Ademco 4110DL Basics

Zones 6 Hardwired
Battery 12 volt rechargeable Gel-Cell inside main panel
AC Transformer is 16.5 volts, screwed into outlet somewhere in house
Wireless No
Downloadable Yes, cannot change audible exit delay location
Event Log None
Panic Buttons
Police Panic – * and #
Medical Panic – 1 and *
Fire Panic – 3 and #
Status Press * if keypad shows NOT READY to view open zones
Arm AWAY 4-digit code + 2 (AWAY)
Arm STAY 4-digit code + 3 (STAY)
Instant Arm 4-digit code + 7 (INSTANT)
Max Arming 4-digit code + 4 (MAX), arms everything including motions instant
Quick-Arm (If Enabled) Press # + 2 for AWAY, # + 3 for STAY
Disarm 4 digit code + 1 (OFF)
Silence Alarm 4 digit code + 1 (OFF) twice to turn off siren and reset display
Bypass 4-digit code + 6 (BYPASS) + zone (01, 02 etc), BYPASS and zone should display
Alarm Memory Last alarms only shows until system disarmed for the second time
Test Sensors 4-Digit Code + 5 (TEST)
Keypad will beep every 3 minutes
Open sensors and keypad will sound
End test with 4-digit Code + 1 (OFF) key
Reset Smoke 4-digit code + 1 (OFF) twice to turn off siren and reset smoke
(If this does NOT reset smoke detector set for service, smoke is bad)
Door Chimes 4-digit code + 9 (CHIME) CHIME should appear on keypad display
Pager Signals Only available on really new 4110DL
Alarms Account + 1911 + 3 digit Zone
Openings Account + 1001 + 3 digit User
Closings Account + 1002 + 3 digit User
Trouble Account + 1811 + 3 digit Zone