_I_0_I Zone 36
I_0_I_0_I Zone 37
I_0_I_0_I Zone 38
I_0_I_0_I Zone 39
I_0_I_0_I Zone 40
*66 Alarm Report Codes Zone 41 to 48
I_1_I_1_I Zone 41
I_1_I_1_I Zone 42
I_1_I_1_I Zone 43
I_1_I_1_I Zone 44
I_1_I_1_I Zone 45
I_1_I_1_I Zone 46
I_1_I_1_I Zone 47
I_1_I_1_I Zone 48
*67 Extended Report Codes Zone 41 to 48
I_0_I_0_I Zone 41
I_0_I_0_I Zone 42
I_0_I_0_I Zone 43
I_0_I_0_I Zone 44
I_0_I_0_I Zone 45
I_0_I_0_I Zone 46
I_0_I_0_I Zone 47
I_0_I_0_I Zone 48
*68 Restore/Trouble Codes Zone 33 to 48
I_0_I_0_I Zone Restore
I_0_I_0_I Zone Trouble
I_0_I_0_I Zone Trouble Restore
I_0_I_0_I Zone Bypass
I_0_I_0_I Zone Bypass Restore
*69 Alarm Report Codes Zone 49 to 56
I_1_I_1_I Zone 49
I_1_I_1_I Zone 50
I_1_I_1_I Zone 51
I_1_I_1_I Zone 52
I_1_I_1_I Zone 53
I_1_I_1_I Zone 54
I_1_I_1_I Zone 55
I_1_I_1_I Zone 56
*70 Extended Report Codes Zone 49 to 56
I_0_I_0_I Zone 49
I_0_I_0_I Zone 50
I_0_I_0_I Zone 51
I_0_I_0_I Zone 52
I_0_I_0_I Zone 53
I_0_I_0_I Zone 54
I_0_I_0_I Zone 55
I_0_I_0_I Zone 56
*71 Alarm Report Codes Zone 57 to 64
I_1_I_1_I Zone 57
I_1_I_1_I Zone 58
I_1_I_1_I Zone 59
I_1_I_1_I Zone 60
I_1_I_1_I Zone 61
I_1_I_1_I Zone 62
I_1_I_1_I Zone 63
I_1_I_1_I Zone 64
*72 Extended Report Codes Zone 57 to 64
I_0_I_0_I Zone 57
I_0_I_0_I Zone 58
I_0_I_0_I Zone 59
I_0_I_0_I Zone 60
I_0_I_0_I Zone 61
I_0_I_0_I Zone 62
I_0_I_0_I Zone 63
I_0_I_0_I Zone 64
*73 Restore/Trouble Codes Zone 49 to 64
I_0_I_0_I Zone Restore
I_0_I_0_I Zone Trouble
I_0_I_0_I Zone Trouble Restore
I_0_I_0_I Zone Bypass
I_0_I_0_I Zone Bypass Restore
*74 Alarm Report for RF RCVR & Panics
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Zone 87 4284 Voice Mdl Sprvsry
I_0_I_0_I Zone 88 Rcvr Not Seeing Trnsmttr
*75 Extended Report for RF RCVR & Panics
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Zone 87
I_0_I_0_I Zone 88
*76 Alarm Report for RF RCVR & Panics
I_0_I_0_I Zone 89 Receiver not Responding
I_0_I_0_I Zone 90 Rcver not seeing xmitter
I_0_I_0_I Zone 91 Receiver not Responding
I_1_I_1_I Duress
I_0_I_0_I Zone 97 Polling Loop Short
I_1_I_1_I Zone 95 1 & * A Fire Panic
I_1_I_1_I Zone 96 3 & # C Medical Panic
I_1_I_1_I Zone 99 * & # B Police Panic
*77 Extended Report for RF RCVR & Panics
I_0_I_0_I Zone 89
I_0_I_0_I Zone 90
I_0_I_0_I Zone 91
I_0_I_0_I Duress
I_0_I_0_I Zone 97
I_0_I_0_I Zone 95
I_0_I_0_I Zone 96
I_0_I_0_I Zone 99
*78 Restore/Trouble for RF RCVR & Panics
I_0_I_0_I Zone Restore
I_0_I_0_I Zone Trouble
I_0_I_0_I Zone Trouble Restore
I_0_I_0_I Zone Bypass
I_0_I_0_I Zone Bypass Restore
*79 Zone Restore Enable Zones 1 -8 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I 0 = Disable 1 = Enable
