Ademco 320P1 Trouble
bF | Long Range Radio failure (Cell backup) | ||||
C5 |
Need to set clock – System must be disarmed
|
||||
Check 91 | Generic trouble display | ||||
Check 100 | Wireless Receiver failure or keypad tamper | ||||
Check 103 | Long Range Radio failure (Cell backup) | ||||
Check 104 | 4285 or 4286 Voice Module failure | ||||
Check 107 | 4219/4229 Hardwired zone expansion module failure (Zones 9-16) | ||||
Check 108 | 4219/4229 Hardwired zone expansion module failure (Zones 17-24) | ||||
Check 112 | 4204 Relay Module failure (Module 1) | ||||
Check 113 | 4204 Relay Module failure (Module 2) | ||||
Check 116 – 123 | Keypad failure. Last 2 digits are the address. (Example, Check 116 is a failure on address 16) | ||||
Check 128 | 5800TM Module failure | ||||
NO AC | AC Power Failure | ||||
BAT | Panel Battery Low | ||||
BAT xxx | Wireless zone low battery (where xxx is the zone number) | ||||
LB | Keyfob Low battery for Locally programmed Keyfob | ||||
Check 01 to 34 | Zone is not communicating with panel | ||||
Check 49 to 56 | Keyfobs are programmed incorrectly | ||||
D1 | System is in wait mode, system may have an internal problem | ||||
System Busy | System is in wait mode, system may have an internal problem | ||||
CA | Alarm was canceled, this is not a trouble | ||||
Canceled Alarm | Alarm was canceled, this is not a trouble | ||||
CC | Panel is being downloaded by Tech Support | ||||
Modem Comm | Panel is being downloaded by Tech Support | ||||
94 | Telephone Line Failure | ||||
Telco Fault | Telephone Line Failure | ||||
70 | Siren supervision failure | ||||
90 | RF Jam detected | ||||
00 Bat | Wireless keypad low battery | ||||
Cd | Phone test okay | ||||
dO | Dialer off | ||||
dd | Walk test is active (Code + 50 to enter / Code + 1 to exit) | ||||
dC | Download complete | ||||
dF | Download failed | ||||
E4 or E8 | More zones were programmed than wireless receiver is capable of using. | ||||
Alarm xxx | Zone is or was in alarm where xxx is the zone number | ||||
Fault xxx | Zone is faulted where xxx is the zone number | ||||
Check xxx | Zone is not communicating with the panel where xxx is the zone number | ||||
EA |
Exit Alarm, this is not a trouble, customer armed system then left and didn’t close door before delay expired |
||||
FC | Fail to Communicate | ||||
OC | Open Circuit, bad keypad wire | ||||
Beep every 40 sec |
System is in Test Mode (Press Code + 1 to exit) |