Ademco 4110XM Program
Enter Program |
1. Master Code + 8 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) |
|
Move to Location | * + Location | |
View Location | # + Location (Display will read off one digit at a time) | |
Exit Program | 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 0 | |
Hex Program | Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 |
*20 | Master Code | I_ _I_ _I_ _I_ _I | (Default is 4110) | ||
*21 | Quick Arm Enable | I_1_I |
0 = No 1 = Yes |
||
*22 | Keyswitch Enable | I_0_I |
0 = No 1 = Yes |
||
*23 | Force Bypass Enable | I_0_I |
0 = No 1 = Yes |
||
*24 | RF House Code | I_0_I_0_I |
00 = Disabled, 01 to 31 (must match wireless sensor House Code) |
||
*27 | Audible Exit Warning | I_1_I |
0 = No 1 = Yes |
||
*28 | Confirmation of Arming Ding | I_0_I |
0 = No 1 = Yes |
||
*29 | Fire Sounder No Timeout | I_1_I |
0 = No 1 = Yes |
||
*30 | Alarm Bell Timeout | I_2_I |
1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16 minutes |
||
*31 | Zone 1 Definition | I_?_I |
(Smoke Detectors MUST use Zone 5) 0 = Zone Disabled 1 = Entry/Exit 2 = Not Used 3 = Instant/Perimeter 4 = Interior/PIR 5 = Trouble by Day 6 = 24 hr Silent (Holdup) 7 = 24 hr Audible (Police Panic) 8 = 24 hr Auxiliary (Medical) 9 = Fire without timeout (Smokes) 10 = Interior w/Delay (new 4110XM’s only) |
||
*32 | Zone 2 Definition | I_?_I | |||
*33 | Zone 3 Definition | I_?_I | |||
*34 | Zone 4 Definition | I_?_I | |||
*35 | Zone 5 Definition | I_?_I | |||
*36 | Zone 6 Definition | I_?_I | |||
*37 | Zone 7 Definition (Panic * & #) | I_7_I | |||
*38 | Entry Delay Exit Delay = Entry + 15 seconds |
I_2_I |
1 = 20 seconds 2 = 30 seconds 3 = 45 seconds 4 = 60 seconds 5 = 90 seconds |
||
*39 | Zone 3 Response to open | I_0_I |
0 = 400ms 1 = 10ms |
||
*40 | PABX Access Code | I_ _I_ _I_ _I_ _I | (If 9 is needed to dial add here) | ||
*41 |
Primary Phone (12 digits) End Phone Number with * |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I # + 11 = * # + 12 = # # + 13 = 2.5 second pause |
|||
*42 | Secondary Phone |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Pager only available on VERY new 4110XM’s, pager will not work if Account starts with 0) |
|||
*43 | Subscriber Account | I_ _I_ _I_ _I_ _I | |||
*44 | Report Format | I_7_I |
0 = 3/1, 4/1 Ademco L/S Standard 1 = 3/1, 4/1 Radionics Standard 2 = 4/2 Ademco L/S Standard 3 = 4/2 Radionics Standard 6 = 4/2 Ademco Express 7 = Contact ID 8 = 3/1, 4/1 Ademco L/S Expanded 9 = 3/1, 4/1 Radionics Expanded |
||
*45 | Phone Sys Select | I_1_I |
0 = Pulse Dial 1 = DTMF Dial 2 = Pulse Dial (Watts Line) 3 = DTMF Dial (Watts Line) |
||
*46 | Sescoa/Radionics Select | I_0_I |
0 = Radionics 1 = Sescoa |
||
*47 | 15 Sec Burg Dial Delay | I_0_I |
0 = No 1 = Yes |
||
*48 | Periodic Test Message | I_0_I |
0 = None 1 = 24 Hours 2 = Weekly |
||
*49 | Split/Dual Reporting | I_0_I | |||
|
|||||
