Ademco 4120XM Program

Enter Program 4120 + 8 + 0 + 0 (Display should show 00)
or Power down then back up and press * and # within 1 minute
(If exiting programming you can re-enter within 1 minute by pressing * and #)
Move to Location *+ Location
View Location # + Location (Display will read off one digit at a time)
Exit Program *99
Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

*00 Installer Code I_4_I_1_I_2_I_0_I
*01 Master Code I_?_I_?_I_?_I_?_I
*02 Zone Types for Zones 1 to 8 I_?_I_?_I Zone 1
I_?_I_?_I Zone 2
I_?_I_?_I Zone 3
I_?_I_?_I Zone 4
I_?_I_?_I Zone 5
I_?_I_?_I Zone 6
I_?_I_?_I Zone 7
I_?_I_?_I Zone 8
00 = Disabled
01 = Entry/Exit 1
02 = Entry/Exit 2
03 = Instant
04 = Interior
05 = Day Zone
06 = Holdup
07 = Police
08 = Medical
09 = Fire
10 = Interior/Delay
*03 Zone Types for Zones 9 to 16 I_?_I_?_I Zone 9
I_?_I_?_I Zone 10
I_?_I_?_I Zone 11
I_?_I_?_I Zone 12
I_?_I_?_I Zone 13
I_?_I_?_I Zone 14
I_?_I_?_I Zone 15
I_?_I_?_I Zone 16
*04 Zone Types for Zones 17 to 24 I_?_I_?_I Zone 17
I_?_I_?_I Zone 18
I_?_I_?_I Zone 19
I_?_I_?_I Zone 20
I_?_I_?_I Zone 21
I_?_I_?_I Zone 22
I_?_I_?_I Zone 23
I_?_I_?_I Zone 24
*05 Zone Types for Zones 25 to 27

& Panics
I_?_I_?_I Zone 25
I_?_I_?_I Zone 26
I_?_I_?_I Zone 27
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_9_I 1 & * / A Panic Key (Keypad Fire)
I_0_I_8_I 3 & # / C Panic Key (Keypad Medical)
I_0_I_7_I * & # / B Panic Key (Keypad Police)
*06 to *08 Not Used
*09 Entry Delay I_0_I_2_I 0 to 15 x15 seconds
*10 Exit Delay 1 I_0_I_4_I 0 to 15 x15 seconds
*11 Entry Delay I_0_I_2_I 0 to 15 x15 seconds
*12 Exit Delay 2 I_0_I_4_I 0 to 15 x15 seconds
*13 Alarm Sounder Duration I_0_I_4_I 0 to 15 x2 minutes
*14 Zone 8 Fast/Slow Response I_0_I 0 = Slow
1 = Fast
*15 Keyswitch Enable I_0_I 0 = Disable
1 = Enable
*16 Confirmation of Arming Ding I_0_I 0 = Disable
1 = Enable
*17 AC Loss Keypad Sounding I_1_I 0 = No
1 = Yes
*18 AC Loss Siren I_0_I 0 = No
1 = Yes
*19 Randomize AC Loss Report I_0_I 0 = No
1 = Yes
*21 Disable Fire Timeout I_0_I 0 = No
1 = Yes
*23 Multiple Alarms I_1_I 0 = No
1 = Yes
*24 Not Used
*25 Burg Trigger for Zone Resp 8 I_1_I 0 = No
1 = Yes
*26 Intelligent Test Reporting I_1_I 0 = No
1 = Yes
*27 Test Report Interval I_1_I_6_I_8_I 001 – 199 Hrs, 000 = Disabled
*28 Power Up in Previous State I_1_I 0 = No
1 = Yes
*29 Quick Arm I_1_I 0 = No
1 = Yes
*30 Touch Tone Dialing I_1_I 0 = Rotary
1 = Touch Tone
*31 PABX Access Code I__I__I__I__I (To dial 9 add here)
*32 Primary Account Number I_0_I_?_I_0_I_?_I_0_I_?_I_0_I_?_I (2 digit entries)
(Account 1234 = 01 02 03 04) 10 = A, 11 = B, 12 = C, 13 = D, 14 = E, 15 = F,
*33 Primary Phone Number (12 digits) I__I__I__I__I__I__I__I__I__I__I__I__I
End Phone with * # + 11 = *, # + 12 = #, # + 13 = 2.5 second pause
*34 Secondary Phone Number I__I__I__I__I__I__I__I__I__I__I__I__I
*35 Download Phone Number I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I__I
