Ademco 4111XMP Program
Enter Program |
4111 + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute |
|||
Move to Location | * + Location | |||
View Location | # + Location (Display will read off one digit at a time) | |||
Exit Program | 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00 | |||
Hex Program | Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 | |||
|
||||
*20 Installer Code | I_4_I_1_I_1_I_1_I | |||
*21 Quick Arm Enable | I_1_I |
0 = No 1 = Yes |
||
*22 RF System Type | I_?_I |
0 = None 1 = 5700 Wireless Sensors 2 = 5800 Wireless Sensors 4281L receiver adds 4 zones 4281M and 4281H add 8 zones |
||
Panel treats 5700 Wireless like Hardwire zones do not program like Wireless zones |
||||
*23 Force Bypass Enable | I_0_I |
0 = No 1 = Yes |
||
*24 RF House Code | I_0_I_0_I | 00 = Disabled, 01-31 | ||
If using old 5700 series wireless this must match sensor dip switches Also used with 5804BD keyfobs and 5827BD Keypads |
||||
*25 Output Relay Module | I_0_I |
0 = None 1 = 4219 Zone Expander 2 = 4229 Zone Expander 3 = 4204 Relay Module |
||
*28 Single Alarm Sounding/Zone | I_0_I |
0 = No 1 = Yes |
||
*29 Fire Sounder Timeout | I_1_I |
0 = Yes 1 = No Fire Timeout |
||
*30 Alarm Bell Timeout | I_2_I |
0 = None 1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
||
*38 Entry Delay | I_2_I |
1 = 20 seconds 2 = 30 seconds 3 = 45 seconds 4 = 60 seconds 5 = 90 seconds |
||
Exit Delay = Entry + 15 seconds | ||||
*39 Zone 3 Response to Open | I_0_I |
0 = 400ms 1 = 10ms |
||
*40 PABX Access Code | I__I__I__I__I | (If 9 is needed to dial add here) | ||
*41 Primary Phone (12 digits) End Phone Number with * |
I__I__I__I__I__I__I__I__I__I__I__I__I # + 11 = * # + 12 = # # + 13 = 2.5 second pause |
|||
*42 Secondary Phone | I__I__I__I__I__I__I__I__I__I__I__I__I | |||
*43 Partition 1 Account | I__I__I__I__I | |||
(Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15) | ||||
*43 Partition 1 Account | I__I__I__I__I | |||
*45 Phone System Select | I_1_I |
0 = Pulse Dialing 1 = DTMF Dialing 2 = Pulse Dialing, CS on Watts Line 3 = DTMF Dialing, CS on Watts Line |
||
*46 Report Format | I_7_I |
0 = 3/1, 4/1 Ademco L/S Standard 1 = 3/1, 4/1 Radionics Standard 2 = 4/2 Ademco L/S Standard 3 = 4/2 Radionics Standard 6 = 4/2 Ademco Express 7 = Contact ID 8 = 3/1, 4/1 Ademco L/S Expanded 9 = 3/1, 4/1 Radionics Expanded |
||
*47 Split/Dual Reporting | I_0_I | |||
To Primary Phone 0 = All Reports 1 = Alarms, Restore, Cancel 2 = All Reports except Open/Close, Test 3 = Alarms, Restore, Cancel 4 = All Reports except Open/Close, Test 5 = All Reports (Dual Reporting) |
To Secondary Phone Backup only All Other Reports Open/Close, Test All Reports All Reports All Reports |
|||
*48 15 Sec Burg Dial Delay | I_0_I |
0 = No 1 = Yes |
||
*49 Periodic Test Message | I_3_I |
0 = None 1 = 24 Hours 2 = Weekly 3 = Monthly |
||
*50 Sescoa/Radionics | I_0_I |
0 = No 1 = Yes |
||
*51 Confirmation of Arming Ding | I_0_I |
0 = No 1 = Yes 2 = Yes for RF Arming (Keyfobs) |
||
*52 Zone 3 Response | I_0_I |
0 = 400 ms 1 = 10 ms |
||
*56 Zone Assignments | ||||
Hardwired | Zones 01 to 06 | |||
4219/4229 Zone Expander | Zones 10 to 30 (depends on receiver capacity) | |||
Police Panic | Zone 07 | |||
Duress | Zone 92 | |||
Tamper | Zone 09 | |||
Wireless | Zones 10 to 22 | |||
Fire Panic | Zone 95 | |||