*80 Zone Restore Enable Zones 9 -10 I_0_I_0_I 0 = Disable 1 = Enable
*81 System Non-Alarm Codes
I_0_I_0_I Close
I_0_I_0_I Open
I_1_I_1_I Low Battery
I_0_I_0_I Low Battery Restore
I_1_I_1_I AC Loss
I_0_I_0_I AC Loss Restore
I_0_I_0_I Test
I_0_I_0_I Power
I_1_I_1_I Cancel
I_0_I_0_I Program Tamper
*82 System Non-Alarm Codes 2nd Digit
I_0_I_0_I Close
I_0_I_0_I Open
I_0_I_0_I Low Batter
I_0_I_0_I Low Battery Rest
I_0_I_0_I AC Loss
I_0_I_0_I AC Loss Rest
I_0_I_0_I Test
I_0_I_0_I Power
I_0_I_0_I Cancel
I_0_I_0_I Program Tamp
*83 First Test Report Time I_0_I_0_I I_1_I_2_I I_0_I_0_I
*84 Swinger Shutdown I_0_I_3_I 00 (Disabled) to 15 Alarms
*86 Zone Expander Device I_0_I 0 = More than 1 4208 Used
1 = Only 1 4208 Used
*87 Entry Warning I_0_I 1 = Continuous
0 = 3 beeps
*88 Burg Alarm Comm Delay I_0_I 0 = No Delay
1 = 16 seconds
*89 Restore Report Timing I_0_I 0 = Instant as Zone restores
1 = After bell timeout
2 = When disarmed
*90 2nd Account Number I_ _I_ _I_ _I_ _I
*93 5137 LCD Keypad Programming

*94 Load Communication Defaults (Preset Program Defaults)
*80 Loads Low Speed
*81 Loads Ademco Exp
*82 Loads Ademco Hi Speed
*83 Loads Contact ID

*97 Default Panel (No Value needed, keypad will beep and default panel)
For Upper Level Programming press *94
To go to an Upper Level Location press *00 to *01 etc
To return to lower programming press *99
Upper Level Programming

1*00 Open/Close Report Enable
I_0_I User 17
I_0_I User 18
I_0_I User 19
I_0_I User 20
I_0_I User 21
I_0_I User 22
I_0_I User 23 to 70
0 = No
1 = Yes
1*01 Zone Types Zone 28 to 32
I_ _I_ _I Zone 28
I_ _I_ _I Zone 29
I_ _I_ _I Zone 30
I_ _I_ _I Zone 31
I_ _I_ _I Zone 32
1*02 Zone Types Zone 33 to 40
I_ _I_ _I Zone 33
I_ _I_ _I Zone 34
I_ _I_ _I Zone 35
I_ _I_ _I Zone 36
I_ _I_ _I Zone 37
I_ _I_ _I Zone 38
I_ _I_ _I Zone 39
I_ _I_ _I Zone 40
00 = Disabled
01 = Entry/Exit
02 = Entry/Exit 2
03 = Instant
04 = Interior
05 = Day Zone
06 = Holdup
07 = Police
08 = Medical
09 = Fire
10 = Interior/Delay
1*04 Zone Types Zone 41 to 48
I_ _I_ _I Zone 41
I_ _I_ _I Zone 42
I_ _I_ _I Zone 43
I_ _I_ _I Zone 44
I_ _I_ _I Zone 45
I_ _I_ _I Zone 46
I_ _I_ _I Zone 47
I_ _I_ _I Zone 48
1*04 Zone Types Zone 49 to 56
I_ _I_ _I Zone 49
I_ _I_ _I Zone 50
I_ _I_ _I Zone 51
I_ _I_ _I Zone 52
I_ _I_ _I Zone 53
I_ _I_ _I Zone 54
I_ _I_ _I Zone 55
I_ _I_ _I Zone 56
1*05 Zone Types for Zones 57 to 64
I_ _I_ _I Zone 57
I_ _I_ _I Zone 58
I_ _I_ _I Zone 59
I_ _I_ _I Zone 60
I_ _I_ _I Zone 61
I_ _I_ _I Zone 62
I_ _I_ _I Zone 63
I_ _I_ _I Zone 64
1*06 Not Used
1*07 Not Used
1*08 Receiver & Voice Module Supervision
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Zone 87 4284 Voice Module Sprvsry