*36 CSID Number I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I
15’s Default CSID to Factory
*37 Download Commands Enable I_1_I Dialer Shutdown
I_1_I System Shutdown
I_0_I Not Used
I_1_I Remote Bypass
I_1_I Remote Disarm
I_1_I Remote Arm
I_1_I Upload Programming
I_1_I Download Programming
0 = No
1 = Yes
*38 Inhibit Bypass of a Zone I_0_I_0_I 00 = All Zones bypassable
*39 Open/Close Report Users 1 to 8 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I 0 = No
*40 Open/Close Report Users 9 to 16 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I 1 = Yes
*41 Normally Closed Zones 2-8 I_0_I 0 = EOL Resistors
1 = Normally Closed
*42 Dial Tone Pause I_0_I 0 = 5 seconds
1 = 11 seconds
2 = 30 seconds
*43 Dial Tone Detection I_0_I 0 = Disable
1 = Enable
*44 Ring Detection Count I_1_I_5_I 15 = Answering Machine
*45 Primary Format I_1_I 0 = Ademco Lo
1 = Contact ID
2 = Ademco High Speed
3 = Ademco Express
*46 Low Speed Format Primary I_0_I 0 = Ademco Lo
1 = Sescoa/Radionics
*47 Secondary Format I_1_I 0 = Ademco Lo
1 = Contact ID
2 = Ademco High Speed
3 = Ademco Express
*48 Low Speed Format Secondary I_0_I 0 = Ademco Lo
1 = Sescoa/Radionics
*49 Checksum Verification I_0_I Primary
I_0_I Secondary
0 = No
1 = Yes
*50 Sescoa Radionics Select I_0_I 0 = Radionics
1 = Sescoa
*51 Dual Reporting I_0_I 0 = No
1 = Yes
*52 Standard/Exp Primary Report I_1_I_1_I_1_I_1_I_1_I_1_I 0 = Standard
*53 Standard/Exp Secondary Report I_1_I_1_I_1_I_1_I_1_I_1_I 1 = Expanded
*54 Alarm Report Codes Zones 1 to 8 *55 Extended Report Codes Zones 1 to 8
I_1_I_1_I Zone 1
I_1_I_1_I Zone 2
I_1_I_1_I Zone 3
I_1_I_1_I Zone 4
I_1_I_1_I Zone 5
I_1_I_1_I Zone 6
I_1_I_1_I Zone 7
I_1_I_1_I Zone 8
I_0_I_0_I Zone 1
I_0_I_0_I Zone 2
I_0_I_0_I Zone 3
I_0_I_0_I Zone 4
I_0_I_0_I Zone 5
I_0_I_0_I Zone 6
I_0_I_0_I Zone 7
I_0_I_0_I Zone 8
*56 Alarm Report Codes Zones 9 to 16 *57 Extended Report Codes Zones 9 to 16
I_1_I_1_I Zone 9
I_1_I_1_I Zone 10
I_1_I_1_I Zone 11
I_1_I_1_I Zone 12
I_1_I_1_I Zone 13
I_1_I_1_I Zone 14
I_1_I_1_I Zone 15
I_1_I_1_I Zone 16
I_0_I_0_I Zone 9
I_0_I_0_I Zone 10
I_0_I_0_I Zone 11
I_0_I_0_I Zone 12
I_0_I_0_I Zone 13
I_0_I_0_I Zone 14
I_0_I_0_I Zone 15
I_0_I_0_I Zone 16
*58 Restore/Trouble Codes Zones 1 to 16
I_0_I_0_I Zone Restore
I_0_I_0_I Zone Trouble
I_0_I_0_I Zone Trouble Restore
I_0_I_0_I Zone Bypass
I_0_I_0_I Zone Bypass Restore
*59 Alarm Report Codes Zones 17 to 24 *60 Extended Report Codes Zones 17 to 24
I_1_I_1_I Zone 17
I_1_I_1_I Zone 18
I_1_I_1_I Zone 19
I_1_I_1_I Zone 20
I_1_I_1_I Zone 21
I_1_I_1_I Zone 22
I_1_I_1_I Zone 23
I_1_I_1_I Zone 24
I_0_I_0_I Zone 17
I_0_I_0_I Zone 18
I_0_I_0_I Zone 19
I_0_I_0_I Zone 20
I_0_I_0_I Zone 21
I_0_I_0_I Zone 22
I_0_I_0_I Zone 23
I_0_I_0_I Zone 24
*61 Alarm Report Codes Zones 25 to 32 *62 Extended Report Codes Zones 25 to 32
I_1_I_1_I Zone 25
I_1_I_1_I Zone 26