Medical Panic | Zone 96 | |||
1. Keypad displays “Zone Prog?” press 1 | ||||
2. “Enter Zn No.” enter which zone to program (01-87, 88-91, 95, 96, 97, 99) press * | ||||
3. Keypad will show summary zones programming, press * | ||||
4. “Zone Type?” enter type then * |
00 = Zone Disabled/Deleted 01 = Delay Zone 02 = Do not Use 03 = Perimeter/Instant 04 = Interior Follower/Motions 05 = Trouble by Day/Alarm by Night 06 = 24 hour Silent/Holdup 07 = 24 hour Police Panic 08 = 24 hour Aux/Medical 09 = Fire 10 = Interior Delay 20 = Arm-Stay (RF only) 21 = Arm-Away (RF only) 22 = Disarm (RF only) 23 = No Alarm Response |
|||
5.”Partition?” | 1 for Partition 1 or 2 for Partition 2 then * | |||
6. “Report Code?” enter 10 then * | ||||
7. “Input Device?” enter device then * |
1 = for Hardwired
2 = Not Used 3 = for Supervised RF 4 = for Un-Supervised RF 5 = RF Button Type (Keyfobs/Panics etc) 6 = Serial number polling loop devices 7 = Dip Switch polling loop devices 8 = Right Loop of DIP switch type device (4190 expander) |
|||
(New versions may go to step 9 to learn sensor then program Loop Number) | ||||
8. Cursor should flash above the loop number “LP#”, Enter 1 to 4 depending on sensor | ||||
Door Switch |
– Loop 1 = External Sensor Connector – Loop 2 = Internal Reed Switch |
|||
Glassbreak | – Loop 1 | |||
Smoke Detectors | – Loop 1 | |||
Motions | – Loop 1 | |||
Keyfobs |
(Each button counts as 1 zone)
– Loop 1 = Bottom Right Button – Loop 2 = Top Right Button – Loop 3 = Top Left Button – Loop 4 = Bottom Left Button |
|||
9. “Learn Sensor Y/N?” press 1 and either enter serial number or trip sensor twice | ||||
10. “Alpha Program?” press 0 if not programming Alpha descriptions | ||||
11. ” Keypad will show either new summary for zone or “Enter zone number” | ||||
12. If finished programming enter 00 at “Enter zone no” to return to normal programming | ||||
*60 Trouble Report Code | I_1_I_0_I | |||
*61 Bypass Report Code | I_0_I_0_I | |||
*62 AC Loss Report Code | I_1_I_0_I | |||
*63 Low Bat Report Code | I_1_I_0_I | |||
*64 Test Report Code | I_0_I_0_I | |||
*65 Open Report Code Per Partition | I_0_I Partition 1 | |||
I_0_I Partition 2 | ||||
*66Close Report Code Per Partition | I_0_I Partition 1 | |||
I_0_I Partition 2 | ||||
*67 RF Xmtr Low Bat | I_0_I_0_I | |||
*68 Cancel Report Code | I_1_I_0_I | |||
*69 Group Restores for Trouble | I_0_I_0_I | |||
*70 Alarm Restore Code | I_0_I | |||
*71 Trouble Restore Code | I_0_I_0_I | |||
*72 Bypass Restore Code | I_0_I_0_I | |||
*73 AC Restore Code | I_0_I_0_I | |||
*74 Low Bat Rest Code | I_0_I_0_I | |||
*75 RF Low Bat Rest Code | I_0_I_0_I | |||
*80 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||
*81 Output Relays (Usually program only if 4204 Relay is enabled in *25) | ||||
*82 Custom Alpha Editing (Do not Program) | ||||
*83 Sequential Mode (Alternate way of programming sensors, not used) | ||||
*94 Download Phone Number | I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I__I | |||
*95 Ring Count | I_# 15_I 0 to #15 | #15 = Answer Machine | ||
*96 Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s) | ||||
*97 Default Panel (No Value needed, keypad will beep and default panel) | ||||
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) | ||||
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) |