Ademco 4110XM Basics

Zones above 10 are Wireless
Zones 6 Hardwired, 8 Wireless
Battery 12 volt rechargeable Gel-Cell inside main panel
AC Transformer is 16.5 volts, screwed into outlet somewhere in house
Wireless 5700 series Wireless
all use 9-volt Alkaline
Downloadable Yes
Event Log None
Panic Buttons
Police Panic – * and #
Medical Panic – 1 and *
Fire Panic – 3 and #
Status Press * if keypad shows NOT READY to view open zones
Arm AWAY 4-digit code + 2 (AWAY)
Arm STAY 4-digit code + 3 (STAY)
Instant Arm 4 digit code + 7 (INSTANT)
Max Arming 4-digit code + 4 (MAX), arms everything including motions instant
Quick-Arm (If Enabled) Press # + 2 for AWAY, # + 3 for STAY
Disarm 4 digit code + 1 (OFF)
Silence Alarm 4 digit code + 1 (OFF) twice to turn off siren and reset display
Bypass 4-digit code + 6 (BYPASS) + zone (01, 02 etc), BYPASS and zone should display
Alarm Memory Last alarms only shows until system disarmed for the second time
Test Sensors 4-Digit Code + 5 (TEST)
Keypad will beep every 3 minutes
Open sensors and keypad will sound
End test with 4-digit Code + 1 (OFF) key
(Wireless motions require no movement for 4 minutes prior to testing)
Reset Smoke 4-digit code + 1 (OFF) twice to turn off siren and reset smoke
(If this does NOT reset smoke detector set for service, smoke is bad)
Door Chimes 4-digit code + 9 (CHIME) CHIME should appear on keypad display
Pager Signals Only available on really new 4110XM’s
Alarms Account + 1911 + 3 digit Zone
Openings Account + 1001 + 3 digit User
Closings Account + 1002 + 3 digit User
Trouble Account + 1811 + 3 digit Zone