Ademco 320P1 Trouble

bF Long Range Radio failure (Cell backup)
C5 Need to set clock –
System must be disarmed

Date and Time To program without an Alpha Keypad
Installer or Master code + # + 6 + 3 + *
Enter the 2 digit hour
Enter the 2 digit minute
Press 1 for PM or Press 2 for AM
Enter the 2 digit year
Enter the 2 digit month
Enter the 2 digit day
Press * to exit (# to backup if incorrect entry made)
Date and Time To program with an Alpha Keypad
Installer or Master code + # + 6 + 3
System will display current time
* to enter the correct time
Enter the 2 digit hour
Enter the 2 digit minute
Press 1 for PM or Press 2 for AM
Enter the 2 digit year
Enter the 2 digit month
Enter the 2 digit day
Press * to exit (# to backup if incorrect entry made)
Check 91 Generic trouble display
Check 100 Wireless Receiver failure or keypad tamper
Check 103 Long Range Radio failure (Cell backup)
Check 104 4285 or 4286 Voice Module failure
Check 107 4219/4229 Hardwired zone expansion module failure (Zones 9-16)
Check 108 4219/4229 Hardwired zone expansion module failure (Zones 17-24)
Check 112 4204 Relay Module failure (Module 1)
Check 113 4204 Relay Module failure (Module 2)
Check 116 – 123 Keypad failure. Last 2 digits are the address. (Example, Check 116 is a failure on address 16)
Check 128 5800TM Module failure
NO AC AC Power Failure
BAT Panel Battery Low
BAT xxx Wireless zone low battery (where xxx is the zone number)
LB Keyfob Low battery for Locally programmed Keyfob
Check 01 to 34 Zone is not communicating with panel
Check 49 to 56 Keyfobs are programmed incorrectly
D1 System is in wait mode, system may have an internal problem
System Busy System is in wait mode, system may have an internal problem
CA Alarm was canceled, this is not a trouble
Canceled Alarm Alarm was canceled, this is not a trouble
CC Panel is being downloaded by Tech Support
Modem Comm Panel is being downloaded by Tech Support
94 Telephone Line Failure
Telco Fault Telephone Line Failure
70 Siren supervision failure
90 RF Jam detected
00 Bat Wireless keypad low battery
Cd Phone test okay
dO Dialer off
dd Walk test is active (Code + 50 to enter / Code + 1 to exit)
dC Download complete
dF Download failed
E4 or E8 More zones were programmed than wireless receiver is capable of using.
Alarm xxx Zone is or was in alarm where xxx is the zone number
Fault xxx Zone is faulted where xxx is the zone number
Check xxx Zone is not communicating with the panel where xxx is the zone number
EA Exit Alarm, this is not a trouble, customer armed system
then left and didn’t close door before delay expired
FC Fail to Communicate
OC Open Circuit, bad keypad wire
Beep every
40 sec

System is in Test Mode (Press Code + 1 to exit)