I_1_I_1_I Zone 27
I_1_I_1_I Zone 28
I_1_I_1_I Zone 29
I_1_I_1_I Zone 30
I_1_I_1_I Zone 31
I_1_I_1_I Zone 32
I_0_I_0_I Zone 25
I_0_I_0_I Zone 26
I_0_I_0_I Zone 27
I_0_I_0_I Zone 28
I_0_I_0_I Zone 29
I_0_I_0_I Zone 30
I_0_I_0_I Zone 31
I_0_I_0_I Zone 32
*63 Restore/Trouble Codes Zones 17 to 32
I_0_I_0_I Zone Restore
I_0_I_0_I Zone Trouble
I_0_I_0_I Zone Trouble Restore
I_0_I_0_I Zone Bypass
I_0_I_0_I Zone Bypass Restore
*64 Alarm Report Codes Zones 33 to 40 *65 Extended Report Codes Zones 33 to 40
I_1_I_1_I Zone 33
I_1_I_1_I Zone 34
I_1_I_1_I Zone 35
I_1_I_1_I Zone 36
I_1_I_1_I Zone 37
I_1_I_1_I Zone 38
I_1_I_1_I Zone 39
I_1_I_1_I Zone 40
I_0_I_0_I Zone 33
I_0_I_0_I Zone 34
I_0_I_0_I Zone 35
I_0_I_0_I Zone 36
I_0_I_0_I Zone 37
I_0_I_0_I Zone 38
I_0_I_0_I Zone 39
I_0_I_0_I Zone 40
*66 Alarm Report Codes Zones 41 to 48 *67 Extended Report Codes Zones 41 to 48
I_1_I_1_I Zone 41
I_1_I_1_I Zone 42
I_1_I_1_I Zone 43
I_1_I_1_I Zone 44
I_1_I_1_I Zone 45
I_1_I_1_I Zone 46
I_1_I_1_I Zone 47
I_1_I_1_I Zone 48
I_0_I_0_I Zone 41
I_0_I_0_I Zone 42
I_0_I_0_I Zone 43
I_0_I_0_I Zone 44
I_0_I_0_I Zone 45
I_0_I_0_I Zone 46
I_0_I_0_I Zone 47
I_0_I_0_I Zone 48
*68 Restore/Trouble Codes Zones 33 to 48
I_0_I_0_I Zone Restore
I_0_I_0_I Zone Trouble
I_0_I_0_I Zone Trouble Restore
I_0_I_0_I Zone Bypass
I_0_I_0_I Zone Bypass Restore
*69 Alarm Report Codes Zones 49 to 56 *70 – Extended Report Codes Zones 49 to 56
I_1_I_1_I Zone 49
I_1_I_1_I Zone 50
I_1_I_1_I Zone 51
I_1_I_1_I Zone 52
I_1_I_1_I Zone 53
I_1_I_1_I Zone 54
I_1_I_1_I Zone 55
I_1_I_1_I Zone 56
I_0_I_0_I Zone 49
I_0_I_0_I Zone 50
I_0_I_0_I Zone 51
I_0_I_0_I Zone 52
I_0_I_0_I Zone 53
I_0_I_0_I Zone 54
I_0_I_0_I Zone 55
I_0_I_0_I Zone 56
*71 Alarm Report Codes Zones 57 to 64 *72 Extended Report Codes Zones 57 to 64
I_1_I_1_I Zone 57
I_1_I_1_I Zone 58
I_1_I_1_I Zone 59
I_1_I_1_I Zone 60
I_1_I_1_I Zone 61
I_1_I_1_I Zone 62
I_1_I_1_I Zone 63
I_1_I_1_I Zone 64
I_0_I_0_I Zone 57
I_0_I_0_I Zone 58
I_0_I_0_I Zone 59
I_0_I_0_I Zone 60
I_0_I_0_I Zone 61
I_0_I_0_I Zone 62
I_0_I_0_I Zone 63
I_0_I_0_I Zone 64
*73 Restore/Trouble Codes Zones 49 to 64
I_0_I_0_I Zone Restore
I_0_I_0_I Zone Trouble
I_0_I_0_I Zone Trouble Restore
I_0_I_0_I Zone Bypass
I_0_I_0_I Zone Bypass Restore
*74 Alarm Report for RF RCVR & Panics *75 Extended Report for RF RCVR & Panics
I_0_I_0_I Zone 81 4210 Supervisory
I_0_I_0_I Not Used
I_0_I_0_I Zone 83 4219 Temp Module
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Zone 88 Rcvr not hearing Trans
I_0_I_0_I Zone 81
I_0_I_0_I Not Used
I_0_I_0_I Zone 83
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Zone 88
*76 Alarm Report for RF RCVR & Panics *77 Extended Report for RF RCVR & Panics
I_0_I_0_I Zone 89 Rcvr not Respo/Bad Con
I_0_I_0_I Zone 90 Recvr not hearing Trans
I_0_I_0_I Zone 91 Recvr not Resp/ Bad Con
I_1_I_1_I Zone 92 Duress
I_0_I_0_I Zone 97 Polling Loop Short
