Ademco 4110DL Trouble
bF | Long Range Radio trouble |
NO AC | AC Power Failure |
BAT | Panel Battery Low |
Check 01 to 06 | Zone is not communicating with panel, may be bad resistor |
Check 9 | Tamper trouble |
D1 | System is in wait mode, system may have an internal problem |
System Busy | System is in wait mode, system may have an internal problem |
CA | Alarm was canceled, this is not a trouble |
Canceled Alarm | Alarm was canceled, this is not a trouble |
CC | Panel is being downloaded by Tech Support |
EA |
Exit Alarm, this is not a trouble, customer armed system then left and didn’t close door before delay expired |
FC | Fail to Communicate |
OC | Open Circuit, bad keypad wire |
Beep every 40 sec | System is in Test Mode (Press Code + 1 to exit) |
Smoke Detector |
4-digit Code + 1 (OFF) twice to turn off siren and reset Smoke Detector (If this does not work power down system, Smoke Detector is bad) |