I_0_I_0_I Zone 88 2nd Receiver
1*09 1st & 2nd Receiver Troubles
I_?_I_?_I Zone 89 2nd Receiver
I_?_I_?_I Zone 90 1st Receiver
I_?_I_?_I Zone 91 1st Receiver
1*10 Right Loop Zones 33 to 40 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I 0 = No 1 = Yes
1*11 Right Loop Zones 41 to 48 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*12 Right Loop Zones 49 to 56 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*13 Right Loop Zones 57 to 64 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*18 Enable Wireless Zones 1 to 8 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*19 Enable Wireless Zones 9 to 16 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*20 Enable Wireless Zones 17 to 24 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*21 Enable Wireless Zones 25 to 32 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*22 Enable Wireless Zones 33 to 40 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*23 Enable Wireless Zones 41 to 48 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*24 Enable Wireless Zones 49 to 56 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*25 Enable Wireless Zones 57 to 63 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*26 First RF Receiver Select I_0_I 0 = No 1 = Yes
1*27 Second RF Receiver Select I_0_I 0 = No 1 = Yes
1*28 RF Low Battery Sound I_0_I 0 = Disarmed 1 = Immediate
1*29 RF Low Battery Report Enable I_1_I 0 = Disable 1 = Enable
1*30 RF RCVR Check-IN Interval I_0_I_6_I 00 = Disabled 02 to 15×2 Hours
1*31 RF Transmitter Check in Interval I_1_I_2_I 00 = Disabled 02 to 15×2 Hours
1*32 RF Receiver Type I_0_I 0 = None or 4280 1 = 4281
1*33 Touch-Tone W/Rotary Backup I_1_I 0 = No 1 = Yes
1*34 Comm Split Report Selection I_1_I 0 = No
1 = Alarms Primary
2 = O/C Secondary
1*35 to 1*39 Not Used
1*40 – Armed Stay Report 1st Digit I_0_I_0_I
1*41 Armed Stay Report 2nd Digit I_0_I_0_I
1*44 RF Keypad Tamper Detect I_0_I 0 = No 1 = Yes
1*45 Enable Exit Beeps I_1_I 0 = No 1 = Yes
1*46 Aux Output Enable I_0_I 0 = Ground Start
1 = O/C Trigger
2 = Console Sound
1*47 Chime on External Sounder I_0_I 0 = Disable 1 = Enable
1*48 Wireless Keypad Disable I_0_I 0 = Disable 1 = Enable
1*49 Suppress Trouble Sound for RF I_1_I 0 = Disable 1 = Enable
1*50 Babysitter Code User 22 I_1_I 0 = Disable 1 = Enable
1*51 4281 House ID (for 5700 wireless) I_0_I_0_I 00 (Disabled) to 31
1*52 Cancel Report Restriction I_0_I 0 = Timeout
1 = None
1*53 Download Callback I_1_I 0 = Yes
1 = No Callback
1*54 High Security Mode I_1_I 0 = 4-digit Codes
1 = 6-digits
1*66 4284 Voice Mod Access Code I_0_I_0_I 1st Digit
I_1_I_1_I 2nd Digit 11 = *, 12 = #
00 (Disabled) to 09