I_1_I_1_I Zone 95 1 & * / A Fire Panic Key
I_1_I_1_I Zone 96 3 & # / C Med Panic Key
I_1_I_1_I Zone 99 * & # / B Police Panic Key
I_0_I_0_I Zone 89
I_0_I_0_I Zone 90
I_0_I_0_I Zone 91
I_0_I_0_I Duress
I_0_I_0_I Zone 97
I_0_I_0_I Zone 95
I_0_I_0_I Zone 96
I_0_I_0_I Zone 99
*78 Restore/Trouble for RF RCVR & Panics
I_0_I_0_I Zone Restore
I_0_I_0_I Zone Trouble
I_0_I_0_I Zone Trouble Restore
I_0_I_0_I Zone Bypass
I_0_I_0_I Zone Bypass Restore
*79 Zone Restore Enable Zones 1 -8 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I 0 = Disable
*80 Zone Restore Enable Zones 9 -10 I_0_I_0_I 1 = Enable
*81 System Non-Alarm Codes *82 System Non-Alarm Codes 2nd Digit
I_0_I_0_I Close
I_0_I_0_I Open
I_1_I_1_I Low Battery
I_0_I_0_I Low Battery Restore
I_1_I_1_I AC Loss
I_0_I_0_I AC Loss Restore
I_0_I_0_I Test
I_0_I_0_I Power
I_1_I_1_I Cancel
I_0_I_0_I Program Tamper
I_0_I_0_I Close
I_0_I_0_I Open
I_0_I_0_I Low Battery
I_0_I_0_I Low Battery Rest
I_0_I_0_I AC Loss
I_0_I_0_I AC Loss Rest
I_0_I_0_I Test
I_0_I_0_I Power
I_0_I_0_I Cancel
I_0_I_0_I Program Tamper
*83 First Test Report Time I_0_I_0_I_0_I_2_I_0_I_0_I
*84 Swinger Shutdown I_0_I_4_I 00 to 15 Alarms
*85 *86 Not Used
*87 Entry Warning I_0_I 1 = Continuous
0 = 3 beeps
*88 Burg Alarm Comm Delay I_0_I 0 = No Delay
1 = 16 seconds
*89 Not Used
*90 2nd Account Number I__I__I__I__I (Do not Program)
*93 5137 LCD Keypad Programming

*97 Default Panel (No Value needed, keypad beeps and defaults panel)

For Upper Level Programming press *94
To go to an Upper Level Location press *00 to *01 etc
To return to lower programming press *99
Upper Level Programming

1*00 Open/Close Report Enable I_0_I User 17
I_0_I User 18
I_0_I User 19
I_0_I User 20
I_0_I User 21
I_0_I User 22
I_0_I User 23 to 70
0 = No
1 = Yes
1*01 Zone Types for Zones 28 to 89 I_?_I_?_I Zone 28
I_?_I_?_I Zone 29
I_?_I_?_I Zone 30
I_?_I_?_I Zone 31
I_?_I_?_I Zone 32
00 = Disabled
01 = Entry/Exit 1
02 = Entry/Exit 2
03 = Instant
04 = Interior
05 = Day Zone
06 = Holdup
07 = Police
08 = Auxiliary/Medical
09 = Fire
10 = Interior Delay
1*02 Zone Types for Zones 22 to 40 I_?_I_?_I Zone 33
I_?_I_?_I Zone 34
I_?_I_?_I Zone 35
I_?_I_?_I Zone 36
I_?_I_?_I Zone 37
I_?_I_?_I Zone 38
I_?_I_?_I Zone 39
I_?_I_?_I Zone 40
1*03 Zone Types for Zones 41 to 48 I_?_I_?_I Zone 41
I_?_I_?_I Zone 42
I_?_I_?_I Zone 43
I_?_I_?_I Zone 44
I_?_I_?_I Zone 45
I_?_I_?_I Zone 46
I_?_I_?_I Zone 47
I_?_I_?_I Zone 48
1*04 Zone Types for Zones 49 to 56 I_?_I_?_I Zone 49
I_?_I_?_I Zone 50
I_?_I_?_I Zone 51
I_?_I_?_I Zone 52
I_?_I_?_I Zone 53
I_?_I_?_I Zone 54
I_?_I_?_I Zone 55
I_?_I_?_I Zone 56
1*05 Zone Types for Zones 57 to 64 I_?_I_?_I Zone 57
I_?_I_?_I Zone 58
I_?_I_?_I Zone 59
I_?_I_?_I Zone 60
I_?_I_?_I Zone 61
I_?_I_?_I Zone 62
I_?_I_?_I Zone 63
I_?_I_?_I Zone 64
1*06 Not Used
1*07 Not Used
1*08 Receiver & Voice Module Superv I_0_I_0_I Zone 81 4219 Not Communicating
