Ademco 4111XMP Program

Enter Program 4111 + 8 + 0 + 0 (Display should show 20)
or Power down then back up and press * and # within 1 minute
Move to Location * + Location
View Location # + Location (Display will read off one digit at a time)
Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00
Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

*20 Installer Code I_4_I_1_I_1_I_1_I
*21 Quick Arm Enable I_1_I 0 = No
1 = Yes
*22 RF System Type I_?_I 0 = None
1 = 5700 Wireless Sensors
2 = 5800 Wireless Sensors
4281L receiver adds 4 zones
4281M and 4281H add 8 zones
Panel treats 5700 Wireless like Hardwire zones
do not program like Wireless zones
*23 Force Bypass Enable I_0_I 0 = No
1 = Yes
*24 RF House Code I_0_I_0_I 00 = Disabled, 01-31
If using old 5700 series wireless this must match sensor dip switches
Also used with 5804BD keyfobs and 5827BD Keypads
*25 Output Relay Module I_0_I 0 = None
1 = 4219 Zone Expander
2 = 4229 Zone Expander
3 = 4204 Relay Module
*28 Single Alarm Sounding/Zone I_0_I 0 = No
1 = Yes
*29 Fire Sounder Timeout I_1_I 0 = Yes
1 = No Fire Timeout
*30 Alarm Bell Timeout I_2_I 0 = None
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
4 = 16 minutes
*38 Entry Delay I_2_I 1 = 20 seconds
2 = 30 seconds
3 = 45 seconds
4 = 60 seconds
5 = 90 seconds
Exit Delay = Entry + 15 seconds
*39 Zone 3 Response to Open I_0_I 0 = 400ms
1 = 10ms
*40 PABX Access Code I__I__I__I__I (If 9 is needed to dial add here)
*41 Primary Phone (12 digits)
End Phone Number with *
I__I__I__I__I__I__I__I__I__I__I__I__I
# + 11 = *   # + 12 = # # + 13 = 2.5 second pause
*42 Secondary Phone I__I__I__I__I__I__I__I__I__I__I__I__I
*43 Partition 1 Account I__I__I__I__I
(Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15)
*43 Partition 1 Account I__I__I__I__I
*45 Phone System Select I_1_I 0 = Pulse Dialing
1 = DTMF Dialing
2 = Pulse Dialing, CS on Watts Line
3 = DTMF Dialing, CS on Watts Line
*46 Report Format I_7_I 0 = 3/1, 4/1 Ademco L/S Standard
1 = 3/1, 4/1 Radionics Standard
2 = 4/2 Ademco L/S Standard
3 = 4/2 Radionics Standard
6 = 4/2 Ademco Express
7 = Contact ID
8 = 3/1, 4/1 Ademco L/S Expanded
9 = 3/1, 4/1 Radionics Expanded
*47 Split/Dual Reporting I_0_I
To Primary Phone
0 = All Reports
1 = Alarms, Restore, Cancel
2 = All Reports except Open/Close, Test
3 = Alarms, Restore, Cancel
4 = All Reports except Open/Close, Test
5 = All Reports (Dual Reporting)
To Secondary Phone
Backup only
All Other Reports
Open/Close, Test
All Reports
All Reports
All Reports
*48 15 Sec Burg Dial Delay I_0_I 0 = No
1 = Yes
*49 Periodic Test Message I_3_I 0 = None
1 = 24 Hours
2 = Weekly
3 = Monthly
*50 Sescoa/Radionics I_0_I 0 = No
1 = Yes
*51 Confirmation of Arming Ding I_0_I 0 = No
1 = Yes
2 = Yes for RF Arming (Keyfobs)
*52 Zone 3 Response I_0_I 0 = 400 ms
1 = 10 ms
*56 Zone Assignments
Hardwired Zones 01 to 06
4219/4229 Zone Expander Zones 10 to 30 (depends on receiver capacity)
Police Panic Zone 07
Duress Zone 92
Tamper Zone 09
Wireless Zones 10 to 22
Fire Panic Zone 95
Medical Panic Zone 96
1. Keypad displays “Zone Prog?” press 1
2. “Enter Zn No.” enter which zone to program (01-87, 88-91, 95, 96, 97, 99) press *
3. Keypad will show summary zones programming, press *
4. “Zone Type?” enter type then * 00 = Zone Disabled/Deleted
01 = Delay Zone

02 = Do not Use

03 = Perimeter/Instant

04 = Interior Follower/Motions

05 = Trouble by Day/Alarm by Night

06 = 24 hour Silent/Holdup

07 = 24 hour Police Panic

08 = 24 hour Aux/Medical

09 = Fire

10 = Interior Delay

20 = Arm-Stay (RF only)

21 = Arm-Away (RF only)

22 = Disarm (RF only)

23 = No Alarm Response

5.”Partition?” 1 for Partition 1 or 2 for Partition 2 then *
6. “Report Code?” enter 10 then *
7. “Input Device?” enter device then * 1 = for Hardwired

2 = Not Used

3 = for Supervised RF

4 = for Un-Supervised RF

5 = RF Button Type (Keyfobs/Panics etc)

6 = Serial number polling loop devices

7 = Dip Switch polling loop devices

8 = Right Loop of DIP switch type device (4190 expander)

(New versions may go to step 9 to learn sensor then program Loop Number)
8. Cursor should flash above the loop number “LP#”, Enter 1 to 4 depending on sensor
Door Switch – Loop 1 = External Sensor Connector
– Loop 2 = Internal Reed Switch
Glassbreak – Loop 1
Smoke Detectors – Loop 1
Motions – Loop 1
Keyfobs (Each button counts as 1 zone)

– Loop 1 = Bottom Right Button

– Loop 2 = Top Right Button

– Loop 3 = Top Left Button

– Loop 4 = Bottom Left Button

9. “Learn Sensor Y/N?” press 1 and either enter serial number or trip sensor twice
10. “Alpha Program?” press 0 if not programming Alpha descriptions
11. ” Keypad will show either new summary for zone or “Enter zone number”
12. If finished programming enter 00 at “Enter zone no” to return to normal programming
*60 Trouble Report Code I_1_I_0_I
*61 Bypass Report Code I_0_I_0_I
*62 AC Loss Report Code I_1_I_0_I
*63 Low Bat Report Code I_1_I_0_I
*64 Test Report Code I_0_I_0_I
*65 Open Report Code Per Partition I_0_I Partition 1
I_0_I Partition 2
*66Close Report Code Per Partition I_0_I Partition 1
I_0_I Partition 2
*67 RF Xmtr Low Bat I_0_I_0_I
*68 Cancel Report Code I_1_I_0_I
*69 Group Restores for Trouble I_0_I_0_I
*70 Alarm Restore Code I_0_I
*71 Trouble Restore Code I_0_I_0_I
*72 Bypass Restore Code I_0_I_0_I
*73 AC Restore Code I_0_I_0_I
*74 Low Bat Rest Code I_0_I_0_I
*75 RF Low Bat Rest Code I_0_I_0_I
*80 Output Relays (Usually program only if 4204 Relay is enabled in *25)
*81 Output Relays (Usually program only if 4204 Relay is enabled in *25)
*82 Custom Alpha Editing (Do not Program)
*83 Sequential Mode (Alternate way of programming sensors, not used)
*94 Download Phone Number I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I__I
*95 Ring Count I_# 15_I 0 to #15 #15 = Answer Machine
*96 Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s)
*97 Default Panel (No Value needed, keypad will beep and default panel)
*98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0)
*99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0)