Ademco 4111XMP Trouble

bF Long Range Radio trouble
NO AC AC Power Failure
BAT Panel Battery low
BAT 01 – 30 Zone has low battery
BAT 00 Low Remote Keypad battery
Check 01 – 30 Zone is not communicating with panel
Check 9 Wireless Receiver or Module failure (check sections 22, 24, 25)
Check 70 Supervised Bell Circuit trouble (Make sure *91 is 0 to prevent this)
D1 System is in wait mode, if remains system has an internal problem
System Busy System is in wait mode, if remains system has an internal problem
CA Alarm was canceled, this is not a system trouble
Canceled Alarm Alarm was canceled, this is not a system trouble
CC Panel is being downloaded by Tech Support
EA Exit Alarm, this is not a trouble, system was armed
and door wasn’t closed before Exit Delay expired
FC Fail to Communicate
E4 More wireless zones programmed than Low receiver capable of using
E8 More wireless zones programmed than Medium receiver capable of using
OC Open Circuit, bad keypad wire
Beep every
40 sec
System is in Test Mode (Press Code + 1 to exit)
Reset Smoke 4-digit code + 1 (OFF) twice to turn off siren and reset smoke
(If this does NOT reset smoke detector set for service, smoke is bad)
(If Wireless)
Smoke Batteries Remove old batteries, hold Smoke test button 30 seconds, add new batteries