I_0_I_0_I Not Used
I_0_I_0_I Zone 83 4219 Tamper
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Not Used
I_0_I_0_I Zone 88 2nd Receiver
1*09 1st & 2nd Receiver Troubles I_?_I_?_I Zone 89 2nd Receiver
I_?_I_?_I Zone 90 1st Receiver
I_?_I_?_I Zone 91 1st Receiver
1*10 Right Loop Zones 33 to 40 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I 0 = No
1*11 Right Loop Zones 41 to 48 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I 1 = Yes
1*12 Right Loop Zones 49 to 56 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*13 Right Loop Zones 57 to 64 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*18 Enable Wireless Zones 1 to 8 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*19 Enable Wireless Zones 9 to 16 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*20 Enable Wireless Zones 17 to 24 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*21 Enable Wireless Zones 25 to 32 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*22 Enable Wireless Zones 33 to 40 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*23 Enable Wireless Zones 41 to 48 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*24 Enable Wireless Zones 49 to 56 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*25 Enable Wireless Zones 57 to 63 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
1*26 First RF Receiver Select I_0_I 0 = No
1 = Yes
1*27 Second RF Receiver Select I_0_I 0 = No
1 = Yes
1*28 RF Low Battery Sound I_0_I 0 = When Disarmed
1 = Immediate
1*29 RF Low Battery Report Enable I_1_I 0 = Disable
1 = Enable
1*30 RF RCVR Check-In Interval I_0_I_6_I 00 = Disabled
02 -15 x2 Hours
1*31 RF Transmitter Check in Interval I_1_I_2_I 00 = Disabled
02 to 15×2 Hours
1*32 RF Receiver Type I_?_I 0 = None or 4280 Receiver
1 = 4281 Receiver
1*33 Touch-Tone W/Rotary Backup I_1_I 0 = No
1 = Yes
1*34 Comm Split Report Selection I_1_I 0 = No
1 = Alarms Primary
2 = O/C Secondary
1*35 – 1*39 – Not Used
1*40 Armed Stay Report 1st Digit I_0_I_0_I 00 = No Report
1*41 Armed Stay Report 2nd Digit I_0_I_0_I 00 = No Report
1*44 RF Keypad Tamper Detect I_0_I 0 = No
1 = Yes
1*45 Enable Exit Beeps I_1_I 0 = No
1 = Yes
1*46 Aux Output Enable I_0_I 0 = Ground Start
1 = O/C Trigger Term 9
2 = Not Used
3 = Zone 1 EOLR
1*47 Chime on External Sounder I_0_I 0 = Disable
1 = Enable
1*48 Wireless Keypad Disable I_0_I 0 = Disable
1 = Enable
1*49 Suppress Trouble Sound for RF I_1_I 0 = Disable
1 = Enable
1*50 Babysitter Code User 22 I_1_I 0 = Disable
1 = Enable
1*51 4281 House ID (5700 wireless) I_0_I_0_I 00 to 31
1*52 Cancel Report Restriction I_0_I 0 = Timeout
1 = None
1*53 Download Callback I_1_I 0 = Yes
1 = No Callback
1*54 High Security Mode I_0_I 0 = 4-digit Codes
1 = 6-digits
1*55 to 1*56 Not Used
1*57 Trigger Mode I_1_I (0, 1, 2, 3 See Manual)
1*68 4219 First Zone Number I_0_I_0_I (09 to 57, 00 = Disabled
Press *99 to return to regular Programming