*50 | Keypad Medical/Fire |
I_1_I 1 & * I_1_I 3 & # |
(Silent, sends 95, use as Medical Panic) (Audible, sends 96, use as Fire Panic) |
||
*51 | Zone 1 Report Code | I_1_I_0_I | |||
*52 | Zone 2 Report Code | I_1_I_0_I | |||
*53 | Zone 3 Report Code | I_1_I_0_I | |||
*54 | Zone 4 Report Code | I_1_I_0_I | |||
*55 | Zone 5 Report Code | I_1_I_0_I | |||
*56 | Zone 6 Report Code | I_1_I_0_I | |||
*57 | Zone 7 Police Panic Report Code | I_1_I_0_I | |||
*58 | Zone 8 Duress Report Code | I_1_I_0_I | |||
*59 | Zone 9 Receiver Fail Report Code | I_0_I_0_I | |||
*60 | Trouble Report Code | I_1_I_0_I | |||
*61 | Bypass Report Code | I_0_I_0_I | |||
*62 | AC Loss Report Code | I_1_I_0_I | |||
*63 | Low Bat Report Code | I_1_I_0_I | |||
*64 | Test Report Code | I_1_I_0_I | |||
*65 | Open Report Code | I_0_I | |||
*66 | Close Report Code | I_0_I | |||
*67 | RF Xmtr Low Bat | I_0_I_0_I | |||
*68 | Cancel Report Code | I_1_I_0_I | |||
*69 | Group Restores Trouble/Bypass | I_0_I | |||
*70 | Alarm Restore Code | I_0_I | |||
*71 | Trouble Restore Code | I_0_I_0_I | |||
*72 | Bypass Restore Code | I_0_I_0_I | |||
*73 | AC Restore Code | I_0_I_0_I | |||
*74 | Low Bat Rest Code | I_0_I_0_I | |||
*75 | RF Low Bat Restore Code | I_0_I_0_I | |||
|
|||||
Wireless Zone Programming *76 to *79 only available with 4281L (Low) Receivers *76 to *83 only available with 4281M (Medium) or 4281 (High) Receivers |
|||||
|
|||||
Zone defines type of sensor |
Zone 10 to 13 = Delay zone Zone 14 to 29 = Instant Zone 30 to 47 = Interior/PIR Zone 48 to 55 = Fire Zone 56 to 61 = Day Zone Zone 62 = 24 hr Audible Zone 63 = Programmed in *92 |
||||
*76 | 1st Wireless Zone Definition |
I_?_I_?_I I_1_I_0_I |
Zone Number Report Code |
||
*77 | 2nd Wireless Zone |
I_?_I_?_I I_1_I_0_I |
Zone Number Report Code |
||
*78 | 3rd Wireless Zone |
I_?_I_?_I I_1_I_0_I |
Zone Number Report Code |
||
*79 | 4th Wireless Zone |
I_?_I_?_I I_1_I_0_I |
Zone Number Report Code |
||
*80 | 5th Wireless Zone |
I_?_I_?_I I_1_I_0_I |
Zone Number Report Code |
||
*81 | 6th Wireless Zone |
I_?_I_?_I I_1_I_0_I |
Zone Number Report Code |
||
*82 | 7th Wireless Zone |
I_?_I_?_I I_1_I_0_I |
Zone Number Report Code |
||
*83 | 8th Wireless Zone |
I_?_I_?_I I_1_I_0_I |
Zone Number Report Code |
||
*92 | Zone Response 63 | I_0_I | 0, 6, 7, 8, 9 only | ||
*93 | Reports Per Armed Period | I_0_I |
0 = 10 Reports per Arm period 1 = Unlimited |
||
*94 | Download Phone Number | I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I___I | |||
*95 | Ring Count | I_#15_I | 0 to #15 #15 = Answer Machine | ||
*96 | Reinitialize Download (No Value needed, keypad will just beep and reset CSID and account to all F’s) | ||||
*97 | Default Panel (No Value needed, keypad will beep and default panel) | ||||
*98 | Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) | ||||
*99 | Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) |