Ademco 4120OEC Program

Enter Program 4120 + 8 + 0 + 0 (Display should show 00)
or Power down then back up and press * and # within 1 minute
(If exiting programming you can re-enter within 1 minute by pressing * & #)
Exit Program *99
Move to Location * + Location
View Location # + Location (Display will read off one digit at a time)
Hex Program 10 = A 11 = B 12 = C 13 = D 14 = 14 15 = F
Use Caution, this panel allows you into locations that are not on the program sheet!

*00 Installer Code I_4_I_1_I_2_I_0_I
*01 Master Code I__I__I__I__I
*02 Zones Types 1 to 8 I_?_I_?_I Zone 1
Smokes must use Zone 1 (2-wire only)
I_?_I_?_I Zone 2
I_?_I_?_I Zone 3
I_?_I_?_I Zone 4
I_?_I_?_I Zone 5
I_?_I_?_I Zone 6
I_?_I_?_I Zone 7
I_?_I_?_I Zone 8
00 = Disabled
01 = Entry/Exit
02 = Not Used
03 = Instant
04 = Interior
05 = Day Zone
06 = Holdup
07 = Police
08 = Medical
09 = Fire
*05 Panic Zone Types I_0_I_0_I Not Used
I_0_I_8_I 3 & #
I_0_I_7_I * & #
*08 NO/NC Sensors I_1_I Zone 1
I_1_I Zone 2
I_1_I Zone 3
I_1_I Zone 4
I_1_I Zone 5
I_1_I Zone 6
I_1_I Zone 7
I_1_I Zone 8
0 = Normally Closed
1 = Normally Open

(Use 0 if Smoke on Zone 1)

*09 Entry Delay I_0_I_3_I 00 to 15 x 15 seconds
*10 Exit Delay I_0_I_6_I 00 to 15 x 15 seconds
*13 Alarm Sounder Timeout I_0_I_4_I 00 to 15 x 2 minutes
*14 Zone 8 Response Time I_0_I 0 = 350ms
1 = 10ms
*21 No Fire Timeout I_0_I 0 = No
1 = Yes
*25 Disable Duress Express Fmt I_0_I 0 = No
1 = Yes
*27 Test Report Interval I_0_I 0 = Disabled
1 = 12 Hours
2 = 24 Hours
3 = 168 Hours (Week)
*29 Quick Arm I_1_I 0 = No
1 = Yes
*30 Touch Tone Dialing I_1_I 0 = Pulse Dial
1 = Touch Tone Dial
*31 PABX Code I__I__I__I__I
*32 Account Number I_0_I_?_I_0_I_?_I_0_I_?_I_0_I_?_I
(Account 1234 = 01 02 03 04) 10 = A, 11 = B, 12 = C, 13 = D, 14 = E, 15 = F
*33 Primary Phone (12 digits) I__I__I__I__I__I__I__I__I__I__I__I__I
End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause)
*34 Secondary Phone (12 digits) I_N_I_O_I_T_I__I_U_I_S_I_E_I_D_I__I__I__I__I
*35 Callback (12 digits) I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I__I
*36 CSID Download ID I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I
(This resets CSID to default of FFFFFFFF)
*40 Program Tamper Report I_0_I_0_I 00 to 15
*41 EOL Resistor on Zone 1 I_0_I 0 = EOL Supervision
1 = No EOL
*44 Ring Detect I_1_I_5_I 01 to 15 15 = Answer Machine Over-Ride
*46 Primary Format I_0_I 0 = Ademco Lo Speed
1 = Radionics
2 = 4/2 Ademco Express
*48 Secondary Format I_0_I 0 = Ademco Lo Speed
1 = Radionics
2 = 4/2 Ademco Express
*49 Checksum Verify I_0_I 0 = No
1 = Yes
*54 4-2 Format I_1_I 0 = No
1 = Yes
*55 Alarm Report I_1_I 0 = Standard
1 = Extended
*56 Restore Report I_1_I 0 = Standard
1 = Extended
*57 Bypass Report I_1_I 0 = Standard
1 = Extended
*58 Trouble Report I_1_I 0 = Standard
1 = Extended
*59 Open/Close Report I_1_I 0 = Standard
1 = Extended)
*60 Low Bat/AC Loss/Test I_1_I 0 = Standard
1 = Extended
*65 Zone Report Codes I_0_I_3_I Zone 1 (If Smoke use 01) (Sends 31, Smoke sends 11)
I_0_I_3_I Zone 2 (Sends 32)
I_0_I_3_I Zone 3 (Sends 33)
I_0_I_3_I Zone 4 (Sends 34)
I_0_I_3_I Zone 5 (Sends 35)
I_0_I_3_I Zone 6 (Sends 36)
I_0_I_3_I Zone 7 (Sends 37)
I_0_I_3_I Zone 8 (Sends 38)
*66 Panic Report Codes I_0_I_2_I Duress (Zone 9) (Sends 29)
I_0_I_4_I 3 & # (Zone A/Medical or Fire)(Sends 40)
I_0_I_2_I * & # (Zone B/Police) (Sends 2B)
*67 Non Alarm Report Codes I_0_I_7_I AC Loss 1st Digit
I_0_I_9_I AC Loss 2nd Digit (Sends 79)
I_0_I_7_I Trouble (Fire) (Sends 71)
I_0_I_9_I Trouble Restore (Fire) (Sends 9 followed by zone number)
I_0_I_0_I Bypass
I_0_I_0_I Bypass Restore
I_0_I_9_I Alarm/AC/Low Bat Restore (Sends 9 followed by zone number)
*68 Misc Report Codes I_0_I_0_I Openings (05 If needed)
I_0_I_0_I Closings (06 If needed)
I_0_I_7_I Low Battery
I_0_I_8_I Low Battery 2nd Digit (Sends 78)
I_1_I_4_I Test (Sends E0)
I_1_I_3_I Cancel (Sends D0)